ISCEV standard for clinical electro-oculography (2010 update)

被引:95
|
作者
Marmor, Michael F. [1 ]
Brigell, Mitchell G. [2 ]
McCulloch, Daphne L. [3 ]
Westall, Carol A. [4 ,5 ]
Bach, Michael [6 ]
机构
[1] Stanford Univ, Sch Med, Eye Inst Stanford, Palo Alto, CA 94304 USA
[2] Novartis Inst Biomed Res, Cambridge, MA USA
[3] Glasgow Caledonian Univ, Glasgow G4 0BA, Lanark, Scotland
[4] Univ Toronto, Toronto, ON, Canada
[5] Hosp Sick Children, Toronto, ON M5G 1X8, Canada
[6] Univ Med Ctr Freiburg, Dept Ophthalmol, Freiburg, Germany
关键词
Arden ratio; ISCEV standards; Clinical electrophysiology; Electro-oculogram (EOG); Light adaptation; Retinal pigment epithelium (RPE); ELECTRORETINOGRAPHY;
D O I
10.1007/s10633-011-9259-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The clinical electro-oculogram (EOG) is an electrophysiological test of function of the outer retina and retinal pigment epithelium (RPE) in which changes in electrical potential across the RPE are recorded during successive periods of dark and light adaptation. This document presents the 2010 EOG Standard from the International Society for Clinical Electrophysiology of Vision (ISCEV: http://www.iscev.org). This revision has been reorganized and updated, but without changes to the testing protocol from the previous version published in 2006. It describes methods for recording the EOG in clinical applications and gives detailed guidance on technical requirements, practical issues, and reporting of results. It is intended to promote consistent quality of testing and reporting within and between clinical centers.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] ISCEV standard for clinical electro-oculography (2010 update)
    Michael F. Marmor
    Mitchell G. Brigell
    Daphne L. McCulloch
    Carol A. Westall
    Michael Bach
    Documenta Ophthalmologica, 2011, 122 : 1 - 7
  • [2] ISCEV Standard for clinical electro-oculography (2017 update)
    Constable, Paul A.
    Bach, Michael
    Frishman, Laura J.
    Jeffrey, Brett G.
    Robson, Anthony G.
    DOCUMENTA OPHTHALMOLOGICA, 2017, 134 (01) : 1 - 9
  • [3] ISCEV Standard for clinical electro-oculography (2017 update)
    Paul A. Constable
    Michael Bach
    Laura J. Frishman
    Brett G. Jeffrey
    Anthony G. Robson
    Documenta Ophthalmologica, 2017, 134 : 1 - 9
  • [4] Correction to: ISCEV Standard for clinical electro-oculography (2017 update)
    Paul A. Constable
    Michael Bach
    Laura J. Frishman
    Brett G. Jeffrey
    Anthony G. Robson
    Documenta Ophthalmologica, 2018, 136 : 155 - 155
  • [5] Erratum to: ISCEV Standard for clinical electro-oculography (2017 update)
    Paul A. Constable
    Michael Bach
    Laura J. Frishman
    Brett G. Jeffrey
    Anthony G. Robson
    Documenta Ophthalmologica, 2017, 134 : 155 - 155
  • [6] ISCEV Standard for Clinical Electro-oculography (EOG) 2006
    Malcolm Brown
    Michael Marmor
    Eberhard Vaegan
    Mitchell Zrenner
    Michael Brigell
    Documenta Ophthalmologica, 2006, 113 : 205 - 212
  • [7] ISCEV Standard for Clinical Electro-Oculography (EOG) 2006
    Brown, Malcolm
    Marmor, Michael
    Vaegan
    Zrenner, Eberhard
    Brigell, Mitchell
    Bach, Michael
    DOCUMENTA OPHTHALMOLOGICA, 2006, 113 (03) : 205 - 212
  • [8] ISCEV Standard for clinical electro-oculography (2017 update) (vol 134, pg 155, 2017)
    Constable, Paul A.
    Bach, Michael
    Frishman, Laura J.
    Jeffrey, Brett G.
    Robson, Anthony G.
    DOCUMENTA OPHTHALMOLOGICA, 2018, 136 (02) : 155 - 155
  • [9] ISCEV Standard for clinical electro-oculography (2017 update) (vol 134, pg 1, 2017)
    Constable, Paul A.
    Bach, Michael
    Frishman, Laura J.
    Jeffrey, Brett G.
    Robson, Anthony G.
    DOCUMENTA OPHTHALMOLOGICA, 2017, 134 (02) : 155 - 155
  • [10] CLINICAL ELECTRO-OCULOGRAPHY
    ALANKO, HI