Amperometric electrode for determination of urea using electrodeposited rhodium and immobilized urease

被引:34
|
作者
Velichkova, Yana [1 ]
Ivanov, Yavor [1 ]
Marinov, Ivaylo [1 ]
Ramesh, Rajendran [2 ]
Kamini, Numbi Ramudu [2 ]
Dimcheva, Nina [3 ]
Horozova, Elena [3 ]
Godjevargova, Tzonka [1 ]
机构
[1] Univ Prof A Zlatarov, Dept Biotechnol, Burgas 8010, Bulgaria
[2] Cent Leather Res Inst, Dept Biotechnol, Council Sci & Ind Res, Madras 600020, Tamil Nadu, India
[3] Paisij Hilendarski Univ Plovdiv, Dept Phys Chem, BG-4000 Plovdiv, Bulgaria
关键词
Urea sensing; Urease; Amperometric sensor; Electrodeposition; Rhodium; Polymer membrane; FIELD-EFFECT TRANSISTORS; HEAVY-METALS; BIOSENSOR; AMMONIUM; ION; NITROGEN; SYSTEM;
D O I
10.1016/j.molcatb.2011.01.015
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An amperometric biosensor was developed for determination of urea using electrodeposited rhodium on a polymer membrane and immobilized urease. The urease catalyzes the hydrolysis of urea to NH4+ and HCO3- ions and the liberated ammonia is catalytically and electrochemically oxidized by rhodium present in the rhodinized membrane on the Pt working electrode. Three types of rhodinized polymer membranes were prepared by varying the number of electrodeposition cycles: membrane 1 with 10 deposition cycles, membrane 2 with 40 cycles and membrane 3 with 60 cycles. The morphologies of the rhodinized membranes were investigated by scanning electron microscopy and the results showed that the deposition of rhodium was like flowers with cornices-like centers. The influence of the amount of electrodeposited rhodium over the electrode sensitivity to different concentrations of ammonia was examined initially based on the cyclic voltammetric curves using the three rhodium modified electrodes. The obtained results convincingly show that electrode with rhodinized membrane 1, which contain the lowest amount of electrodeposited rhodium is the most active and sensitive regarding ammonia. It was found that the anodic oxidation peak of ammonia to nitrogen occurs at 0.60V. In order to study the performance of urease amperometric sensor for the determination of urea, experiments at constant potential (0.60V) were performed. The current-time experiments were carried out with urease rhodinized membrane 1 (10 cycles). The amperometric response increased linearly up to 1.75 mM urea. The detection limit was 0.05 mM. The urea biosensor exhibited a high sensitivity of 1.85 mu A mM(-1) cm(-2) with a response time 15s. The Michaelis-Menten constant K-m for the urea biosensor was calculated to be 6.5 mM, indicating that the immobilized enzyme featured a high affinity to urea. The urea sensor showed a good reproducibility and stability. Both components rhodium and urease contribute to the decreasing of the production cost of biosensor by avoiding the use of a second enzyme. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [1] Amperometric enzyme electrode for urea determination using immobilized urease in poly (vinylferrocenium) film
    Kuralay, F
    Özyörük, H
    Yildiz, A
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01): : 500 - 506
  • [2] DETERMINATION OF UREA IN WHOLE-BLOOD USING A UREA ELECTRODE WITH AN IMMOBILIZED UREASE MEMBRANE
    YASUDA, K
    MIYAGI, H
    HAMADA, Y
    TAKATA, Y
    [J]. ANALYST, 1984, 109 (01) : 61 - 64
  • [3] Preparation of a potentiometric immobilized urease electrode and urea determination in serum
    Sehitogullari, A
    Uslan, AH
    [J]. TALANTA, 2002, 57 (06) : 1039 - 1044
  • [4] Potentiometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film
    Kuralay, F
    Özyörük, H
    Yildiz, A
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2005, 109 (02) : 194 - 199
  • [5] Amperometric urea biosensor based on immobilized urease on polypyrrole and macroporous polypyrrole modified Pt electrode
    Hosseinian, Maliheh
    Najafpour, Ghasem
    Rahimpour, Ahmad
    [J]. TURKISH JOURNAL OF CHEMISTRY, 2019, 43 (04) : 1063 - 1074
  • [6] UREA SPECIFIC ENZYME ELECTRODE WITH IMMOBILIZED UREASE
    SHINOZUKA, N
    HAYANO, S
    [J]. NIPPON KAGAKU KAISHI, 1980, (10) : 1651 - 1652
  • [7] Selective determination of urea using urease immobilized on ZnO nanowires
    Ali, Syed M. Usman
    Ibupoto, Zafar Hussain
    Salman, Salah
    Nur, Omer
    Willander, Magnus
    Danielsson, Bengt
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01): : 637 - 643
  • [8] DETERMINATION OF SERUM UREA WITH AN ENZYME THERMISTOR USING IMMOBILIZED UREASE
    DANIELSSON, B
    GADD, K
    MATTIASSON, B
    MOSBACH, K
    [J]. ANALYTICAL LETTERS, 1976, 9 (11) : 987 - 1001
  • [9] Development of Amperometric Biosensor Immobilized by Entrapment of Urease Enzyme in Polypiroll Film for the Determination of Blood Urea
    Busono, Pratondo
    [J]. PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS, 2015, : 123 - 126
  • [10] Fabrication of an amperometric urea biosensor using urease and metal catalysts immobilized by a polyion complex
    Hao, Wu
    Das, Gautam
    Yoon, Hyon Hee
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 747 : 143 - 148