Noninvasive assessment of coronary flow reserve with transthoracic signal-enhanced Doppler echocardiography

被引:88
|
作者
Lambertz, H [1 ]
Tries, HP [1 ]
Stein, T [1 ]
Lethen, H [1 ]
机构
[1] Deutsch Klin Diagnost, Dept Cardiol, D-65191 Wiesbaden, Germany
关键词
D O I
10.1016/S0894-7317(99)70134-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The feasibility of noninvasive assessment of coronary flow reserve (CFR) in the distal left anterior descending artery (LAD) with echocardiography-enhanced transthoracic pulsed wave Doppler guided by high-resolution transthoracic color Doppler (TTCD) was investigated. The results were compared with the degree of coronary diameter stenosis obtained during cardiac catheterization. Background: Assessment of CFR has proven to be useful in the selection of patients undergoing invasive treatment of coronary artery disease and in estimating their prognosis. However, CPR could only be determined invasively in everyday practice during catheterization procedures. Recent development of high-resolution TTCD allows transthoracic visualization of distal LAD and supra-apical intramyocardial perforator branches and noninvasive measurement of CPR with pulsed wave Doppler technique. Methods: CFR was determined by measuring the ratio of pulsed wave Doppler time velocity integral during adenosine-induced hyperemia (140 mu g/kg/min intravenously) to baseline value. If the baseline Doppler signal of LAD flow was insufficient, an echocardiography (echo) enhancer (Levovist) was used. Forty-five patients were examined by TTCD (7-MHz B-mode, 5-MHz color Doppler, and 3.5-MHz pulsed wave Doppler) after coronary angiography had been performed. Group 1 consisted of 15 patients without heart disease, group 2 of 15 patients with 50% to 85% isolated LAD diameter stenosis, and group 3 of 15 patients with >85% LAD diameter stenosis. Results: Peripheral LAD coronary how at baseline condition was assessed in 40 (88%) patients with TTCD. CFR could be quantified in 36 (80%) of the 45 patients: in 18 patients without echo enhancer, and in 18 patients with echo-enhancing agent. CPR could not be assessed in 9 (20%) patients. CFR In the various groups was as follows:: group 1, 3.15 +/- 0.57; group 2, 2.23 +/- 0.20 (vs group 1: P < .01); and group 3, 1.64 +/- 0.30 (vs group 2: P < .02). Conclusion: CFR in the LAD can be determined in 80% of patients with pulsed wave Doppler guided by high-resolution TTCD combined with intravenously administer-ed echo-enhancing agent.
引用
收藏
页码:186 / 195
页数:10
相关论文
共 50 条
  • [1] Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment
    Paweł Petkow Dimitrow
    Cardiovascular Ultrasound, 1 (1)
  • [2] Coronary Flow Velocity Reserve Assessment with Transthoracic Doppler Echocardiography
    Simova, Iana
    EUROPEAN CARDIOLOGY REVIEW, 2015, 10 (01) : 12 - 18
  • [3] Assessment of Coronary Flow Velocity Reserve by Noninvasive Transthoracic Doppler Echocardiography in Patients with Angiographically Normal Coronary Arteries
    杨娅
    Thomas BARTEL
    李治安
    Raimund ERBEL
    Current Medical Science, 2005, (05) : 590 - 593
  • [4] Assessment of coronary flow velocity reserve by noninvasive transthoracic doppler echocardiography in patients with angiographically normal coronary arteries
    Yang Ya
    Thomas Bartel
    Li Zhian
    Raimund Erbel
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2005, 25 (5): : 590 - 593
  • [5] Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the right coronary artery by transthoracic Doppler echocardiography: Comparison with intracoronary Doppler guidewire
    Ueno, Y
    Nakamura, Y
    Takashima, H
    Kinoshita, M
    Soma, A
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) : 1074 - 1079
  • [6] Assessment of coronary flow reserve with transthoracic Doppler echocardiography: Comparison with intracoronary Doppler method
    Kim, SM
    Shim, WJ
    Lim, HE
    Hwang, GS
    Song, WH
    Lim, DS
    Kim, YH
    Seo, HS
    Oh, DJ
    Ro, YM
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2000, 15 (02) : 139 - 145
  • [7] Usefulness of coronary flow reserve with transthoracic Doppler echocardiography
    Watanabe, Hiroyuki
    Yokoi, Yoshiaki
    Takeuchi, Kazuhide
    Daimon, Masao
    Takemoto, Kazushi
    Higashiue, Shinichi
    Yoshikawa, Junichi
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [8] Noninvasive assessment of coronary flow reserve by transthoracic Doppler echocardiography in a general referral population: experience on 957 patients
    Lowenstein, J
    Presti, C
    Tiano, C
    EUROPEAN HEART JOURNAL, 2001, 22 : 347 - 347
  • [9] Noninvasive assessment of coronary flow reserve by transthoracic digital color Doppler echocardiography with a high-frequency transducer
    Hozumi, T
    Yoshida, K
    Asami, Y
    Ogata, Y
    Kawamoto, T
    CIRCULATION, 1997, 96 (08) : 4000 - 4000
  • [10] Assessment of coronary flow reserve by adenosine transthoracic echocardiography: Validation with intracoronary Doppler
    Hildick-Smith, DJR
    Maryan, R
    Shapiro, LM
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (09) : 984 - 990