Screening of microplastics in water and sludge lines of a drinking water treatment plant in Catalonia, Spain

被引:33
|
作者
Dronjak, Lara [1 ]
Exposito, Nora [1 ]
Rovira, Joaquim [1 ,2 ]
Florencio, Karin [4 ]
Emiliano, Pere [5 ]
Corzo, Beatriz [4 ]
Schuhmacher, Marta [1 ]
Valero, Fernando [5 ]
Sierra, Jordi [3 ]
机构
[1] Univ Rovira & Virgili, Dept Chem Engn, Environm Engn Lab, Paisos Catalans Ave 26, Tarragona 43007, Catalonia, Spain
[2] Univ Rovira & Virgili, IISPV, Sch Med, Lab Toxicol & Environm Hlth, St Llorenc 21, Reus 43201, Catalonia, Spain
[3] Univ Barcelona, Fac Pharm, Joan XXIII Ave S-N, Barcelona 08028, Catalonia, Spain
[4] Sorigue Grp, Ronda Guinardo 99, Barcelona 08041, Catalonia, Spain
[5] Ens Abastament Aigua Ter Llobregat ATL, St Marti Erm 30, Sant Joan Despi 08970, Barcelona, Spain
关键词
Plastic pollution; Drinking water; Sludge; Removal ratios; WASTE-WATER; MONITORING MICROPLASTICS; HUMAN HEALTH; IDENTIFICATION; REMOVAL; FIBERS; COAGULATION; PARTICLES; EXPOSURE; THREAT;
D O I
10.1016/j.watres.2022.119185
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microplastics (MPs) are emerging pollutants detected everywhere in the environment, with the potential to harm living organisms. The present study investigated the concentration, morphology, and composition of MPs, between 20 mu m and 5 mm, in a drinking water treatment plant (DWTP) located close to Barcelona (Catalonia, NE Spain). The sampling included different units of the DWTP, from influent to effluent as well as sludge line. Sampling strategy, filtration, allows sampling of large volumes of water avoiding sample contamination, and during 8 h in order to increase the representativeness of MPs collected. The pre-treatment of the samples consisted of advanced oxidation with Fenton's reagent and hydrogen peroxide, followed by density separation of the particles with zinc chloride solution. Visual identification was performed with an optical and stereoscopic microscope with final Fourier-transform infrared spectroscopic (FTIR) confirmation. MPs were found in all DWTP samples, with concentrations from 4.23 +/- 1.26 MPs/L to 0.075 +/- 0.019 MPs/L in the influent and effluent of the plant, respectively. The overall removal efficiency of the plant was 98.3%. The most dominant morphology was fibers followed by fragments and films. Twenty-two different polymer types were identified and synthetic cellulose, polyester, polyamide, polypropylene, polyethylene, polyurethane, and polyacrylonitrile were the most common. Although MPs could be incorporated from the distribution network, MPs intake from drinking water from this DWTP was not an important route compared to fish and seafood ingestion.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Microplastics from headwaters to tap water: occurrence and removal in a drinking water treatment plant in Barcelona Metropolitan area (Catalonia, NE Spain)
    Joan Dalmau-Soler
    Rubèn Ballesteros-Cano
    Mª Rosa Boleda
    Miquel Paraira
    Núria Ferrer
    Silvia Lacorte
    Environmental Science and Pollution Research, 2021, 28 : 59462 - 59472
  • [2] Microplastics from headwaters to tap water: occurrence and removal in a drinking water treatment plant in Barcelona Metropolitan area (Catalonia, NE Spain)
    Dalmau-Soler, Joan
    Ballesteros-Cano, Ruben
    Boleda, Ma Rosa
    Paraira, Miquel
    Ferrer, Nuria
    Lacorte, Silvia
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (42) : 59462 - 59472
  • [3] Radioactivity evaluation of Ebro river water and sludge treated in a potable water treatment plant located in the South of Catalonia (Spain)
    Palomo, M.
    Penalver, A.
    Aguilar, C.
    Borrull, F.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (03) : 474 - 480
  • [4] Natural radioactivity in drinking water in Catalonia (Spain)
    Ortega, X
    Valles, I
    Serrano, I
    ENVIRONMENT INTERNATIONAL, 1996, 22 : S347 - S354
  • [5] Microplastics control in drinking water in Spain and theUE
    Galvin, Rafael Marin
    REVISTA DE SALUD AMBIENTAL, 2024, 24 (01) : 125 - 138
  • [6] Occurrence and removal of microplastics in an advanced drinking water treatment plant (ADWTP)
    Wang, Zhifeng
    Lin, Tao
    Chen, Wei
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 700
  • [7] Microplastics removal efficiency of drinking water treatment plant with pulse clarifier
    Sarkar, Dhruba Jyoti
    Sarkar, Soma Das
    Das, Basanta Kumar
    Praharaj, Jaya Krushna
    Mahajan, Dev Kumar
    Purokait, Bidesh
    Mohanty, Trupty Rani
    Mohanty, Debasmita
    Gogoi, Pranab
    Kumar, V. Santhana
    Behera, Bijay Kumar
    Manna, Ranjan Kumar
    Samanta, Srikanta
    JOURNAL OF HAZARDOUS MATERIALS, 2021, 413
  • [8] Water Supply and Drinking Water Treatment in Spain
    Osca Verdegal, Alexis F.
    Domokosova, Katarina
    COLLOQUIUM ON LANDSCAPE MANAGEMENT 2011, 2011, : 54 - 58
  • [9] Occurrence and health risk assessment of PFAS and possible precursors: a case study in a drinking water treatment plant and bottled water (south Catalonia, Spain)
    Martínez, Joana
    Picardo, Massimo
    Peñalver, Alejandra
    Fabregas, Josepa
    Aguilar, Carme
    Borrull, Francesc
    Environmental Science and Pollution Research, 2024, 31 (45) : 56536 - 56549
  • [10] Fate of cyanobacteria in drinking water treatment plant lagoon supernatant and sludge
    Pestana, Carlos J.
    Reeve, Petra J.
    Sawade, Emma
    Voldoire, Camille F.
    Newton, Kelly
    Praptiwi, Radisti
    Collingnon, Lea
    Dreyfus, Jennifer
    Hobson, Peter
    Gaget, Virginie
    Newcombe, Gayle
    SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 565 : 1192 - 1200