Ultrasound guidance for central venous catheter placement in Australasian emergency departments: Potential barriers to more widespread use

被引:13
|
作者
Matera, Jakub T. [1 ]
Egerton-Warburton, Diana [2 ]
Meek, Robert [3 ]
机构
[1] Frankston Hosp, Emergency Dept, Peninsula Hlth, Frankston, Vic 3199, Australia
[2] So Hlth, Monash Med Ctr, Clayton, Vic, Australia
[3] Dandenong Hosp, So Hlth, Dandenong, Vic, Australia
关键词
central venous catheter; emergency department; survey; ultrasound; JUGULAR-VEIN CATHETERIZATION; SUBCLAVIAN-VEIN; COMPLICATIONS; CANNULATION; TRIAL; PHYSICIANS; ATTITUDES; INTERNET; RATES; MAIL;
D O I
10.1111/j.1742-6723.2010.01347.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To survey Fellows of the Australasian College for Emergency Medicine (FACEMs) in order to describe current ultrasound (US) usage during central venous catheter (CVC) placement and to compare practice and opinions between FACEMs routinely using US and those not. Methods: Descriptive and analytical cross-sectional electronic survey of all FACEMs. Baseline variables including hospital type, US availability, frequency of CVC insertion, US usage and technique are presented descriptively. US practice and opinions on usage are compared between routine and non-routine users. Results: Responses were obtained from 486 (42.4%) of 1146 FACEMs emailed. Whereas 88.5% of respondents had US available and 70% had done an US course, only 37% routinely used US for CVC placement. Completion of an US course and performance of >11 CVC per year were strongly associated with routine US use (odds ratio 10.0 [5.5-18.4] and 2.6 [1.7-3.9], respectively). Common barriers to more frequent US use were not having completed an US course (20%) and US-guided CVC placement taking too long (18%). Eighty-five per cent of FACEMs agreed that there should be ED access to US and US training but only 34% thought its use should be mandatory. Conclusions: We found that only 37% of FACEM respondents routinely used US to guide placement of CVCs and a number of barriers to more frequent use are identified. Practices and opinions regarding US use differed significantly between routine and non-routine users.
引用
收藏
页码:514 / 523
页数:10
相关论文
共 50 条
  • [1] Use of ultrasound guidance in central venous catheter placement by emergency physicians in Saudi Arabia
    Al Aseri, Zohair A.
    Al Hussein, Reema M.
    Malabarey, Mohammed A.
    AlYahya, Bader A.
    Al Moaiqel, Faisal A.
    Al Ansari, Mariam A.
    Alrajhi, Khaled N.
    [J]. SAUDI MEDICAL JOURNAL, 2020, 41 (07) : 698 - 702
  • [2] Barriers to the use of ultrasound guidance in central venous catheter placement by emergency physicians in Saudi Arabia: a cross-sectional study
    Alhussein, Reema M.
    Alyahya, Bader A.
    Alashaikh, Abdulaziz S.
    Malabarey, Mohammed A.
    Alrajhi, Khaled N.
    Al Aseri, Zohair A.
    [J]. SIGNA VITAE, 2023, 19 (05) : 178 - 185
  • [3] Use of ultrasound for central venous catheter placement
    T Angelini
    L Bevilacqua
    F Forfori
    G Licitra
    L DeSimone
    F Giunta
    [J]. Critical Care, 12 (Suppl 2):
  • [4] Ultrasound guidance for central venous catheter placement: results from the Central Line Emergency Access Registry Database
    Balls, Adam
    LoVecchio, Frank
    Kroeger, Amy
    Stapczynski, J. Stephan
    Mulrow, Mary
    Drachman, David
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (05): : 561 - 567
  • [5] Decrease in central venous catheter placement due to use of ultrasound guidance for peripheral intravenous catheters
    Au, Arthur K.
    Rotte, Masashi J.
    Grzybowski, Robert J.
    Ku, Bon S.
    Fields, J. Matthew
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (09): : 1950 - 1954
  • [6] Development and Evaluation of a Program for the Use of Ultrasound for Central Venous Catheter Placement in a Pediatric Emergency Department
    Vieira, Rebecca L.
    Gallagher, Rachel A.
    Stack, Anne M.
    Werner, Heidi C.
    Levy, Jason A.
    [J]. PEDIATRIC EMERGENCY CARE, 2013, 29 (12) : 1245 - 1248
  • [7] Intra-thoracic placement of central venous catheter despite ultrasound guidance
    De Cassai, Alessandro
    Dal Cin, Stefano
    Bertini, Diana
    [J]. INTENSIVE CARE MEDICINE, 2018, 44 (12) : 2286 - 2287
  • [8] Placement of a Central Venous Catheter Into the Right Vertebral Artery Despite Ultrasound Guidance
    Lind, Robert C.
    Arvidsson, Bengt
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 58 (05) : 679 - 679
  • [9] Intra-thoracic placement of central venous catheter despite ultrasound guidance
    Alessandro De Cassai
    Stefano Dal Cin
    Diana Bertini
    [J]. Intensive Care Medicine, 2018, 44 : 2286 - 2287
  • [10] Implementation of a resident education program dramatically increases the use of ultrasound guidance for central venous catheter placement
    Parker, Kristen M.
    Stafford, Renae
    Mendes, Robert
    Park, Hyeon Ah
    Cairns, Bruce
    [J]. CRITICAL CARE MEDICINE, 2007, 35 (12) : A125 - A125