Optical path correlator for low-coherence multiplexing fiber optic sensor

被引:0
|
作者
Yuan, Yonggui [1 ]
Wu, Bing [1 ]
Yang, Jun [1 ]
Yuan, Libo [1 ]
机构
[1] Harbin Engn Univ, Sch Sci, Photon Res Ctr, Harbin 150001, Peoples R China
关键词
Optical fiber sensor; white light interferometer; fiber loop resonator; optical path correlation; TEMPERATURE SENSOR; SYSTEM;
D O I
10.1117/12.884727
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Based on a cavity length tunable fiber loop resonator, a multi-beam optical path difference is generated. It can be used to match and correlate the reflective signals from the partial reflective ends of each sensing fiber gauge. The correlation signals corresponding to the sensing gauge lengths. And the shift of the correlation peak related with the fiber sensing gauge elongation caused by strain or temperature. Therefore, it can be used to measure distributed strain or deformation for smart structural monitoring.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Two-loop-based low-coherence multiplexing fiber-optic sensor network with a Michelson optical path demodulator
    Yuan, LB
    Yang, J
    [J]. OPTICS LETTERS, 2005, 30 (06) : 601 - 603
  • [2] Two-loop based low-coherence multiplexing fiber optic sensors network with Michelson optical path demodulator
    Yuan, LB
    Yang, J
    [J]. 17th International Conference on Optical Fibre Sensors, Pts 1 and 2, 2005, 5855 : 595 - 598
  • [3] Common-path low-coherence interferometry fiber-optic sensor guided microincision
    Zhang, Kang
    Kang, Jin U.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (09)
  • [4] Optical path automatic compensation low-coherence interferometric fibre-optic temperature sensor
    Yuan, LB
    [J]. OPTICS AND LASER TECHNOLOGY, 1998, 30 (01): : 33 - 38
  • [6] Fiber-optic temperature sensor using low-coherence interferometry
    Jedrzejewska-Szczerska, M.
    Bogdanowicz, R.
    Gnyba, M.
    Hypszer, R.
    Kosmowski, B. B.
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2008, 154 (1): : 107 - 111
  • [7] Fiber-optic temperature sensor using low-coherence interferometry
    M. Jedrzejewska-Szczerska
    R. Bogdanowicz
    M. Gnyba
    R. Hypszer
    B. B. Kosmowski
    [J]. The European Physical Journal Special Topics, 2008, 154 : 107 - 111
  • [8] Multichannel acousto-optic correlator that uses a low-coherence source
    [J]. 1600, Optical Soc of America, Washington, DC, USA (20):
  • [9] Enhancement of multiplexing capability of low-coherence interferometric fiber sensor array by use of a loop topology
    Yuan, LB
    Jin, W
    Zhou, LM
    Hoo, YL
    Demokan, AS
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2003, 21 (05) : 1313 - 1319
  • [10] Low-Coherence Homodyne Interferometer for Sub-Megahertz Fiber Optic Sensor Readout
    Volkov, Petr
    Lukyanov, Andrey
    Goryunov, Alexander
    Semikov, Daniil
    Vyazankin, Oleg
    [J]. SENSORS, 2024, 24 (02)