Analysis of Wind Generator Operations under Unbalanced Voltage Dips in the Light of the Spanish Grid Code

被引:3
|
作者
Leon-Martinez, Vicente [1 ]
Montanana-Romeu, Joaquin [1 ]
机构
[1] Univ Politecn Valencia, Dept Elect Engn, Valencia 46022, Spain
来源
ENERGIES | 2011年 / 4卷 / 08期
关键词
reactive power; unbalanced three-phase systems; grid codes; wind energy; wind power generation; P-Q THEORY; 3-PHASE SYSTEMS; COMPONENTS;
D O I
10.3390/en4081148
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Operation of doubly fed induction generators subjected to transient unbalanced voltage dips is analyzed in this article to verify the fulfillment of the Spanish grid code. Akagi's p-q theory is not used for this study, because control of the electronic converter is not the main goal of the paper, but rather to know the physical phenomena involved in the wind turbine when voltage dips occur. Hence, the magnetizing reactive power of the induction generators and their components, which are related with the magnetic fields and determine operation of these machines, are expressed through the reactive power formulations established in the technical literature by three well-known approaches: the delayed voltage (DV) method, Czarnecki's Current's Physical Components (CPC) theory and Emanuel's approach. Non-fundamental and negative-sequence components of the magnetizing reactive power are respectively established to define the effects of the distortion and voltage imbalances on the magnetic fields and electromagnetic torques. Also, fundamental-frequency positive-sequence and negative-sequence reactive powers are decomposed into two components: due to the reactive loads and caused by the imbalances. This decomposition provides additional information about the effects of the imbalances on the main magnetic field and electromagnetic torque of the induction generator. All the above mentioned reactive powers are finally applied to one actual wind turbine subjected to a two-phase voltage dip in order to explain its operation under such transient conditions.
引用
收藏
页码:1148 / 1162
页数:15
相关论文
共 50 条
  • [1] Field tests of wind turbines submitted to real voltage dips under the new Spanish grid code requirements
    Gomez, E.
    Fuentes, J. A.
    Molina-Garcia, A.
    Ruz, F.
    Jimenez, F.
    [J]. WIND ENERGY, 2007, 10 (05) : 483 - 495
  • [2] A control strategy for converters of wind generator under unbalanced grid voltage
    Li, Xiao-Fan
    Gao, Chang-Ping
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2012, 40 (04): : 101 - 106
  • [3] Control and Protection of a DFIG-Based Wind Turbine under Unbalanced Grid Voltage Dips
    Zhou, Peng
    He, Yikang
    Sun, Dan
    Zhu, Jianguo
    [J]. 2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 2375 - +
  • [4] Ride-through of PMSG Wind Power System Under the Distorted and Unbalanced Grid Voltage Dips
    Sim, Jun-Bo
    Kim, Ki-Cheol
    Son, Rak-Won
    Oh, Joong-Ki
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (06) : 898 - 904
  • [5] Rotor voltage analysis of doubly fed induction generator under unsymmetrical grid voltage dips
    Zhang, Lu
    Jin, Xinmi
    Zhan, Liangyu
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (14): : 136 - 142
  • [6] Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    Brekken, Ted K. A.
    Mohan, Ned
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 129 - 135
  • [7] Validation of a DFIG wind turbine model submitted to two-phase voltage dips following the Spanish grid code
    Jimenez, Francisco
    Gomez-Lazaro, Emilio
    Alvaro Fuentes, Juan
    Molina-Garcia, Angel
    Vigueras-Rodriguez, Antonio
    [J]. RENEWABLE ENERGY, 2013, 57 : 27 - 34
  • [8] Results using different reactive power definitions for wind turbines submitted to voltage dips:: Application to the Spanish grid code
    Gomez, Emilio
    Alvaro Fuentes, Juan
    Jimenez, Francisco
    [J]. 2006 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION. VOLS 1-5, 2006, : 768 - +
  • [9] Control of grid-side converter of direct-drive wind power system under unbalanced voltage dips
    Zhu, Lin
    Xu, Dianguo
    Ma, Hongfei
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (SUPPL. 1): : 101 - 106
  • [10] Robust Current Control of Doubly Fed Wind Turbine Generator under Unbalanced Grid Voltage Conditions
    Wang, Yun
    Gong, Wenming
    Wu, Qiuwei
    [J]. 2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,