Acoustic method for quality control and in-service periodic monitoring of medium voltage cable terminations

被引:0
|
作者
Lundgaard, LE
Hansen, W
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The main part of outages in the distribution grid caused by cable terminations and joints has been preceded by a period with internal partial discharges. As a tool for condition based maintenance, a method for on-line periodic discharge measurement based on ultrasound detection of signals emitted from the discharges has been developed. The method has a sensitivity in the 5-50 pC range depending on the design of the termination.
引用
收藏
页码:130 / 133
页数:4
相关论文
共 50 条
  • [1] Evaluating medium voltage cable splices and terminations
    Taylor, B
    Morrison, G
    Welch, D
    [J]. PROCESS CONTROL, ELECTRICAL & INFORMATION CONFERENCE ISA PUPID 38TH ANNUAL SYMPOSIUM, 1998, : 155 - 164
  • [2] Evaluating medium voltage cable splices and terminations
    Taylor, B
    Morrison, G
    Welch, D
    [J]. INDUSTRY APPLICATIONS SOCIETY 44TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 1997, : 121 - 127
  • [3] Evaluating medium voltage cable splices and terminations
    Taylor, B
    Morrison, G
    [J]. CONFERENCE RECORD OF 2000 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 2000, : 188 - 194
  • [4] The application of on-line PDM on in-service MV cable terminations
    Chiu, Min-Yen
    Lee, Chang-Hsing
    Huang, Chih-Hsien
    Yen, Shih-Shong
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1171 - +
  • [5] Thermal Effects of High-Frequency Voltage on Medium Voltage Cable Terminations
    Banerjee, Sarajit
    Jayaram, Shesha H.
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 669 - 672
  • [6] IN-SERVICE VIDEO QUALITY MONITORING
    Ong, Ee Ping
    Wu, Shiqian
    Loke, Mei Hwan
    [J]. 2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 3381 - 3384
  • [7] Thermal Modeling of Medium Voltage Cable Terminations under Square Pulses
    Shaker, Yomna O.
    El-Hag, Ayman H.
    Patel, Utkarsh
    Jayaram, Shesha H.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 932 - 939
  • [8] Investigation of In-service Degradation of a Low Voltage PVC Cable
    Kapitany, Domonkos
    Csanyi, Gergely Mark
    Tamus, Zoltan Adam
    [J]. 2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 24 - 28
  • [9] Workmanship defect classification in medium voltage cable terminations with convolutional neural network
    Uckol, Halil Ibrahim
    Ilhan, Suat
    Ozdemir, Aydogan
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2021, 194
  • [10] Experiences with Continuous Condition Monitoring of In-Service MV Cable Connections
    van der Wielen, Peter C. J. M.
    Steennis, E. Fred
    [J]. 2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 1052 - 1059