Experimental kinematic calibration of parallel manipulators using a relative position error measurement system

被引:62
|
作者
Abtahi, Mansour [1 ]
Pendar, Hodjat [1 ]
Alasty, Aria [1 ]
Vossoughi, Gholamreza [1 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, CEDRA, Tehran 1458889694, Iran
关键词
Calibration; Parallel robots; Hexaglide manipulator; Geometric parameters; Optimization; AUTONOMOUS CALIBRATION; SELF-CALIBRATION; MECHANISMS;
D O I
10.1016/j.rcim.2010.05.007
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Because of errors in the geometric parameters of parallel robots, it is necessary to calibrate them to improve the positioning accuracy for accurate task performance. Traditionally, to perform system calibration, one needs to measure a number of robot poses using an external measuring device. However, this process is often time-consuming, expensive and difficult for robot on-line calibration. In this paper, a methodical way of calibration of parallel robots is introduced. This method is performable only by measuring joint variable vector and positioning differences relative to a constant position in some sets of configurations that the desired positions in each set are fixed, but the moving platform orientations are different. In this method, measurements are relative, so it can be performed by using a simple measurement device. Simulations and experimental studies on a Hexaglide parallel robot built in the Sharif University of Technology reveal the convenience and effectiveness of the proposed robot calibration method for parallel robots. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:799 / 804
页数:6
相关论文
共 50 条
  • [1] Experimental results on kinematic calibration of parallel manipulators using a partial pose measurement device
    Rauf, A
    Pervez, A
    Ryu, J
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2006, 22 (02) : 379 - 384
  • [2] Study of error modeling in kinematic calibration of parallel manipulators
    Wang, Liping
    Liu, Yuzhe
    Wu, Jun
    Wang, Jinsong
    Zhang, Binbin
    [J]. INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2016, 13 : 1 - 12
  • [3] KINEMATIC CALIBRATION OF THE HEXAGLIDE PARALLEL ROBOT USING A SIMPLE MEASUREMENT SYSTEM
    Abtahi, Mansour
    Pendar, Hodjat
    Alasty, Aria
    Vossoughi, Gholamreza
    [J]. IMECE 2008: MECHANICAL SYSTEMS AND CONTROL, VOL 11, 2009, : 853 - 859
  • [4] ESTIMATION MODEL FOR KINEMATIC CALIBRATION OF MANIPULATORS WITH A PARALLEL STRUCTURE
    KUGIUMTZIS, D
    LILLEKJENDLIE, B
    [J]. JOURNAL OF ROBOTIC SYSTEMS, 1994, 11 (05): : 399 - 410
  • [5] Parameter identification algorithm of kinematic calibration in parallel manipulators
    Liu, Yuzhe
    Wu, Jun
    Wang, Liping
    Wang, Jinsong
    [J]. ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (09): : 1 - 16
  • [6] Complete, minimal and continuous error models for the kinematic calibration of parallel manipulators based on POE formula
    Chen, Genliang
    Kong, Lingyu
    Li, Qinchuan
    Wang, Hao
    Lin, Zhongqin
    [J]. MECHANISM AND MACHINE THEORY, 2018, 121 : 844 - 856
  • [7] Analysis of the influence of passive joints on kinematic calibration of parallel manipulators based on complete error model
    Yuan, Xin
    Kong, Lingyu
    Zhang, Zhuang
    Huang, Guanyu
    Xie, Anhuan
    Chen, Genliang
    [J]. PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2024, 90 : 56 - 70
  • [8] Force free add-on position measurement device for the TCP of parallel kinematic manipulators
    Verl, A.
    Croon, N.
    Kramer, C.
    Garber, T.
    [J]. CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2006, 55 (01) : 407 - 410
  • [9] Kinematic calibration and pose measurement of a medical parallel manipulator by optical position sensors
    Bai, SP
    Teo, MY
    [J]. JOURNAL OF ROBOTIC SYSTEMS, 2003, 20 (04): : 201 - 209
  • [10] Error Modeling and Kinematic Calibration of Parallel Robots
    Yu, Dayong
    Cong, Dacheng
    [J]. 2008 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-11, 2008, : 2162 - 2167