Accuracy of intrapartum fetal blood gas analysis by scalp sampling A retrospective cohort study

被引:6
|
作者
Hilal, Ziad [1 ]
Mrkvicka, Jennifer [1 ]
Rezniczek, Guenther A. [1 ]
Dogan, Askin [1 ]
Tempfer, Clemens B. [1 ]
机构
[1] Ruhr Univ Bochum, Dept Obstet & Gynecol, Bochum, Germany
关键词
acidosis; cardiotocography; fetal blood gas analysis; fetal monitoring; fetal scalp sampling; PH; LABOR;
D O I
10.1097/MD.0000000000008839
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fetal blood gas analysis (FBGA) using scalp blood is commonly used to identify serious fetal distress. However, there is a lack of data regarding its accuracy and reliability. The aim of this studywas to determine the positive predictive value (PPV) and negative predictive value (NPV) of FBGA for predicting postpartum acidosis in case of nonreassuring fetal heart rate tracings (NRFHRT). To this end, we conducted a retrospective cohort study of singleton term deliveries with NRFHRT according to Federation Internationale de Gynecologie et d'Obstetrique and Fisher cardiotocography scores undergoing FBGA in a university hospital. The PPV and NPV of FBGA regarding neonatal acidosis (defined as a pH value <= 7.15 in arterial or venous umbilical cord blood) and Apgar scores indicating neonatal depression (defined as a 5-min Apgar score <= 5) were evaluated. Multivariate analysis was used to determine the influence of cardiotocography variations and the time delay between FBGAand delivery on the accuracy of FBGA. We analyzed 343 deliveries with NRFHRT. In 32 (9%) of these cases, fetal acidosis was confirmed by a postpartum umbilical cord blood pHvalue <7.15. In 308/343 (90%) cases, FBGA identified NRFHRT as false positive (as confirmed by nonacidotic postpartum pH values) and thus avoided unnecessary interventions such as operative delivery. The overall test accuracy ofFBGAwas 91%. FBGAaccurately predicted postpartum cord bloodpH values with amargin of +/- 0.2 in 319/343 (93%) cases. On the other hand, the false negative rate of FBGA was 8% (29/343). The PPV and NPV of FBGA for predicting postpartum acidosis were 50% and 91%, respectively. The sensitivity was 9% and the specificity was 99%. In a multivariate logistic regression analysis, maternal body mass index (odds ratio [OR] 1.1; 95% confidence interval [CI] 1.01-1.17; P=. 029) and cardiotocography variations (OR0.80; 95% CI 0.66-0.98; P=. 029) independently affected the predictive value of FBGA. ThePPV of FBGA regarding neonatal depression according to Apgar scores was low with only 17%. Weconclude that FBGA may be used in clinical practice to rule out, but not to rule in, neonatal acidosis in parturients with NRFHRT. It can avoid unnecessary interventions such as cesarean section or operative vaginal delivery in up to 90% of cases, but cannot reliably detect fetal acidosis.
引用
收藏
页数:6
相关论文
共 50 条
  • [2] INTRAPARTUM FETAL SURVEILLANCE - THE ROLE OF FETAL SCALP BLOOD-SAMPLING
    CLARK, SL
    PAUL, RH
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 153 (07) : 717 - 720
  • [3] Fetal scalp blood sampling - audit of NICE 2014 intrapartum guidelines
    Barratt, M.
    Chong, H. P.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 57 - 57
  • [4] Outcome of severe intrapartum acidemia diagnosed with fetal scalp blood sampling
    Holzmann, Malin
    Cnattingius, Sven
    Nordstrom, Lennart
    [J]. JOURNAL OF PERINATAL MEDICINE, 2011, 39 (05) : 545 - 548
  • [5] How to reduce fetal scalp blood sampling? A retrospective study evaluating the diagnostic value of scalp stimulation to predict fetal wellbeing assessed by scalp blood sampling
    Gilbert, M.
    Ghesquiere, L.
    Drumez, E.
    Subtil, D.
    Fague, V
    Berveiller, P.
    Garabedian, C.
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2021, 263 : 153 - 158
  • [6] Infant outcome at four years of age after intrapartum sampling of scalp blood lactate for fetal assessment. A cohort study
    Wiberg, Nana
    Klausen, Tobias Wirenfeldt
    Tyrberg, Tobias
    Nordstrom, Lennart
    Wiberg-Itzel, Eva
    [J]. PLOS ONE, 2018, 13 (03):
  • [7] Outcome in cases with severe intrapartum acidemia diagnosed with fetal scalp blood sampling
    Holzmann, Malin
    Cnattingius, Sven
    Nordstrom, Lennart
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2009, 201 (06) : S239 - S239
  • [8] Intrapartum assessment of fetal well-being: A comparison of scalp stimulation with scalp blood pH sampling
    Elimian, A
    Figueroa, R
    Tejani, N
    [J]. OBSTETRICS AND GYNECOLOGY, 1997, 89 (03): : 373 - 376
  • [9] Diagnostic accuracy of fetal scalp lactate for intrapartum acidosis compared with scalp pH
    Pascual Mancho, Jara
    Marti Gamboa, Sabina
    Redrado Gimenez, Olga
    Crespo Esteras, Raquel
    Rodriguez Solanilla, Belen
    Castan Mateo, Sergio
    [J]. JOURNAL OF PERINATAL MEDICINE, 2017, 45 (03) : 315 - 320
  • [10] FETAL SCALP BLOOD LACTATE AS AN INDICATOR OF INTRAPARTUM HYPOXIA
    SMITH, NC
    SOUTTER, WP
    SHARP, F
    MCCOLL, J
    FORD, I
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1983, 90 (09): : 821 - 831