Monitoring defects in IC fabrication using a hotelling T2 control chart

被引:19
|
作者
Tong, LI [1 ]
Wang, CH
Huang, CL
机构
[1] Natl Chiao Tung Univ, Dept Ind Engn & Management, Hsinchu, Taiwan
[2] Natl Def Univ, Chung Cheng Inst Technol, Dept Comp Sci, Taoyuan, Taiwan
[3] Adv Semicond Mfg Grp, Proc Engn Dept, Kaohsiung, Taiwan
关键词
C chart; defect; defect clustering; integrated circuits (IC); hotelling T-2 control chart; wafer;
D O I
10.1109/TSM.2004.836659
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Monitoring the wafer defects in integrated circuit (IC) fabrication is essential for enhancing wafer yield. However, significant defect clustering occurs when the wafer is large, so the conventional defect control chart, based on the Poisson distribution, is inappropriate. Defect clustering must also be analyzed to monitor effectively defects in ICI fabrication process control. This study developed a novel procedure using the multivariate Hotelling T-2 control chart, based on the number of defects and the defect clustering index (CI) to monitor simultaneously the number of defects and the defect clusters. The CI does,not require any statistical assumptions concerning the distribution of defects and can accurately evaluate the clustering phenomena. A case study of a Taiwanese IC manufacturer demonstrates the effectiveness of the proposed procedure.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 50 条
  • [1] The Effect of Autocorrelation on the Hotelling T2 Control Chart
    Vanhatalo, Erik
    Kulahci, Murat
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2015, 31 (08) : 1779 - 1796
  • [2] Monitoring autocorrelated compositional data vectors using an enhanced residuals Hotelling T2 control chart
    Zaidi, Fatima Sehar
    Dai, Hong-Liang
    Imran, Muhammad
    Tran, Kim Phuc
    [J]. COMPUTERS & INDUSTRIAL ENGINEERING, 2023, 181
  • [3] The bread production process using application of the Hotelling T2 control chart
    Asri, G. S.
    Citra, F. P.
    Nisa, S. K.
    Lestari, T. E.
    [J]. 4TH ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE, 2019, 2019, 1402
  • [4] Design of Hotelling T2 control chart using various covariance structures
    Nida, Hafiza
    Kashif, Muhammad
    Khan, Muhammad Imran
    Ahmad, Liaquat
    Aslam, Muhammad
    [J]. COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2024, 53 (16) : 5828 - 5839
  • [5] A Robust Bivariate Control Chart Alternative to the Hotelling's T2 Control Chart
    Abu-Shawiesh, Moustafa Omar Ahmed
    Kibria, B. M. Golam
    George, Florence
    [J]. QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2014, 30 (01) : 25 - 35
  • [6] Bivariate copulas on the Hotelling's T2 control chart
    Sukparungsee, Saowanit
    Kuvattana, Sasigarn
    Busababodhin, Piyapatr
    Areepong, Yupaporn
    [J]. COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2018, 47 (02) : 413 - 419
  • [7] Autoregressive coefficients based Hotelling's T2 control chart for structural health monitoring
    Wang, Zengrong
    Ong, K. C. G.
    [J]. COMPUTERS & STRUCTURES, 2008, 86 (19-20) : 1918 - 1935
  • [8] Incorporating principal component analysis into Hotelling T2 control chart for compositional data monitoring
    Imran, Muhammad
    Dai, Hong-Liang
    Zaidi, Fatima Sehar
    Tran, Kim Phuc
    Abbas, Zameer
    Nazir, Hafiz Zafar
    [J]. COMPUTERS & INDUSTRIAL ENGINEERING, 2023, 186
  • [9] ECONOMICALLY DESIGNED HOTELLING'S T2 CONTROL CHART USING VSICL SCHEME
    Torabian, Mohsen
    Moghadam, M. B.
    Faraz, Alireza
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2010, 35 (2D) : 251 - 263
  • [10] Hotelling's T2 control chart with variable sampling intervals
    Aparisi, F
    Haro, CL
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2001, 39 (14) : 3127 - 3140