Active Fixture with Passive Tuners for Full-Range Load-Pull Measurements

被引:0
|
作者
Halder, Subrata [1 ]
Hwang, James C. M. [1 ]
机构
[1] Lehigh Univ, Bethlehem, PA 18015 USA
关键词
Impedance matching; impedance measurement; microwave measurements; microwave power amplifiers; tuners;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The lossy cable in a conventional load-pull setup was replaced with an active fixture to realize full tuning range by using passive electromechanical tuners. The approach was validated in small-signal characterization of a through line up to the edge of the Smith chart, as well as large-signal characterization of a heterojunction bipolar transistor up to a voltage standing-wave ratio of 10:1. The approach is simpler than active load-pull setups and it significantly enhances the capabilities of conventional load-pull setups, especially in the characterization of high-power transistors with very low matching impedances.
引用
收藏
页码:85 / 88
页数:4
相关论文
共 50 条
  • [1] Load-pull tuners are frequency selective
    Tsironis, C
    Meierer, R
    MICROWAVES & RF, 2004, 43 (01) : 97 - +
  • [2] Prematching tuners advance load-pull testing
    Tsironis, C
    MICROWAVES & RF, 2000, 39 (03) : 139 - +
  • [3] SYSTEM PERFORMS ACTIVE LOAD-PULL MEASUREMENTS
    TSIRONIS, C
    MICROWAVES & RF, 1995, 34 (15) : 102 - &
  • [4] Harmonic tuners support accurate load-pull testing
    Tsironis, C
    Jurenas, A
    Liu, C
    MICROWAVES & RF, 2001, 40 (07) : 107 - +
  • [5] A New Technique for Decreasing the Characterization Time of Passive Load-Pull Tuners to Maximize Measurement Throughput
    Roff, Chris
    Graham, Joshua
    Sirois, Jerome
    Noori, Basim
    72ND ARFTG MICROWAVE MEASUREMENT SYMPOSIUM, 2008, : 92 - 96
  • [6] Behavioral Model Analysis of Active Harmonic Load-pull Measurements
    Woodington, S.
    Saini, R.
    Williams, D.
    Lees, J.
    Benedikt, J.
    Tasker, P. J.
    2010 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (MTT), 2010, : 1688 - 1691
  • [7] LOAD-PULL MEASUREMENTS OF DIFFERENTIAL AMPLIFIERS
    Koether, Dietmar
    Berben, Joerg
    67TH ARFTG MICROWAVE MEASUREMENTS CONFERENCE: MEASUREMENTS AND DESIGN OF HIGH POWER DEVICES AND SYSTEMS, 2007, : 229 - 233
  • [8] Load-pull tuners are frequency selective (vol 43, pg 97, 2004)
    Tsironis, C
    Meierer, R
    MICROWAVES & RF, 2004, 43 (02) : 108 - 108
  • [9] Enhancing Dynamic Range and Accuracy of Load-Pull Measurements by Using Prematched Transistors
    Ersoy, Erhan
    Bengtsson, Olof
    Heinrich, Wolfgang
    2015 GERMAN MICROWAVE CONFERENCE, 2015, : 307 - 310
  • [10] Software enhances automated load-pull measurements
    Driver, T
    MICROWAVES & RF, 1998, 37 (09) : 89 - +