Simulation and Comparison of Heating and Cooling Load between a Zero-Energy Building and a Common Building in Severe Cold Region

被引:7
|
作者
Li, Huixing [1 ]
Zhang, Ran [1 ]
Feng, Guohui [1 ]
Huang, Kailiang [1 ]
Cao, Chihong [1 ]
机构
[1] Shenyang Jianzhu Univ, Shenyang 110168, Peoples R China
关键词
Zero energy building; DeST; Energy saving;
D O I
10.1016/j.proeng.2015.09.077
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to grasp the energy-saving potential of air conditioning system in severe cold region, choosing a nearly zero energy consumption building in Shenyang of China as research object. The concepts of green building and passive building, and many building energy efficiency technology such as phase change energy storage, exhaust air heat recovery, tunnel wind, low-e glass, outside wall insulation, are used in the process. Using the DeST software to establish a physical model and though simulating the heating and cooling load of building air conditioning system to research the Air conditioning system load variation and influencing factors and compare with the same type of conventional building energy consumption. Nearly zero energy consumption building's winter heating load has reduced 73.72% compared with the common building, and the comprehensive energy saving rate is up to 55.22%. The air conditioning system has great energy saving potential. (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:1505 / 1509
页数:5
相关论文
共 50 条
  • [1] A Solar Heating and Cooling System in a Nearly Zero-Energy Building: A Case Study in China
    Sun, Zhifeng
    Zhao, Yaohua
    Xu, Wei
    Zhang, Xinyu
    Li, Huai
    Wang, Min
    He, Tao
    Wang, Dongxu
    [J]. INTERNATIONAL JOURNAL OF PHOTOENERGY, 2017, 2017
  • [2] Comprehensive evaluation and analysis of a nearly zero-energy building heating system using a multi-source heat pump in severe cold region
    Zhang, Lei
    Feng, Guohui
    Li, Ainong
    Huang, Kailiang
    Chang, Shasha
    [J]. BUILDING SIMULATION, 2023, 16 (10) : 1949 - 1970
  • [3] Comprehensive evaluation and analysis of a nearly zero-energy building heating system using a multi-source heat pump in severe cold region
    Lei Zhang
    Guohui Feng
    Ainong Li
    Kailiang Huang
    Shasha Chang
    [J]. Building Simulation, 2023, 16 : 1949 - 1970
  • [4] Development of Experimental Load Management System for Nearly Zero-Energy Building
    Maask, Vahur
    Rosin, Argo
    Roasto, Indrek
    [J]. 2018 IEEE 59TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON), 2018,
  • [5] Thermal and energy performance of a nearly zero-energy building in Mediterranean climate: the gap between designed and monitored loads of space heating and cooling systems
    Ascione, Fabrizio
    De Masi, Rosa Francesca
    Festa, Valentino
    Gigante, Antonio
    Ruggiero, Silvia
    Vanoli, Giuseppe Peter
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (01) : 732 - 747
  • [6] Comparison of the environmental, energy, and thermal comfort performance of air and radiant cooling systems in a zero-energy office building in Singapore
    Li, Jiayu
    Pantelic, Jovan
    Merchant, Coleman B.
    Chen, Kian Wee
    Izuhara, Ippei
    Yuki, Ryosuke
    Meggers, Forrest M.
    Schiavon, Stefano
    [J]. ENERGY AND BUILDINGS, 2024, 318
  • [7] Energy analysis for construction of a zero-energy residential building using thermal simulation in Iran
    Amani, Nima
    Reza Soroush, Abdul Amir
    Moghadas Mashhad, Mostafa
    Safarzadeh, Keyvan
    [J]. INTERNATIONAL JOURNAL OF ENERGY SECTOR MANAGEMENT, 2021, 15 (05) : 895 - 913
  • [8] Cooling system energy flexibility of a nearly zero-energy office building using building thermal mass: Potential evaluation and parametric analysis
    Lu, Fei
    Yu, Zhenyu
    Zou, Yu
    Yang, Xudong
    [J]. ENERGY AND BUILDINGS, 2021, 236
  • [9] HEATING/COOLING/POWER LOAD CHARACTERISTICS IN CHINA'S SEVERE COLD REGION
    Zhao Jianing
    Wen Xin
    [J]. BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 2155 - 2162
  • [10] Identification of cyber-attack/outage/fault in zero-energy building with load and energy management strategies
    Hemmati, Reza
    Faraji, Hossien
    [J]. JOURNAL OF ENERGY STORAGE, 2022, 50