Modeling the instrument line shape of Fourier-transform spectrometers within the framework of partial coherence

被引:1
|
作者
Genest, J [1 ]
Tremblay, P [1 ]
机构
[1] Univ Laval, Dept Genie Elect & Genie Informat, Ctr Opt Photon & Laser, Quebec City, PQ G1K 7P4, Canada
关键词
D O I
10.1364/AO.44.003912
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The instrument line shape (ILS) of Fourier-transform spectrometers is modeled within a framework that enables us to take into account the partial coherence of optical fields. The cross spectral density and the angular coherence functions are used to develop a global ILS model including all possible geometric defects that can be introduced by a realistic two-beam interferometer. Tilt and shear no longer only reduce the modulation efficiency but are presented as contributors to the ILS. The case of an incoherent secondary planar source is covered and agrees with previously known results. However, it shows a coupling among tilt, shear, and optical path difference (OPD). A quasi-coherent source is also studied. Differences between the incoherent and the quasi-coherent cases are highlighted. The relative localization of the reference laser beam in the interferometer is shown to be of significance to provide a sampling scale that minimizes the OPD, or phase, induced by angular misalignment. (c) 2005 Optical Society of America.
引用
收藏
页码:3912 / 3924
页数:13
相关论文
共 50 条
  • [1] Radiometry in line-shape modeling of Fourier-transform spectrometers
    Desbiens, R
    Genest, J
    Tremblay, P
    [J]. APPLIED OPTICS, 2002, 41 (07) : 1424 - 1432
  • [2] Diffraction and line shape of Fourier-transform spectrometers
    Genest, J
    Tremblay, P
    [J]. APPLIED OPTICS, 2003, 42 (22) : 4541 - 4548
  • [3] RESOLUTION AND INSTRUMENT LINE-SHAPE EFFECTS ON SPECTRAL COMPENSATION WITH FOURIER-TRANSFORM INFRARED SPECTROMETERS
    ANDERSON, RJ
    GRIFFITHS, PR
    [J]. ANALYTICAL CHEMISTRY, 1978, 50 (13) : 1804 - 1811
  • [4] Impact of the optical aberrations on the line shape of Fourier-transform spectrometers
    Genest, J
    Tremblay, P
    [J]. VIBRATIONAL SPECTROSCOPY, 2002, 29 (1-2) : 3 - 13
  • [5] Matrix form for the instrument line shape of Fourier-transform spectrometers yielding a fast integration algorithm to theoretical spectra
    Desbiens, R
    Tremblay, P
    Genest, J
    Bouchard, JP
    [J]. APPLIED OPTICS, 2006, 45 (03) : 546 - 557
  • [6] Fast line-shape correction procedure for imaging Fourier-transform spectrometers
    Roy, Simon A.
    Potvin, Simon
    Genest, Jerome
    Desbiens, Raphaeel
    [J]. APPLIED OPTICS, 2007, 46 (21) : 4674 - 4679
  • [7] Instrument line-shape modeling and correction for off-axis detectors in Fourier-transform spectrometry
    Bowman, Kevin W.
    Worden, Helen M.
    Beer, Reinhard
    [J]. Applied Optics, 2000, 39 (21): : 3765 - 3773
  • [8] Instrument line-shape modeling and correction for off-axis detectors in Fourier-transform spectrometry
    Bowman, KW
    Worden, HM
    Beer, R
    [J]. APPLIED OPTICS, 2000, 39 (21) : 3765 - 3773
  • [9] CRYOGENICALLY COOLED FOURIER-TRANSFORM SPECTROMETERS
    HUPPI, RJ
    STEED, AJ
    HUPPI, ER
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 289 : 345 - 354
  • [10] Radiometric applications of fourier-transform spectrometers
    Chunnilall, CJ
    Fox, NP
    Theocharous, E
    [J]. MIKROCHIMICA ACTA, 1997, : 175 - 177