Diagnostic Accuracy of Five Different Classification Systems for Thyroid Nodules A Prospective, Comparative Study

被引:11
|
作者
Orhan Soylemez, Umut Percem [1 ]
Gunduz, Nesrin [2 ]
机构
[1] Istanbul Medeniyet Univ, Goztepe City Hosp, Dept Radiol, Istanbul, Turkey
[2] Istanbul Medeniyet Univ, Fac Med, Goztepe City Hosp, Dept Radiol, Istanbul, Turkey
关键词
fine-needle aspiration biopsy; thyroid nodule; thyroid imaging reporting and data system; ultrasonography; RADIOLOGY TI-RADS; ASSOCIATION GUIDELINES; AMERICAN-COLLEGE; KOREAN SOCIETY; STRATIFICATION; MANAGEMENT; CANCER;
D O I
10.1002/jum.15802
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To compare the diagnostic performance of five different thyroid ultrasound classification systems, to determine which system is optimal for evaluating thyroid nodules and reducing the unnecessary biopsy rate. Methods In this prospective study, 1,010 nodules referred for biopsy during a 2-year period were classified using five classification systems: the Kwak Thyroid Imaging Reporting and Data System (Kwak TI-RADS), the European TI-RADS (EU TI-RADS, the Korean TI-RADS (K TI-RADS), the American College of Radiology TI-RADS (ACR TI-RADS), and the American Thyroid Association (ATA) classification. After fine needle aspiration biopsy, all classifications were compared for all nodules and also particularly for nodules sized 1-3 cm. Sensitivity, specificity, and interobserver agreement were evaluated for each classification system. Results Of the 939 nodules (after exclusion of Bethesda 3 nodules) finally classified according to the surgical histopathology and cytology results, 73 (7.8%) were malignant and 866 nodules were benign (92.2%). The sensitivity was highest (94.5%) for the ACR TI-RADS and lowest for the Kwak TI-RADS (69%). After exclusion of small (<1 cm) and large nodules (>3 cm); while sensitivity was highest for ATA (97.8%), ACR TI-RADS was the second best classification (91.3%). There was substantial agreement among all classification systems except the Kwak TI-RADS (fair agreement). Conclusions The ACR TI-RADS was the most sensitive ultrasound risk stratification system for all nodules, while the Kwak TI-RADS was the most specific, ie, the most capable of excluding benign nodules based on the combined cytological and histopathological results. ATA and ACR-TIRADS were the most sensitive classification systems for nodules 1 to 3 cm in size. The ACR TI-RADS had higher sensitivity than the Bethesda classification system when compared according to the histopathological results.
引用
收藏
页码:1125 / 1136
页数:12
相关论文
共 50 条
  • [1] Contrast Enhancement Ultrasound Improves Diagnostic Accuracy for Thyroid Nodules: A Prospective Multicenter Study
    Li, Jianming
    Dou, Jianping
    Li, Huarong
    Xiao, Fan
    Yu, Jie
    Xie, Mingxing
    Zhou, Ping
    Liang, Lei
    Zhou, Guiming
    Che, Ying
    Liu, Cun
    Cong, Zhibin
    Liu, Fangyi
    Han, Zhiyu
    Liang, Ping
    [J]. JOURNAL OF THE ENDOCRINE SOCIETY, 2023, 8 (01)
  • [2] Comparative study on the diagnostic values of different ultrasound technologies for malignant thyroid nodules
    Jin, Xiao-Zhu
    Lu, Wei-Wei
    Zhang, Hai-Feng
    Yan, Yuan-Yuan
    Gu, Xiao-Le
    [J]. ONCOLOGY LETTERS, 2018, 16 (01) : 910 - 914
  • [3] Comparison of Diagnostic Performance of Five Different Ultrasound TI-RADS Classification Guidelines for Thyroid Nodules
    Yang, Ruoning
    Zou, Xiuhe
    Zeng, Hao
    Zhao, Yunuo
    Ma, Xuelei
    [J]. FRONTIERS IN ONCOLOGY, 2020, 10
  • [4] Diagnostic Accuracy of a New Sonographic Classification System in Diagnosing Malignant Thyroid Nodules
    Amin, Muhammad
    Zahra, Mahwish
    Siddiqui, Mustafa Ali
    Kamal, Riffat
    Javed, Sahar
    Maqsood, Amena
    Khan, Mohammad Mohsin
    [J]. PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (06): : 1865 - 1867
  • [5] Diagnostic accuracy of different computer-aided diagnostic systems for malignant and benign thyroid nodules classification in ultrasound images A systematic review and meta-analysis protocol
    Liu, Ruisheng
    Li, Huijuan
    Liang, Fuxiang
    Yao, Liang
    Liu, Jieting
    Li, Meixuan
    Cao, Liujiao
    Song, Bing
    [J]. MEDICINE, 2019, 98 (29)
  • [6] Evaluation of the Nature of Thyroid Nodules by Duplex Ultrasound and Assessment of the Diagnostic Accuracy of TIRADS Classification
    Lampung, Nani
    Khalid, Saifullah
    Khalid, Mohd
    Rashid, Basmah Abdur
    Arif, Sayeedul Hasan
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (07) : TC01 - TC4
  • [7] Diagnostic accuracy of intraoperative frozen section in thyroid nodules
    Mollamehmetoglu, B.
    Livaoglu, A.
    Erdem, H.
    [J]. VIRCHOWS ARCHIV, 2016, 469 : S117 - S117
  • [8] Increasing diagnostic accuracy for thyroid nodules by an integrated multivariate approach: a methodological study
    Consorti, F.
    Cozza, V.
    Loponte, M.
    Mardente, S.
    Milazzo, F.
    Scardella, L.
    Antonaci, A.
    [J]. CLINICA TERAPEUTICA, 2011, 162 (01): : 31 - 35
  • [9] THE ASSOCIATION OF THE BETHESDA REPORTING SYSTEM AND THE AACE/ACE/AME US CLASSIFICATION SYSTEM FOR IMPROVING THE DIAGNOSTIC ACCURACY OF THYROID NODULES. AN INSTITUTIONAL PROSPECTIVE COHORT STUDY
    Orlando, Giuseppina
    Corigliano, Alessandro
    Mazzola, Sergio
    Vitale, Irene
    Guercio, Riccardo
    Dominici, Marco
    Carolla, Claudia
    Rotolo, Giulia
    Gullo, Roberto
    Carollo, Giuseppe
    [J]. ACTA MEDICA MEDITERRANEA, 2021, 37 (02): : 813 - 820
  • [10] German prospective multicenter study to compare different Thyroid Imaging Reporting and Data Systems (TIRADS) for the assessment of thyroid nodules
    Schenke, S.
    Seifert, P.
    Winkens, T.
    Zimny, M.
    Kreissl, M.
    Goerges, R.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S49 - S49