Influence of polyetheretherketone coatings on the Ti-13Nb-13Zr titanium alloy's bio-tribological properties and corrosion resistance

被引:43
|
作者
Sak, Anita [1 ]
Moskalewicz, Tomasz [1 ]
Zimowski, Slawomir [2 ]
Cieniek, Lukasz [1 ]
Dubiel, Beata [1 ]
Radziszewska, Agnieszka [1 ]
Kot, Marcin [2 ]
Lukaszczyk, Alicja [3 ]
机构
[1] AGH Univ Sci & Technol, Fac Met Engn & Ind Comp Sci, Czarnowiejska 66, PL-30054 Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Mech Engn & Robot, Mickiewicza 30, PL-30059 Krakow, Poland
[3] AGH Univ Sci & Technol, Fac Foundry Engn, Reymonta 23, PL-30059 Krakow, Poland
关键词
Surface modification; Biomaterials; Wear resistance; Lubricated contact; Corrosion resistance; Ringer's solution; ELECTROPHORETIC DEPOSITION; MECHANICAL-PROPERTIES; SLIDING FRICTION; PEEK COMPOSITE; WEAR BEHAVIOR; MICROSTRUCTURE; TI-6AL-4V; HARDNESS; SURFACE; CARBON;
D O I
10.1016/j.msec.2016.02.043
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Polyetheretherketone (PEEK) coatings of 70-90 mu m thick were electrophoretically deposited from a suspension of PEEK powder in ethanol on near-beta Ti-13Nb-13Zr titanium alloy. In order to produce good quality coatings, the composition of the suspension (pH) and optimized deposition parameters (applied voltage and time) were experimentally selected. The as-deposited coatings exhibited the uniform distribution of PEEK powders on the substrate. The subsequent annealing at a temperature above the PEEK melting point enabled homogeneous, semi-crystalline coatings with spherulitic morphology to be produced. A micro-scratch test showed that the coatings exhibited very good adhesion to the titanium alloy substrate. Coating delamination was not observed even up to a maximal load of 30 N. The PEEK coatings significantly improved the tribological properties of the Ti-13Nb-13Zr alloy. The coefficient of friction was reduced from 0.55 for an uncoated alloy to 0.40 and 0.12 for a coated alloy in a dry sliding and sliding in Ringer's solution, respectively. The PEEK coatings exhibited excellent wear resistance in both contact conditions. Their wear rate was more than 200 times smaller compared with the wear rate of the uncoated Ti-13Nb-13Zr alloy. The obtained results indicate that electrophoretically deposited PEEK coatings on the near-beta titanium alloy exhibit very useful properties for their prospective tribological applications in medicine. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 61
页数:10
相关论文
共 50 条
  • [1] Influence of hydroxyapatite on the corrosion resistance of the Ti-13Nb-13Zr alloy
    Duarte, Lais T.
    Biaggio, Sonia R.
    Rocha-Filho, Romeu C.
    Bocchi, Nerilso
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 (05) : 1009 - 1015
  • [2] Influence of hydroxyapatite on the corrosion resistance of the Ti-13Nb-13Zr alloy
    Laís T. Duarte
    Sonia R. Biaggio
    Romeu C. Rocha-Filho
    Nerilso Bocchi
    [J]. Journal of Materials Science: Materials in Medicine, 2009, 20 : 1009 - 1015
  • [3] Electrophoretic Deposition, Microstructure, and Corrosion Resistance of Porous Sol–Gel Glass/Polyetheretherketone Coatings on the Ti-13Nb-13Zr Alloy
    Tomasz Moskalewicz
    Anita Zych
    Alicja Łukaszczyk
    Katarzyna Cholewa-Kowalska
    Adam Kruk
    Beata Dubiel
    Agnieszka Radziszewska
    Katarzyna Berent
    Marta Gajewska
    [J]. Metallurgical and Materials Transactions A, 2017, 48 : 2660 - 2673
  • [4] Electrophoretic Deposition, Microstructure, and Corrosion Resistance of Porous Sol-Gel Glass/Polyetheretherketone Coatings on the Ti-13Nb-13Zr Alloy
    Moskalewicz, Tomasz
    Zych, Anita
    Lukaszczyk, Alicja
    Cholewa-Kowalska, Katarzyna
    Kruk, Adam
    Dubiel, Beata
    Radziszewska, Agnieszka
    Berent, Katarzyna
    Gajewska, Marta
    [J]. METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2017, 48A (05): : 2660 - 2673
  • [5] Electrophoretic Deposition, Microstructure and Selected Properties of Composite Alumina/Polyetheretherketone Coatings on the Ti-13Nb-13Zr Alloy
    Moskalewicz, Tomasz
    Zimowski, Slawomir
    Zych, Anita
    Lukaszczyk, Alicja
    Reczynska, Katarzyna
    Pamula, Elzbieta
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (03) : D116 - D128
  • [6] The corrosion resistance in artificial saliva of titanium and Ti-13Nb-13Zr alloy processed by high pressure torsion
    Barjaktarevic, Dragana
    Bajat, Jelena
    Cvijovic-Alagic, Ivana
    Dimic, Ivana
    Hohenwarter, Anton
    Dokic, Veljko
    Rakin, Marko
    [J]. ECF22 - LOADING AND ENVIRONMENTAL EFFECTS ON STRUCTURAL INTEGRITY, 2018, 13 : 1834 - 1839
  • [7] Influence of Two-Stage Anodization on Properties of the Oxide Coatings on the Ti-13Nb-13Zr Alloy
    Ossowska, Agnieszka
    Zielinski, Andrzej
    Olive, Jean-Marc
    Wojtowicz, Andrzej
    Szweda, Piotr
    [J]. COATINGS, 2020, 10 (08)
  • [8] Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy
    Geetha, M
    Mudali, UK
    Gogia, AK
    Asokamani, R
    Raj, B
    [J]. CORROSION SCIENCE, 2004, 46 (04) : 877 - 892
  • [9] Corrosion behavior of Ti-13Nb-13Zr alloy used as a biomaterial
    Niemeyer, T. C.
    Grandini, C. R.
    Pinto, L. M. C.
    Angelo, A. C. D.
    Schneider, S. G.
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2009, 476 (1-2) : 172 - 175
  • [10] Wear and corrosion behavior of oxygen implanted biomedical titanium alloy Ti-13Nb-13Zr
    Mohan, L.
    Anandan, C.
    [J]. APPLIED SURFACE SCIENCE, 2013, 282 : 281 - 290