Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder

被引:8
|
作者
Bilici, Meki [1 ]
Demir, Fikri [1 ]
Akin, Alper [1 ]
Ture, Mehmet [1 ]
Balik, Hasan [1 ]
Kuyumcu, Mahir [2 ]
机构
[1] Dicle Univ, Med Fac, Dept Pediat Cardiol, Diyarbakir, Turkey
[2] Dicle Univ, Med Fac, Dept Anesthesiol, Diyarbakir, Turkey
关键词
Patent ductus arteriosus; Children; Occlutech duct occluder; TERM-FOLLOW-UP; CLINICAL-EXPERIENCE; PREMATURE BABIES; INFANTS; MULTICENTER; DEVICE; PDA; KG;
D O I
10.1007/s00246-017-1702-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the feasibility, efficacy and safety of transcatheter closure of patent ductus arteriosus (PDA) with the Occlutech duct occluder (ODO) in children. We reviewed the clinical records of 71 patients who underwent percutaneous closure of PDA with an ODO between September 2014 and August 2016. The Occlutech duct occluder was applied to 71 patients during the study period (September 2014-August 2016), and the results were analyzed in this study. Forty-two of the patients were female and 29 male. The median age was 20.5 months (range, 6-194 months) and median weight was 16 kg (range, 6-68 kg). The PDA was classified as type A in 54 patients (76.1%), type E in 14 (19.7%), type C in 2 (2.8%) and type B in 1 (1.4%) based on the Krichenko classification. A standard ODO device was used for the transcatheter closure procedure in 66 patients and the long-shank ODO device in 5. In the echocardiographic measurement of PDA, the median smallest diameter was 2.7 mm (range, 1.5-7.0 mm), and in the angiographic measurement, the median smallest diameter was 2.5 mm (range, 1.5-6.5 mm). All 71 patients underwent successful PDA closure with the ODO. Angiography following the procedure showed complete closure in 47 patients (66.2%), mild residual shunt in 13 patients (18.3%) and a trivial shunt in 11 patients (15.5%). Color flow Doppler echocardiogpaphy at 24 h post-implantation showed that complete closure was achieved in 65 patients (91.5%), and 6 patients (8.5%) had mild residual shunt. All patients (100%) had complete closure at 30 days of follow-up. The results of this study showed that the Occlutech PDA occluder device is safe and effective in the closure of PDA. As the pulmonary artery side of the device is wider than the aortic side, protrusion toward the aortic side and embolization are prevented, but there is residual shunt in the early period, although this residual shunt disappeared after a few months.
引用
收藏
页码:1598 / 1605
页数:8
相关论文
共 50 条
  • [1] Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder
    Meki Bilici
    Fikri Demir
    Alper Akın
    Mehmet Türe
    Hasan Balık
    Mahir Kuyumcu
    [J]. Pediatric Cardiology, 2017, 38 : 1598 - 1605
  • [2] Is the new Occlutech duct occluder an appropriate device for transcatheter closure of patent ductus arteriosus?
    Godart, Francois
    Houeijeh, Ali
    Domanski, Olivia
    Guillaume, Marie-Paule
    Brard, Melanie
    Lucron, Hugues
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 261 : 54 - 57
  • [3] Transcatheter closure of patent ductus arteriosus with the Amplatzer Duct Occluder.
    Saliba, Z
    Aggoun, Y
    Hausse, AO
    Acar, P
    Bonnet, D
    Fraisse, A
    Sidi, D
    Kachaner, J
    Bonhoeffer, P
    [J]. ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 2000, 93 (05): : 533 - 538
  • [4] Transcatheter Closure of a Patent Ductus Arteriosus Using a Piccolo Duct Occluder
    Deb, Pranjit
    Benerjee, Anindya
    Som, Tapas
    Barik Sr, Ramachandra
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
  • [6] Transcatheter closure of patent ductus arteriosus in infants using the Amplatzer duct occluder
    Fischer, G
    Kramer, HH
    Uebing, A
    Renaud, C
    Grabitz, R
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 : 418 - 418
  • [7] Transcatheter closure of moderate to large patent ductus arteriosus with the amplatzer duct occluder
    Wang, Jou-Kou
    Wu, Mei-Hwan
    Hwang, Juey-Jen
    Chiang, Fu-Tein
    Lin, Ming-Tai
    Lue, Hung-Chi
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (04) : 572 - 578
  • [8] Transcatheter closure of patent ductus arteriosus using coils and Amplatzer duct occluder
    Dai, Z
    Zhang, Y
    Wang, H
    Jia, G
    Wang, H
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 164L - 165L
  • [9] Transcatheter Closure of Patent Ductus Arteriosus in Adults Using Amplatzer Duct Occluder
    Wang, Jou-Kou
    Wu, Mei-Hwan
    [J]. CIRCULATION, 2010, 122 (02) : E298 - E298
  • [10] Transcatheter closure of the patent ductus arteriosus using an amplatzer duct occluder in adults
    Lee, CH
    Leung, YL
    Chow, WH