Concurrent recording of AEP, SSEP and EEG parameters during anaesthesia:: a factor analysis

被引:7
|
作者
Schwilden, H
Kochs, E
Jeleazcov, C
Scheller, B
Schneider, G
Schüttler, J
Schwender, D
Stockmanns, G
Pöppel, E
机构
[1] Univ Erlangen Nurnberg, Anasthesiol Klin, Dept Anaesthesiol, D-91054 Erlangen, Germany
[2] Tech Univ Munich, Dept Anaesthesiol, D-8000 Munich, Germany
[3] Univ Munich, Dept Anaesthesiol, D-80539 Munich, Germany
[4] Univ Duisburg Essen, Dept Informat Technol, Essen, Germany
[5] Univ Munich, Dept Med Psychol, D-80539 Munich, Germany
关键词
factor analysis; monitoring; auditory evoked potentials; EEG; somatosensory evoked potentials;
D O I
10.1093/bja/aei113
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Spontaneous EEG, mid-latency auditory evoked potentials (AEP) and somatosensory evoked potentials (SSEP) have been used to monitor anaesthesia. This poses the question as to whether or not EEG, AEP and SSEP vary in parallel with varying conditions during surgical anaesthesia. Methods. A total of 81 variables (31 EEG, 22 SSEP, 28 AEP) were simultaneously recorded in 48 surgical patients during anaesthesia. A total of 307 cases of the 81 variables in stable anaesthetic states were recorded. A factor analysis was performed for this data set. Results. Sixteen variables were excluded because of multicollinearity. We extracted 13 factors with eigenvalues > 1, representing 78.3% of the total variance, from the remaining 65 x 307 matrix. The first three factors represented 12%, 11% and 10% of the total variance. Factor 1 had only significant loadings from EEG variables, factor 2 only significant loadings from AEP variables and factor 3 only significant loadings from SSEP variables. Conclusion. EEG, AEP and SSEP measure different aspects of neural processing during anaesthesia. This gives rise to the hypothesis that simultaneous monitoring of these quantities may give additional information compared with the monitoring of each quantity alone.
引用
收藏
页码:197 / 206
页数:10
相关论文
共 39 条
  • [1] On-line analysis of AEP and EEG for monitoring depth of anaesthesia
    Capitanio, L
    Jensen, EW
    Filligoi, GC
    Makovec, B
    Gagliardi, M
    Henneberg, SW
    Lindholm, P
    Cerutti, S
    METHODS OF INFORMATION IN MEDICINE, 1997, 36 (4-5) : 311 - 314
  • [2] Monotonic behaviour of an EEG-AEP based fuzzy logic index and BIS during decrease of anaesthesia
    Jordan, D.
    Kreuzer, M.
    Horn, B.
    Kochs, E. F.
    Schneider, G.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 62 - 62
  • [3] Monotonic behaviour of EEG-AEP based fuzzy logic index and BIS during decrease of anaesthesia
    Jordan, Denis
    Kreuzer, Matthias
    Omerovic, Adem
    Horn, Bettina
    Kochs, Eberhard F.
    Schneider, Gerhard
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 : S6 - S6
  • [4] Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging
    Thinh Nguyen
    Potter, Thomas
    Karmonik, Christof
    Grossman, Robert
    Zhang, Yingchun
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (136):
  • [5] Properties of the MEG-EEG signal recorded during anaesthesia with sevoflurane and dexmedetomidine compared to basal video-EEG recording
    Hernandez-Cera, C.
    Montesinos Fadrique, S. C.
    Clara, S.
    Rodiera, J.
    Russi, A.
    Nowak, R.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 171 - 171
  • [6] Comparison of bispectral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia
    Gajraj, RJ
    Doi, M
    Mantzaridis, H
    Kenny, GNC
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (05) : 672 - 678
  • [7] Prospective study comparing skin impedance with EEG parameters during the induction of anaesthesia with fentanyl and etomidate
    M Winterhalter
    S Münte
    M Gerhard
    O Danzeisen
    T Jüttner
    E Monaca
    L Hoy
    N Rahe-Meyer
    P Kienbaum
    European Journal of Medical Research, 15 (2)
  • [8] PROSPECTIVE STUDY COMPARING SKIN IMPEDANCE WITH EEG PARAMETERS DURING THE INDUCTION OF ANAESTHESIA WITH FENTANYL AND ETOMIDATE
    Winterhalter, M.
    Munte, S.
    Gerhard, M.
    Danzeisen, O.
    Juettner, T.
    Monaca, E.
    Hoy, L.
    Rahe-Meyer, N.
    Kienbaum, P.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 (02) : 47 - 53
  • [9] A unified canonical correlation analysis-based framework for removing gradient artifact in concurrent EEG/fMRI recording and motion artifact in walking recording from EEG signal
    Junhua Li
    Yu Chen
    Fumihiko Taya
    Julian Lim
    Kianfoong Wong
    Yu Sun
    Anastasios Bezerianos
    Medical & Biological Engineering & Computing, 2017, 55 : 1669 - 1681
  • [10] A unified canonical correlation analysis-based framework for removing gradient artifact in concurrent EEG/fMRI recording and motion artifact in walking recording from EEG signal
    Li, Junhua
    Chen, Yu
    Taya, Fumihiko
    Lim, Julian
    Wong, Kianfoong
    Sun, Yu
    Bezerianos, Anastasios
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (09) : 1669 - 1681