Steady particulate flows in a horizontal rotating cylinder

被引:124
|
作者
Yamane, K [1 ]
Nakagawa, M
Altobelli, SA
Tanaka, T
Tsuji, Y
机构
[1] Taisho Pharmaceut Co Ltd, Qual Control Dept, Tokushima 7710194, Japan
[2] Lovelace Inst, Albuquerque, NM 87108 USA
[3] New Mexico Resonance, Albuquerque, NM 87108 USA
[4] Osaka Univ, Fac Engn, Dept Mech Engn, Suita, Osaka 5650871, Japan
关键词
D O I
10.1063/1.869858
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRT) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio similar to 7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity held in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit. (C) 1998 American Institute of Physics.
引用
收藏
页码:1419 / 1427
页数:9
相关论文