The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography

被引:4
|
作者
Nakamine, Sakari [2 ]
Sakai, Hiroshi [1 ]
Arakaki, Yoshikuni [1 ]
Yonahara, Michiko [1 ]
Kaiya, Tadayoshi [2 ]
机构
[1] Univ Ryukyus, Ophthalmol, 207 Uehara, Nishihara, Okinawa 9030215, Japan
[2] Kaiya Eye Clin, Hamamatsu, Shizuoka 4300903, Japan
关键词
AS-OCT; Fixation lamp; Angle width; Miosis; ULTRASOUND BIOMICROSCOPY; IRIS PARAMETERS; DARK CHANGES; GLAUCOMA; LIGHT; CLOSURE; POPULATION; PREVALENCE;
D O I
10.1007/s10384-017-0533-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 A mu m from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 50 条
  • [1] The effect of internal fixation lamp on anterior chamber angle width measured by anterior segment optical coherence tomography
    Sakari Nakamine
    Hiroshi Sakai
    Yoshikuni Arakaki
    Michiko Yonahara
    Tadayoshi Kaiya
    [J]. Japanese Journal of Ophthalmology, 2018, 62 : 48 - 53
  • [2] Effect of Hemodialysis on Anterior Chamber Angle Measured by Anterior Segment Optical Coherence Tomography
    Shin, Yong Un
    Kim, Ji Hong
    Cho, Heeyoon
    Kim, Dae Sung
    Yi, Joo-Hark
    Han, Sang-Woong
    Seong, Mincheol
    [J]. JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [3] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    L M Sakata
    T T L Wong
    H-T Wong
    R S Kumar
    H M Htoon
    H T Aung
    M He
    T Aung
    [J]. Eye, 2010, 24 : 578 - 587
  • [4] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    Sakata, L. M.
    Wong, T. T. L.
    Wong, H-T
    Kumar, R. S.
    Htoon, H. M.
    Aung, H. T.
    He, M.
    Aung, T.
    [J]. EYE, 2010, 24 (04) : 578 - 587
  • [5] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    [J]. OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [6] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [7] Anatomical Changes of the Anterior Chamber Angle With Anterior-Segment Optical Coherence Tomography
    Liu, Lance
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (12) : 1682 - 1686
  • [8] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [9] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [10] Effect of Body Position on Anterior Chamber Angle Dimensions Assessed by Anterior Segment Optical Coherence Tomography
    Penteado, Rafaella
    Xu, Benjamin
    Yang, Diya
    Proudfoot, James
    Susanna, Remo
    Weinreb, Robert N.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)