Physiological differences between interstitial glucose and blood glucose measured in human subjects

被引:146
|
作者
Kulcu, E
Tamada, JA
Reach, G
Potts, RO
Lesho, MJ
机构
[1] Cygnus, Redwood City, CA 94063 USA
[2] Hop Hotel Dieu, INSERM, U341, Dept Diabet, Paris, France
关键词
D O I
10.2337/diacare.26.8.2405
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - This study investigated whether glucose readings from a sensor sampling in interstitial fluid differ substantially from blood glucose (BG) values measured at the same time. RESEARCH DESIGN AND METHODS - We have evaluated the relationship between BG and glucose extracted from interstitial fluid using the GlucoWatch (Cygnus, Redwood City, CA) biographer, a device that collects glucose from subcutaneous interstitial space through intact skin by application of a low electric current. We evaluated the relative change in the interstitial glucose (IG) signal (IGS) as measured by the biographer versus BG using a normalized two-point sensitivity index (NSI). RESULTS - The results show that biographer measures of IG differ in time and magnitude from the corresponding BG values. In particular, the biographer values were shifted in time due to instrumental and physiological lag. Results show an average total lag of 17.2 +/- 7.2 min for all subjects evaluated. The instrumental lag was 13.5 min, suggesting that physiological lag is similar to5 min. In addition, when glucose was increasing, the change in IGS was less than that in BG, while when BG was decreasing, the change in IGS was greater than that in BG. CONCLUSIONS - Similar results have been reported for other measures of IG, suggesting that differences reflect physiological variation in glucose uptake, utilization, and elimination in blood and interstitial space. This further evidence of the difference between IG and BG should be considered when interpreting glucose measurements from devices that sample interstitial fluid.
引用
收藏
页码:2405 / 2409
页数:5
相关论文
共 50 条
  • [1] Physiological differences between interstitial and blood glucose
    Kulcu, E
    Lesho, MJ
    Tamada, JA
    Reach, G
    Potts, RO
    [J]. DIABETES, 2002, 51 : A11 - A11
  • [2] Timing of changes in interstitial and blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    [J]. DIABETES, 2000, 49 : A99 - A99
  • [3] Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    [J]. DIABETES, 2003, 52 (11) : 2790 - 2794
  • [4] Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
    Moyer, James
    Wilson, Donald
    Finkelshtein, Irina
    Wong, Bruce
    Potts, Russell
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (05) : 398 - 402
  • [5] Relationship Between Interstitial and Blood Glucose During Hypoglycemia in Subjects with Type 2 Diabetes
    Choudhary, Pratik
    Lonnen, Kathryn
    Emery, Celia J.
    Freeman, Jenny V.
    McLeod, Ken M.
    Heller, Simon R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (11) : 1121 - 1127
  • [6] Modeling of relationship between glucose concentration in blood and glucose concentration in interstitial fluid
    Shi, Ting
    Li, Dachao
    Ji, Yongjie
    Li, Guoqing
    Xu, Kexin
    [J]. DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES V, 2012, 8215
  • [7] Nonadjunctive Use of Tissue Glucose Monitoring Systems: Differences in Measured Tissue and Blood Glucose Concentrations
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Kamecke, Ulrike
    Westhoff, Antje
    Haug, Cornelia
    [J]. DIABETES, 2017, 66 : A236 - A237
  • [8] Correlation between blood glucose and cerebrospinal fluid glucose levels in patients with differences in glucose metabolism
    Tan, Qing Che
    Xing, Xiao Wei
    Zhang, Jia Tang
    He, Mian Wang
    Ma, Yu Bao
    Wu, Lei
    Wang, Xiaolin
    Wang, Hong Fen
    Yu, Sheng Yuan
    [J]. FRONTIERS IN NEUROLOGY, 2023, 14
  • [9] Differences in glucose readings between the continuous glucose monitoring calibration free interstitial sensors versus capillary blood glucose monitoring by glucometer: An analysis of two cases
    Quah, Phaik Ling
    Chai, Sally Mun Hua
    Tan, Kok Hian
    [J]. METABOLISM OPEN, 2024, 22
  • [10] CONTINUOUS INVIVO DETERMINATION OF BLOOD GLUCOSE IN HUMAN SUBJECTS
    WELLER, C
    LINDER, M
    MACAULAY, A
    FERRARI, A
    KESSLER, G
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1960, 87 (02) : 658 - 668