Dynamic PET Image Reconstruction Using a Spatial-Temporal Edge-Preserving Prior

被引:0
|
作者
Bian, Zhaoying [1 ]
Ma, Jianhua [1 ]
Lu, Lijun [1 ]
Huang, Jing [1 ]
Zhang, Hua [1 ]
Chen, Wufan [1 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dynamic positron emission tomography (PET) imaging provides important quantitative information of physiological and biochemical processes in humans and animals. However, due to short-time acquisitions to obtain a time sequence of images for parametric imaging, the signal-to-noise ratio of measurement data in each time frame is often very low, which leads the dynamic PET image reconstruction to be a challenging task. And some noticeable errors are inevitable transferred to the voxel-wise kinetic parameter imaging from the associative noisy TAC measurements. To tackle this problem, maximum a posteriori (MAP) statistical reconstruction methods are widely used by incorporating some prior information. Conventional priors focus on local neighborhoods in individual image frames and subsequently penalize inter-voxel intensity differences through different penalty functions such as the quadratic membrane smoothing prior and non-quadratic edge-preserving prior, failing to explore the temporal information of dynamic PET data. In this paper, we design a spatial-temporal edge-preserving (STEP) prior model under the framework of bilateral filter by considering both the spatial local neighborhoods and the temporal kinetic information. Experimental results via a computer simulation study demonstrate that the present dynamic PET reconstruction method with the STEP prior can achieve noticeable gains than the conventional Huber prior in term of signal-to-noise and bias-variance evaluations for the parametric images.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Iterative Image Reconstruction for CBCT Using Edge-Preserving Prior
    Wang, J.
    Li, T.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Iterative image reconstruction for CBCT using edge-preserving prior
    Wang, Jing
    Li, Tianfang
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2009, 36 (01) : 252 - 260
  • [3] Edge-Preserving PET Image Reconstruction Using Trust Optimization Transfer
    Wang, Guobao
    Qi, Jinyi
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (04) : 930 - 939
  • [4] An Edge-Preserving Image Reconstruction Using Neural Network
    Paul Bao
    Dianhui Wang
    [J]. Journal of Mathematical Imaging and Vision, 2001, 14 : 117 - 130
  • [5] An edge-preserving image reconstruction using neural network
    Bao, P
    Wang, DH
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2001, 14 (02) : 117 - 130
  • [6] MRI reconstruction with an edge-preserving filtering prior
    Zhuang, Peixian
    Zhu, Xiaowen
    Ding, Xinghao
    [J]. SIGNAL PROCESSING, 2019, 155 : 346 - 357
  • [7] Low-Dose CBCT by Iterative Image Reconstruction Using NonLocal Edge-Preserving Prior
    Wang, J.
    Ouyang, L.
    Lu, W.
    Solberg, T.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [8] Redundancy Information Induced Edge-Preserving Prior for Perfusion CT Image Reconstruction
    Zhang, Hua
    Ma, Jianhua
    Liang, Zhengrong
    Huang, Jing
    Fan, Yi
    Lu, Hongbing
    Chen, W.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2597 - 2601
  • [9] Penalized Likelihood PET Image Reconstruction Using Patch-Based Edge-Preserving Regularization
    Wang, Guobao
    Qi, Jinyi
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (12) : 2194 - 2204
  • [10] Bayesian restoration using a new nonstationary edge-preserving image prior
    Chantas, Giannis K.
    Galatsanos, Nikolaos P.
    Likas, Aristidis C.
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (10) : 2987 - 2997