Over-the-Wire Intravascular Ultrasound in an Animal Model of Pulmonary Hypertension

被引:1
|
作者
Haynes, Susan E. [1 ]
Divekar, Abhay A. [1 ]
机构
[1] Univ Iowa, Childrens Hosp, Dept Pediat, Div Pediat Cardiol, Iowa City, IA 52240 USA
关键词
intravascular ultrasound; pulmonary hypertension; cardiac catheterization; swine; in vivo vascular dynamics; CHRONIC HYPOXIA; ARTERIAL-HYPERTENSION; CHILDREN; VASCULATURE; DISEASE;
D O I
10.3109/08941939.2011.560997
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Intravascular ultrasound (IVUS) measures prognostically important pulsatile flow indexes in patients with pulmonary hypertension (PH). IVUS catheters traditionally require a guiding catheter for placement which can impact hemodynamics in small infants because the guiding catheter renders the atrioventricular valve incompetent. Methods: Domestic swine (1.4-2.2 kg) were raised in isobaric normoxia (n = 4) or hypoxia (n = 3, FiO(2) 10-12%) for 72 hr for induction of PH. Cardiac catheterization and intravascular imaging was performed using a 3.5-Fr 20-MHz Eagle Eye Gold catheter (Volcano Corp., CA, USA) over a 0.014 '' guide wire. Intima-media thickness (IMT) was measured and relative area change and vascular pulsatility were calculated. Results: The IVUS probe was easily manipulated over a 0.014 '' wire without hemodynamic compromise in all animals. The IMT was thicker in the hypoxic group than the normoxic group (0.19 +/- 0.03 mm vs. 0.31 +/- 0.04 mm, p = .067). Hypoxic animals had systolic PH (39.66 +/- 2.51 vs. 21.75 +/- 2.87 mmHg, p = .02). Systemic arterial pressures between the groups were the same (hypoxic 68 +/- 10.44 vs. normoxic 79.75 +/- 14.84 mmHg, p = .26). Vascular pulsatility was similar (hypoxic 24 +/- 2.64 vs. 20.25 +/- 0.57%, p = .18). However, the arterial wall distensibility was significantly different (0.98 +/- 0.2 vs. 2.01 +/- 1.38 %/mmHg, p = .04). Conclusions: Monorail IVUS imaging without a guide catheter overcomes a major limitation for use in infants and small animal experimental models by avoiding hemodynamic compromise. This would be a valuable tool for assessment of PH in the research and clinical setting.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [1] IN-VIVO VASCULAR DYNAMICS IN AN ANIMAL MODEL OF PULMONARY HYPERTENSION: FEASIBILITY OF USING AN OVER-THE-WIRE ULTRASOUND PROBE
    Haynes, S.
    Divekar, A.
    [J]. PEDIATRIC RESEARCH, 2010, 68 (04) : 363 - 363
  • [2] Prospective evaluation of over-the-wire catheter ultrasound probe
    Chak, A
    Isenberg, G
    Kobayashi, K
    Wong, RCK
    Sivak, MV
    [J]. GASTROINTESTINAL ENDOSCOPY, 1999, 49 (04) : AB154 - AB154
  • [3] DEVELOPMENT OF A FLEXIBLE OVER-THE-WIRE ULTRASOUND CORONARY ABLATION CATHETER
    SIEGEL, RJ
    NITA, H
    STEFFEN, W
    FISHBEIN, MC
    PASSAFARO, J
    [J]. CIRCULATION, 1992, 86 (04) : 457 - 457
  • [4] Percutaneous ultrasound-guided over-the-wire catheterization of the portal and hepatic vessels in cattle
    Mohamed, T
    Oikawa, S
    Nakada, K
    Kurosawa, T
    Sawamukai, Y
    Sato, H
    [J]. JOURNAL OF VETERINARY MEDICAL SCIENCE, 2003, 65 (07): : 821 - 824
  • [5] Intravascular ultrasound assessment of pulmonary vascular disease in patients with pulmonary hypertension
    Bressollette, E
    Dupuis, J
    Bonan, R
    Doucet, S
    Cernacek, P
    Tardif, JC
    [J]. CHEST, 2001, 120 (03) : 809 - 815
  • [6] Intravascular ultrasound imaging of the proximal pulmonary arteries in primary pulmonary hypertension
    Nakamoto, T
    Hase, T
    Toyoda, S
    Nakamachi, T
    Kuga, H
    Kishiro, I
    Okamoto, S
    Ohnuma, N
    Harasawa, H
    Kato, K
    Kaneko, N
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A155 - A155
  • [7] Intravascular ultrasound imaging of pulmonary artery with high-altitude pulmonary hypertension
    Pu, Yunfei
    Cui, Yuxuan
    Li, Bin
    Liu, Chunqiu
    Li, Yeqing
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (04) : 3204 - 3209
  • [8] Prospective evaluation of an over-the-wire catheter US probe
    Chak, A
    Isenberg, G
    Kobayashi, K
    Wong, RCK
    Sivak, MV
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (02) : 202 - 205
  • [9] ABNORMAL PULMONARY ARTERY STIFFNESS IN PULMONARY ARTERIAL HYPERTENSION: IN VIVO STUDY WITH INTRAVASCULAR ULTRASOUND
    Lau, E. M. T.
    Iyer, N.
    Ilsar, R.
    Bailey, B. P.
    Adams, M. R.
    Celermajer, D. S.
    [J]. RESPIROLOGY, 2012, 17 : 19 - 19
  • [10] Abnormal Pulmonary Artery Stiffness in Pulmonary Arterial Hypertension: In Vivo Study with Intravascular Ultrasound
    Lau, Edmund M. T.
    Iyer, Nithin
    Ilsar, Rahn
    Bailey, Brian P.
    Adams, Mark R.
    Celermajer, David S.
    [J]. PLOS ONE, 2012, 7 (03):