Efficient Registration of Nonrigid 3-D Bodies

被引:20
|
作者
Chen, Huizhong [1 ]
Kingsbury, Nick [2 ]
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
基金
英国工程与自然科学研究理事会;
关键词
Dual-tree complex wavelet transform (DT-CWT); image registration; optical flow; IMAGE; ALIGNMENT;
D O I
10.1109/TIP.2011.2160958
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a novel method to perform an accurate registration of 3-D nonrigid bodies by using phase-shift properties of the dual-tree complex wavelet transform (DT-CWT). Since the phases of DT-CWT coefficients change approximately linearly with the amount of feature displacement in the spatial domain, motion can be estimated using the phase information from these coefficients. The motion estimation is performed iteratively: first by using coarser level complex coefficients to determine large motion components and then by employing finer level coefficients to refine the motion field. We use a parametric affine model to describe the motion, where the affine parameters are found locally by substituting into an optical flow model and by solving the resulting overdetermined set of equations. From the estimated affine parameters, the motion field between the sensed and the reference data sets can be generated, and the sensed data set then can be shifted and interpolated spatially to align with the reference data set.
引用
收藏
页码:262 / 272
页数:11
相关论文
共 50 条
  • [1] Nonrigid registration of 3-D multichannel microscopy images of cell nuclei
    Yang, Siwei
    Koehler, Daniela
    Teller, Kathrin
    Cremer, Thomas
    Le Baccon, Patricia
    Heard, Edith
    Eils, Roland
    Rohr, Karl
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2008, 17 (04) : 493 - 499
  • [2] Nonrigid 3-D/2-D registration of images using statistical models
    Fleute, M
    Lavallée, S
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 138 - 147
  • [3] Nonrigid registration of 3-D free-hand ultrasound images of the breast
    Xiao, GF
    Brady, JM
    Noble, JA
    Burcher, M
    English, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (04) : 405 - 412
  • [4] Automatic construction of 3-D statistical deformation models of the brain using nonrigid registration
    Rueckert, D
    Frangi, AF
    Schnabel, JA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (08) : 1014 - 1025
  • [5] Analysis of 3-D myocardial motion in tagged MR images using nonrigid image registration
    Chandrashekara, R
    Mohiaddin, RH
    Rueckert, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (10) : 1245 - 1250
  • [6] Nonrigid registration of 3D tensor medical data
    Ruiz-Alzola, J
    Westin, CF
    Warfield, SK
    Alberola, C
    Maier, S
    Kikinis, R
    MEDICAL IMAGE ANALYSIS, 2002, 6 (02) : 143 - 161
  • [7] A "Twisting and Bending" model-based nonrigid image registration technique for 3-D ultrasound carotid images
    Nanayakkara, Nuwan D.
    Chiu, Bernard
    Samani, Abbas
    Spence, J. David
    Samarabandu, Jagath
    Fenster, Aaron
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (10) : 1378 - 1388
  • [8] Nonrigid Point Set Registration-Based 3-D Human Pose Tracking from Depth Data
    Dong-Luong Dinh
    Nguyen Duc Thang
    Lee, Sungyoung
    Kim, Tae-Seong
    5TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING IN VIETNAM, 2015, 46 : 409 - 413
  • [9] Nonrigid Registration of 2-D and 3-D Dynamic Cell Nuclei Images for Improved Classification of Subcellular Particle Motion
    Kim, Il-Han
    Chen, Yi-Chun M.
    Spector, David L.
    Eils, Roland
    Rohr, Karl
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2011, 20 (04) : 1011 - 1022
  • [10] Nonrigid 2-D/3-D registration for patient specific bronchoscopy simulation with statistical shape modeling: Phantom validation
    Deligianni, Fani
    Chung, Adrian J.
    Yang, Guang-Zhong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) : 1462 - 1471