Neutronic analysis of ITER neutral beam test bed

被引:6
|
作者
Loughlin, MJ [1 ]
机构
[1] UKAEA Fus, Culham Sci Ctr, Abingdon OX14 1PR, Oxon, England
关键词
D O I
10.1016/j.fusengdes.2005.06.163
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The neutron dose arising during the operation of the ITER neutral beam test bed was calculated using the Monte-Carlo code MCNP. The activation of the injector components was determined using the inventory code FISPACT and the resultant gamma ray doses at the end of the test programme were determined. It is found that there would be a neutron dose during beam operations sufficient to entail restricted and monitored access to areas outside the shield wall. A careful assessment of the shielding is needed. The individual components of the injector are generally not activated excessively, i.e. their activation levels fall below the hands on limit within 1 year. However, the total gamma dose close to the vessel is substantially higher than any individual contact dose. This must be taken into consideration in maintenance planning. (c) 2005 EURATOM/UKAEA. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [1] NEUTRONIC ANALYSES FOR THE UPPER PORTS IN THE NEUTRAL BEAM CELL OF ITER
    Serikov, A.
    Fischer, U.
    Grosse, D.
    Loughlin, M. J.
    Majerle, M.
    Schreck, S.
    Spaeh, P.
    Strauss, D.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 60 (02) : 708 - 714
  • [2] Diagnostics of the ITER neutral beam test facility
    Pasqualotto, R.
    Serianni, G.
    Sonato, P.
    Agostini, M.
    Brombin, M.
    Croci, G.
    Dalla Palma, M.
    De Muri, M.
    Gazza, E.
    Gorini, G.
    Pomaro, N.
    Rizzolo, A.
    Spolaore, M.
    Zaniol, B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [3] Progress in the ITER neutral beam test facility
    Toigo, V
    Dal Bello, S.
    Bigi, M.
    Boldrin, M.
    Chitarin, G.
    Grando, L.
    Luchetta, A.
    Marcuzzi, D.
    Pasqualotto, R.
    Pomaro, N.
    Serianni, G.
    Zaccaria, P.
    Zanotto, L.
    Agostinetti, P.
    Agostini, M.
    Antoni, V
    Aprile, D.
    Barbisan, M.
    Battistella, M.
    Brombin, M.
    Cavazzana, R.
    Dalla Palma, M.
    Dan, M.
    Denizeau, S.
    De Lorenzi, A.
    Delogu, R.
    De Muri, M.
    Fadone, M.
    Fellin, F.
    Ferro, A.
    Fiorentin, A.
    Gaio, E.
    Gambetta, G.
    Gasparini, F.
    Gnesotto, F.
    Jain, P.
    Maistrello, A.
    Manduchi, G.
    Manfrin, S.
    Marchiori, G.
    Marconato, N.
    Moresco, M.
    Ocello, E.
    Patton, T.
    Pavei, M.
    Peruzzo, S.
    Pilan, N.
    Pimazzoni, A.
    Piovan, R.
    Poggi, C.
    NUCLEAR FUSION, 2019, 59 (08)
  • [4] Comparative analysis of two electric schemes for the ion source power supplies of the ITER neutral beam injector test bed
    Toigo, V.
    Gaio, E.
    Milani, F.
    21ST IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING - SOFE 05, 2006, : 421 - 424
  • [5] Tritium monitoring in the ITER neutral beam test facility
    Loughlin, M. J.
    Lawrence, G.
    FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) : 646 - 651
  • [6] Maintenance schemes for the ITER neutral beam test facility
    Zaccaria, P
    Dal Bello, S
    Marcuzzi, D
    Masiello, A
    Cordier, JJ
    Hemsworth, R
    Antipenkov, A
    Day, C
    Dremel, M
    Mack, A
    Jones, T
    Coniglio, A
    Pillon, M
    Sandri, S
    Speth, E
    Tanga, A
    Antoni, V
    Di Pietro, E
    Mondino, PL
    FUSION ENGINEERING AND DESIGN, 2005, 74 (1-4) : 255 - 259
  • [7] Safety systems in the ITER neutral beam test facility
    Dal Bello, Samuele
    Battistella, Manuela
    Grando, Luca
    Luchetta, Adriano
    Moressa, Modesto
    Breda, Mauro
    Svensson, Lennart
    Paolucci, Francesco
    Labate, Carmelo Vincenzo
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 246 - 249
  • [8] Neutronic analysis for bolometers in ITER
    Suarez, A.
    Reichle, R.
    Loughlin, M.
    Polunovskiy, E.
    Walsh, M.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 1395 - 1399
  • [9] An Indian test facility to characterise diagnostic neutral beam for ITER
    Singh, M. J.
    Bandyopadhyay, M.
    Rotti, C.
    Singh, N. P.
    Shah, Sejal
    Bansal, G.
    Gahlaut, A.
    Soni, J.
    Lakdawala, H.
    Waghela, Harshad
    Ahmed, I.
    Roopesh, G.
    Baruah, U. K.
    Chakraborty, A. K.
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 732 - 735
  • [10] EPICS - MDSplus integration in the ITER Neutral Beam Test Facility
    Luchetta, Adriano
    Manduchi, Gabriele
    Barbalace, Antonio
    Soppelsa, Anton
    Taliercio, Cesare
    FUSION ENGINEERING AND DESIGN, 2011, 86 (6-8) : 1252 - 1255