X-Ray Phase Contrast 3D Virtual Histology: Evaluation of Lung Alterations After Microbeam Irradiation

被引:2
|
作者
Romano, Mariele [1 ]
Bravin, Alberto [2 ,10 ]
Wright, Michael D. [3 ]
Jacques, Laurent [1 ]
Miettinen, Arttu [4 ,5 ,11 ]
Hlushchuk, Ruslan [6 ]
Dinkel, Julien [7 ]
Bartzsch, Stefan [8 ,9 ]
Laissue, Jean Albert [6 ]
Djonov, Valentin [6 ]
Coan, Paola [1 ,7 ]
机构
[1] Ludwig Maximilians Univ Munchen, Fac Phys, Garching, Germany
[2] European Synchrotron Radiat Facil, Grenoble, France
[3] Avail Med Devices, Roseville, CA USA
[4] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
[5] Paul Scherrer Inst, Swiss Light Source, Villigen, Switzerland
[6] Univ Bern, Inst Anat, Bern, Switzerland
[7] Ludwig Maximilians Univ Munchen, Fac Med, Dept Clin Radiol, Munich, Germany
[8] Tech Univ Munich, Sch Med, Dept Radiat Oncol, Klinikum Rechts Isar, Munich, Germany
[9] Helmholtz Ctr Munich, Inst Radiat Med, Munich, Germany
[10] Univ Milano Bicocca, Dept Phys, Milan, Italy
[11] Univ Jyvaskyla, Dept Phys, Jyvaskyla, Finland
关键词
RADIATION-THERAPY; SYNCHROTRON; MAMMOGRAPHY;
D O I
10.1016/j.ijrobp.2021.10.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study provides the first experimental application of multiscale 3-dimensional (3D) x-ray phase contrast imaging computed tomography (XPCI-CT) virtual histology for the inspection and quantitative assessment of the late-stage effects of radio-induced lesions on lungs in a small animal model. Methods and Materials: Healthy male Fischer rats were irradiated with x-ray standard broad beams and microbeam radiation therapy, a high-dose rate (14 kGy/s), FLASH spatially fractionated x-ray therapy to avoid beamlet smearing owing to cardiosynchronous movements of the organs during the irradiation. After organ dissection, ex vivo XPCI-CT was applied to all the samples and the results were quantitatively analyzed and correlated to histologic data. Results: XPCI-CT enables the 3D visualization of lung tissues with unprecedented contrast and sensitivity, allowing alveoli, vessel, and bronchi hierarchical visualization. XPCI-CT discriminates in 3D radio-induced lesions such as fibrotic scars and Ca/Fe deposits and allows full-organ accurate quantification of the fibrotic tissue within the irradiated organs. The radiation- induced fibrotic tissue content is less than 10% of the analyzed volume for all microbeam radiation therapy-treated organs and reaches 34% in the case of irradiations with 50 Gy using a broad beam. Conclusions: XPCI-CT is an effective imaging technique able to provide detailed 3D information for the assessment of lung pathology and treatment efficacy in a small animal model. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:818 / 830
页数:13
相关论文
共 50 条
  • [1] Laboratory-based x-ray phase-contrast tomography enables 3D virtual histology
    Toepperwien, Mareike
    Krenkel, Martin
    Quade, Felix
    Salditt, Tim
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS V, 2016, 9964
  • [2] 3D virtual histology of human pancreatic tissue by multiscale phase-contrast X-ray tomography
    Frohn, Jasper
    Pinkert-Leetsch, Diana
    Missbach-Guntner, Jeannine
    Reichardt, Marius
    Osterhoff, Markus
    Alves, Frauke
    Salditt, Tim
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1707 - 1719
  • [3] 3D virtual histology of rodent and primate cochleae with multi-scale phase-contrast X-ray tomography
    Schaeper, Jannis J.
    Kampshoff, Christoph A.
    Wolf, Bettina J.
    Roos, Lennart
    Michanski, Susann
    Ruhwedel, Torben
    Eckermann, Marina
    Meyer, Alexander
    Jeschke, Marcus
    Wichmann, Carolin
    Moser, Tobias
    Salditt, Tim
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [4] Advancing breast cancer diagnosis in 3D: The transformative power of X-ray phase-contrast microtomography for virtual histology
    Donato, S.
    Bonazza, D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 180
  • [5] Nucleus-specific X-ray stain for 3D virtual histology
    Mueller, Mark
    Kimm, Melanie A.
    Ferstl, Simone
    Allner, Sebastian
    Achterhold, Klaus
    Herzen, Julia
    Pfeiffer, Franz
    Busse, Madleen
    SCIENTIFIC REPORTS, 2018, 8
  • [6] Nucleus-specific X-ray stain for 3D virtual histology
    Mark Müller
    Melanie A. Kimm
    Simone Ferstl
    Sebastian Allner
    Klaus Achterhold
    Julia Herzen
    Franz Pfeiffer
    Madleen Busse
    Scientific Reports, 8
  • [7] X-ray grating-based phase tomography for 3D histology
    Zanette, Irene
    Weitkamp, Timm
    Le Duc, Geraldine
    Pfeiffer, Franz
    RSC ADVANCES, 2013, 3 (43): : 19816 - 19819
  • [8] Human lung virtual histology by multi-scale x-ray phase-contrast computed tomography
    Reichmann, Jakob
    Verleden, Stijn E.
    Kuehnel, Mark
    Kamp, Jan C.
    Werlein, Christopher
    Neubert, Lavinia
    Mueller, Jan-Hendrik
    Bui, Thanh Quynh
    Ackermann, Maximilian
    Jonigk, Danny
    Salditt, Tim
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [9] Integrating X-ray phase-contrast imaging and histology for comparative evaluation of breast tissue malignancies in virtual histology analysis
    Donato, Sandro
    Arana Pena, Lucia Mariel
    Arfelli, Fulvia
    Brombal, Luca
    Colmo, Luisella
    Longo, Renata
    Martellani, Fulvia
    Tromba, Giuliana
    Zanconati, Fabrizio
    Bonazza, Deborah
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [10] Integrating X-ray phase-contrast imaging and histology for comparative evaluation of breast tissue malignancies in virtual histology analysis
    Sandro Donato
    Lucia Mariel Arana Peña
    Fulvia Arfelli
    Luca Brombal
    Luisella Colmo
    Renata Longo
    Fulvia Martellani
    Giuliana Tromba
    Fabrizio Zanconati
    Deborah Bonazza
    Scientific Reports, 14