Screen-printed amalgam electrodes

被引:5
|
作者
Josypcuk, Bohdan [1 ]
Langmaier, Jan [1 ]
Tvorynska, Sofiia [1 ,2 ]
机构
[1] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 2155-3, Prague 18223, Czech Republic
[2] Charles Univ Prague, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Fac Sci, Hlavova 2030-8, Prague 12843, Czech Republic
关键词
Electrochemistry; Screen-printed electrodes; Silver amalgam; Flow analysis; Iodine determination; SILVER SOLID AMALGAM; ELECTROCHEMICAL BIOSENSORS; TUBULAR DETECTOR; VOLTAMMETRIC DETERMINATION; ENZYMATIC REACTOR; METAL-IONS; PROTEIN; DESIGN;
D O I
10.1016/j.snb.2021.130583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silver amalgam screen-printed electrodes (AgA-SPEs) were designed, prepared and tested for the first time as perspective representatives among SPEs that allow measuring at high negative potentials. For this purpose, the precise electrochemical (coulometric) preparation procedure for mercury deposition at the silver working electrode surface of the commercial silver-SPE was developed and a universal method of preparing amalgam electrodes from different metal-SPEs was described. An optimal electrolyzer construction for the mercury deposition, electrolyte composition, electrolysis potential, and a way to activate the electrode surface for its uniform coverage by mercury were proposed. The effect of the mercury content in amalgam on the potential of hydrogen evolution (PHE) at AgA-SPEs was investigated. The maximum PHE value (-1979 +/- 4 mV; RSD = 0.17 %; N = 5) was found on AgA-SPE with 50 % (w/w) of Hg content in 0.1 mol L-1 NaOH, which is more negative than in the case of the original silver-SPE for 387 mV (-1592 +/- 12 mV; RSD = 0.69 %; N = 5). Determination of the iodine content in iodinated table salt was used for the AgA-SPEs practical testing. Measurement parameters were optimized for three electrochemical cell arrangements: i) the electrodes area of AgA-SPE was covered by 50 mu L of the sample solution and differential pulse voltammetric (DPV) measurements were carried out; ii) 3-electrode batch arrangement with only working electrode from AgA-SPE connected with an analyzer for DPV-measurements; iii) amperometric measurements in a flow system. The results of iodine analysis by all three methods were consistent with the manufacturer declared values.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Screen-printed electrodes
    Nascimento, VB
    Angnes, L
    QUIMICA NOVA, 1998, 21 (05): : 614 - 629
  • [2] Screen-Printed Carbon Electrodes for the Detection of Boldenone
    Kaur, Rameeta
    Khan, Aamir Amanat Ali
    Dennis, John Ojur
    Abdullah, Mohd Azmuddin
    PROCESS AND ADVANCED MATERIALS ENGINEERING, 2014, 625 : 809 - +
  • [3] Electrochemiluminescence Biosensors Using Screen-Printed Electrodes
    Martinez-Perinan, Emiliano
    Gutierrez-Sanchez, Cristina
    Garcia-Mendiola, Tania
    Lorenzo, Encarnacion
    BIOSENSORS-BASEL, 2020, 10 (09):
  • [4] Screen-Printed Electrodes for Amperometric Determination of Iodide
    Khodari, M.
    Bilitewski, U.
    Basry, A. A. H.
    ELECTROANALYSIS, 2015, 27 (02) : 281 - 284
  • [5] Screen-printed reference electrodes for potentiometric measurements
    Tymecki, L
    Zwierkowska, Z
    Koncki, R
    ANALYTICA CHIMICA ACTA, 2004, 526 (01) : 3 - 11
  • [6] Screen-printed Electrodes for the Determination of Iridium in Drugs
    Zaguirre, Marc
    Arino, Cristina
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    ELECTROANALYSIS, 2018, 30 (12) : 2925 - 2930
  • [7] DISPOSABLE SCREEN-PRINTED ELECTRODES FOR MONITORING HYDRAZINES
    WANG, J
    PAMIDI, PVA
    TALANTA, 1995, 42 (03) : 463 - 467
  • [8] Electrochromic screen-printed tungsten trioxide electrodes
    Velasco, Jon
    Ateka, Ainara
    Larramendi, Idoia Ruiz de
    Campo, Francisco Javier
    ELECTROCHIMICA ACTA, 2024, 493
  • [9] CHEMICALLY MODIFIED, SCREEN-PRINTED CARBON ELECTRODES
    WRING, SA
    HART, JP
    ANALYST, 1992, 117 (08) : 1281 - 1286
  • [10] Recycling Systems Based on Screen-Printed Electrodes
    Inst. Biochem. and Molec. Physiol., University Potsdam, 13122 Berlin, Germany
    不详
    Electroanalysis, 12 (803-807):