Luminex donor-specific crossmatches

被引:41
|
作者
Billen, E. V. A. [1 ]
Voorter, C. E. M. [1 ]
Christiaans, M. H. L. [2 ]
van den Berg-Loonen, E. M. [1 ]
机构
[1] Univ Hosp Maastricht, Tissue Typing Lab, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, Dept Internal Med, Maastricht, Netherlands
来源
TISSUE ANTIGENS | 2008年 / 71卷 / 06期
关键词
alloantibodies; HLA class I; HLA class II; kidney transplantation;
D O I
10.1111/j.1399-0039.2008.01032.x
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
In Luminex bead-based screening assays, color-coded microspheres coated with human leukocyte antigens (HLA) are used to identify both complement-binding and non-complement-binding HLA class I and II antibodies in recipient sera. Many laboratories rely on their specificity detection and use the information obtained for allocation of donor organs. A donor-specific crossmatch in the Luminex technique (LumXm) is for that reason desirable. A LumXm, in which the actual donor HLA are coated onto specific capture beads, was tested for 88 pre- and posttransplant sera of 18 recipients. The results were compared with previously published flow cytometric crossmatch (FCXm) results for the same donor-recipient combinations. All sera were also examined by Luminex single antigen (SA) tests. Class I LumXm detected 24 of 27 T-cell positive FCXm (89%) and class II 15 of 22 B-cell positive FCXm (68%). Sensitivity of LumXm for class I and II was 89% and 68% and specificity was 98% and 97%, respectively. Discrepant LumXm results were obtained in 13 sera of nine patients (15%). In general, based on SA testing, FCXm showed false-positive results for class I and LumXm gave false-negative and positive results for class II. The LumXm test was proven not to react with recipient sera containing DQ antibodies only, also DP detection was insufficient. The validity of the LumXm has been shown for class I, but its value for class II is uncertain. HLA-DR is most probably correctly identified, the validity for DQ and DP is doubtful.
引用
下载
收藏
页码:507 / 513
页数:7
相关论文
共 50 条
  • [1] Is it an interest for Luminex donor-specific crossmatches?
    Drouet, Mireille
    Tarnaud, Josiane
    Moudourou, Francois Belle
    Dickson, Sarah
    Rerolle, Jean Philippe
    Essig, Marie
    TISSUE ANTIGENS, 2009, 73 (05): : 458 - 459
  • [2] Class II donor-specific Luminex crossmatches
    Billen, E.
    Voorter, C.
    Christiaans, M.
    Van den Berg-Loonen, E.
    TISSUE ANTIGENS, 2008, 71 (04): : 290 - 291
  • [3] Correlation between Luminex donor-specific crossmatches and levels of donor-specific antibodies in pretransplantation screening
    Guillaume, N.
    Mazouz, H.
    Piot, V.
    Presne, C.
    Westeel, P. -F.
    TISSUE ANTIGENS, 2013, 82 (01): : 16 - 20
  • [4] LUMINEX DONOR-SPECIFIC CROSSMATCHES (LUMXM) AND DONOR-SPECIFIC ANTIBODY (DSA) DETERMINATION BY LUMINEX VS. CDC-CROSSMATCHES (CDC-XM) IN LIVING AND CADAVERIC KIDNEY TRANSPLANTATIONS
    Fylaktou, Asimina
    Sianou, Efrosini
    Lalaga, Soultana
    Persidou, Eleni
    Parapanisiou, Efthimia
    TISSUE ANTIGENS, 2012, 79 (06): : 510 - 510
  • [5] Donor-specific antibody detection: comparison of single antigen assay and Luminex crossmatches
    Caro-Oleas, J. L.
    Gonzalez-Escribano, M. F.
    Toro-Llamas, S.
    Acevedo, M. J.
    Martinez-Bravo, M. J.
    Aguilera, I.
    Nunez-Roldan, A.
    TISSUE ANTIGENS, 2010, 76 (05): : 398 - 403
  • [6] CLINICAL RELEVANCE OF LUMINEX DONOR-SPECIFIC CROSSMATCHES: DATA FROM 165 RENAL TRANSPLANTS
    Billen, Evy V. A.
    Christiaans, Maarten H. L.
    van den Berg-Loonen, Ella M.
    TRANSPLANT INTERNATIONAL, 2009, 22 : 131 - 131
  • [7] CLINICAL RELEVANCE OF LUMINEX DONOR-SPECIFIC CROSSMATCHES: DATA FROM 165 RENAL TRANSPLANTS
    Billen, Evy V. A.
    Christiaars, Maarten H. L.
    van den Berg-Loonen, Ella M.
    HUMAN IMMUNOLOGY, 2009, 70 : S164 - S164
  • [8] Clinical relevance of Luminex donor-specific crossmatches: data from 165 renal transplants
    Billen, E. V. A.
    Christiaans, M. H. L.
    van den Berg-Loonen, E. M.
    TISSUE ANTIGENS, 2009, 74 (03): : 205 - 212
  • [9] Clinical relevance of Luminex donor-specific crossmatches: data from 165 consecutive renal transplants
    Billen, Evy V. A.
    Christiaans, Maarten H. L.
    van den Berg-Loonen, Ella M.
    TISSUE ANTIGENS, 2009, 73 (05): : 418 - 418
  • [10] Donor-specific antibody detection by Luminex
    Boldt, B.
    Ladvienka, K.
    Clarke, M.
    Chance, S.
    TISSUE ANTIGENS, 2006, 67 (06): : 554 - 555