High-resolution in vivo imaging of peripheral nerves using optical coherence tomography: a feasibility study

被引:11
|
作者
Carolus, Anne E. [1 ]
Lenz, Marcel [2 ]
Hofmann, Martin [2 ]
Welp, Hubert [3 ]
Schmieder, Kirsten [1 ]
Brenke, Christopher [1 ]
机构
[1] Univ Hosp Knappschaftskrankenhaus Bochum, Dept Neurosurg, Bochum, Germany
[2] Ruhr Univ Bochum, Dept Photon & Terahertz Technol, Bochum, Germany
[3] Tech Hsch Georg Agr, Bochum, Germany
关键词
optical coherence tomography; peripheral nerve; nerve sheaths; high resolution; in vivo; texture analysis; TEXTURE; IMAGES; TECHNOLOGY;
D O I
10.3171/2019.2.JNS183542
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Because of their complex topography, long courses, and small diameters, peripheral nerves are challenging structures for radiological diagnostics. However, imaging techniques in the area of peripheral nerve diseases have undergone unexpected development in recent decades. They include MRI and high-resolution sonography (HRS). Yet none of those imaging techniques reaches a resolution comparable to that of histological sections. Fascicles are the smallest discernable structure. Optical coherence tomography (OCT) is the first imaging technique that is able to depict a nerve's ultrastructure at micrometer resolution. In the current study, the authors present an in vivo assessment of human peripheral nerves using OCT. METHODS OCT measurement was performed in 34 patients with different peripheral nerve pathologies, i.e., nerve compression syndromes. The nerves were examined during surgery after their exposure. Only the sural nerve was twice examined ex vivo. The Thorlabs OCT systems Callisto and Ganymede were used. For intraoperative use, a hand probe was covered with a sterile foil. Different postprocessing imaging techniques were applied and evaluated. In order to highlight certain structures, five texture parameters based on gray-level co-occurrence matrices were calculated according to Haralick. RESULTS The intraoperative use of OCT is easy and intuitive. Image artifacts are mainly caused by motion and the sterile foil. If the artifacts are kept at a low level, the hyporeflecting bundles of nerve fascicles and their inner parts can be displayed. In the Haralick evaluation, the second angular moment is most suitable to depict the connective tissue. CONCLUSIONS OCT is a new imaging technique that has shown promise in peripheral nerve surgery for particular questions. Its resolution exceeds that provided by recent radiological possibilities such as MRI and HRS. Since its field of view is relatively small, faster acquisition times would be highly desirable and have already been demonstrated by other groups. Currently, the method resembles an optical biopsy and can be a supplement to intraoperative sonography, giving high-resolution insight into a suspect area that has been located by sonography in advance.
引用
收藏
页码:1907 / 1913
页数:7
相关论文
共 50 条
  • [1] High-resolution imaging of the middle ear with optical coherence tomography - A feasibility study
    Pitris, C
    Saunders, KT
    Fujimoto, JG
    Brezinski, ME
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2001, 127 (06) : 637 - 642
  • [2] High-resolution in vivo nanoparticle imaging using magnetomotive optical coherence tomography
    Oldenburg, Amy L.
    Luo, Wei
    Boppart, Stephen A.
    [J]. Optical Molecular Probes for Biomedical Applications, 2006, 6097 : 9702 - 9702
  • [3] High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography
    Bouma, BE
    Tearney, GJ
    Compton, CC
    Nishioka, NS
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : 467 - 474
  • [4] High-resolution imaging of the thyroid gland using optical coherence tomography
    Pantanowitz, L
    Hsiung, PL
    Ko, TH
    Schneider, K
    Herz, PR
    Fujimoto, JG
    Raza, S
    Connolly, JL
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2004, 26 (05): : 425 - 434
  • [5] High-resolution imaging of gynecologic neoplasms using optical coherence tomography
    Pitris, C
    Goodman, A
    Boppart, SA
    Libus, JJ
    Fujimoto, JG
    Brezinski, ME
    [J]. OBSTETRICS AND GYNECOLOGY, 1999, 93 (01): : 135 - 139
  • [6] In vivo imaging of human peripheral nerves using optical coherence tomography compared to histopathology slices
    Moeller, J.
    Carolus, A. C.
    van de Nes, J. A. P.
    Lenz, M.
    Brenke, C.
    Schmieder, K.
    Welp, H.
    Gerhardt, N. C.
    Hofmann, M. R.
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXIV, 2020, 11228
  • [7] Feasibility of endovascular optical coherence tomography for high-resolution carotid vessel wall imaging
    Cheng, Kyle H. Y.
    Sun, Cuiru
    Cruz, Juan P.
    Marotta, Thomas R.
    Spears, Julian
    Montanera, Walter J.
    Herman, Peter R.
    Thind, Aman
    Courtney, Brian
    Standish, Beau A.
    Yang, Victor X. D.
    [J]. PHOTONIC THERAPEUTICS AND DIAGNOSTICS VIII, PTS 1 AND 2, 2012, 8207
  • [8] High-resolution coronary imaging by optical coherence tomography: Feasibility, pitfalls and artefact analysis
    Motreff, Pascal
    Levesque, Sebastien
    Souteyrand, Geraud
    Sarry, Laurent
    Ouchchane, Lemlih
    Citron, Bernard
    Cassagnes, Jean
    Lusson, Jean-Rene
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2010, 103 (04) : 215 - 226
  • [9] Feasibility of optical coherence tomography for high-resolution imaging of human gastrointestinal tract malignancies
    Costas Pitris
    Christine Jesser
    Stephen A. Boppart
    Debra Stamper
    Mark E. Brezinski
    James G. Fujimoto
    [J]. Journal of Gastroenterology, 2000, 35 : 87 - 92
  • [10] Feasibility of optical coherence tomography for high-resolution imaging of human gastrointestinal tract malignancies
    Pitris, C
    Jesser, C
    Boppart, SA
    Stamper, D
    Brezinski, ME
    Fujimoto, JG
    [J]. JOURNAL OF GASTROENTEROLOGY, 2000, 35 (02) : 87 - 92