A model-based reconstruction method for 3-D Rotational Coronary Angiography

被引:2
|
作者
Xie, Lizhe [2 ,5 ]
Hu, Yining [2 ,5 ]
Nunes, Jean-Claude [3 ,4 ]
Bellanger, Jean-Jacques [3 ,4 ]
Bedossa, Marc [4 ,6 ]
Luo, Limin [2 ,5 ]
Toumoulin, Christine [1 ,3 ,4 ,5 ]
机构
[1] INSERM, French Natl Inst Hlth & Med Res, U642, F-35000 Rennes, France
[2] Southeast Univ, LIST, Nanjing, Peoples R China
[3] French Natl Inst Hlth & Med Res INSERM, U642, F-35000 Rennes, France
[4] Univ Rennes 1, Lab Traitement Signal & Image LTSI, F-35000 Rennes, France
[5] Ctr Rech & Informat Biomed Sino Francais LIA CRIB, F-35000 Rennes, France
[6] CHU Rennes, Intervent Cardiol Dept, F-35000 Rennes, France
关键词
X-RAY ANGIOGRAPHY; PROJECTION;
D O I
10.1109/IEMBS.2010.5627181
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a model-based reconstruction method of the coronary tree from a few number of projections in rotational angiography imaging. The reconstruction relies on projections acquired at a same cardiac phase and an energy function minimization that aims to lead the deformation of the 3D model to fit projection data whereas preserving coherence both in time and space. Some preliminary results are provided on simulated rotational angiograms.
引用
收藏
页码:3186 / 3189
页数:4
相关论文
共 50 条
  • [1] ECG Gated Tomographic reconstruction for 3-D Rotational Coronary Angiography
    Hu, Yining
    Xie, Lizhe
    Nunes, Jean Claude
    Bellanger, Jean Jacques
    Bedossa, Marc
    Toumoulin, Christine
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3614 - 3617
  • [2] MODEL-BASED 3-D RECONSTRUCTION OF BRANCHING VESSELS
    FESSLER, J
    NISHIMURA, D
    MACOVSKI, A
    [J]. IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 561 - 562
  • [3] Evaluation of Iterative Sparse Object Reconstruction From Few Projections for 3-D Rotational Coronary Angiography
    Hansis, Eberhard
    Schaefer, Dirk
    Doessel, Olaf
    Grass, Michael
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (11) : 1548 - 1555
  • [4] HIGH-SPEED ROTATIONAL ANGIOGRAPHY AND 3-D RECONSTRUCTION OF CORONARY SINUS IN CRT DEVICES IMPLANTATION
    Zubarev, E. I.
    Lebedev, D. S.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S142 - S143
  • [5] Quantitative Analysis of Deformable Model-Based 3-D Reconstruction of Coronary Artery From Multiple Angiograms
    Cong, Weijian
    Yang, Jian
    Ai, Danni
    Chen, Yang
    Liu, Yue
    Wang, Yongtian
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (07) : 1389 - 1400
  • [6] Quantitative Analysis of Deformable Model-Based 3-D Reconstruction of Coronary Artery From Multiple Angiograms
    Cong, Weijian
    Yang, Jian
    Ai, Danni
    Chen, Yang
    Liu, Yue
    Wang, Yongtian
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 2079 - 2090
  • [7] Nonseparable wavelet-based cone-beam reconstruction in 3-D rotational angiography
    Bonnet, S
    Peyrin, F
    Turjman, F
    Prost, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (03) : 360 - 367
  • [8] 3-D reconstruction of the coronary artery tree from multiple views of a rotational X-ray angiography
    Rui Liao
    Duong Luc
    Yiyong Sun
    Klaus Kirchberg
    [J]. The International Journal of Cardiovascular Imaging, 2010, 26 : 733 - 749
  • [9] 3-D reconstruction of the coronary artery tree from multiple views of a rotational X-ray angiography
    Liao, Rui
    Luc, Duong
    Sun, Yiyong
    Kirchberg, Klaus
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (07): : 733 - 749
  • [10] Deformable Known Component Model-Based Reconstruction for Coronary CT Angiography
    Zhang, X.
    Tilley, S.
    Xu, S.
    Mathews, A.
    McVeigh, E. R.
    Stayman, J. W.
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132