CW DFB-QCL and EC-QCL based sensor for simultaneous NO and NO2 measurements via frequency modulation multiplexing using

被引:1
|
作者
Yu, Yajun [1 ,3 ]
Sanchez, Nancy P. [2 ]
Lou, Minhan [1 ]
Zheng, Chuantao [1 ]
Wu, Hongpeng [1 ]
Gluszek, Aleksander K. [1 ]
Hudzikowski, Arkadiusz J. [1 ]
Griffin, Robert J. [2 ]
Tittel, Frank K. [1 ]
机构
[1] Rice Univ, Dept Elect & Comp Engn, 6100 Main St, Houston, TX 77005 USA
[2] Rice Univ, Dept Civil & Environm Engn, 6100 Main St, Houston, TX 77005 USA
[3] Wuhan Univ, Sch Elect Informat, Wuhan 430072, Hubei, Peoples R China
关键词
quantum cascade laser; nitric oxide; nitrogen dioxide; multi-pass absorption; wavelength modulation spectroscopy; frequency modulation multiplexing; trace gas detection; laser sensors; LASER;
D O I
10.1117/12.2251228
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nitrogen oxides (NOx), including nitric oxide (NO) and nitrogen dioxide (NO2) play important roles in determining the photochemistry of the ambient atmosphere, controlling the production of tropospheric ozone, affecting the concentration levels of the hydroxyl radical, and forming acid precipitation. A sensor system capable of simultaneous measurements of NO and NO2 by using a commercial 76 m astigmatic multi-pass gas cell (MPGC) was developed in order to enable fastresponse NOx detection. A continuous wave (CW), distributed-feedback (DFB) quantum cascade laser (QCL) and a CW external-cavity (EC) QCL were employed for targeting a NO absorption doublet at 1900.075 cm(-1) and a NO2 absorption line at 1630.33 cm(-1), respectively. Both laser beams were combined and transmitted through the MPGC in an identical optical path and subsequently detected by a single mid-infrared detector. A frequency modulation multiplexing scheme was implemented by modulating the DFB-QCL and EC-QCL at different frequencies and demodulating the detector signal with two Labview software based lock-in amplifiers to extract the corresponding second-harmonic (2f) components. Continuous monitoring of NO and NO2 concentration levels was achieved by locking the laser frequencies to the selected absorption lines utilizing a reference cell filled with high concentrations of NO and NO2. The experimental results indicate minor performance degradation associated with frequency modulation multiplexing and no cross talk between the two multiplexed detection channels. The performance of the reported sensor system was evaluated for real time, sensitive and precise detection of NO and NO2 simultaneously.
引用
收藏
页数:6
相关论文
共 19 条
  • [1] Sensitive Detection of Carbon Monoxide using a Compact High Power CW DFB-QCL based QEPAS Sensor
    Stefanski, P.
    Lewicki, R.
    Tarka, J.
    Ma, Y.
    Jahjah, M.
    Tittel, F. K.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [2] Quartz-enhanced photoacoustic spectroscopy-based sensor system for sulfur dioxide detection using a CW DFB-QCL
    Waclawek, J. P.
    Lewicki, R.
    Moser, H.
    Brandstetter, M.
    Tittel, F. K.
    Lendl, B.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 117 (01): : 113 - 120
  • [3] Quartz-enhanced photoacoustic spectroscopy-based sensor system for sulfur dioxide detection using a CW DFB-QCL
    J. P. Waclawek
    R. Lewicki
    H. Moser
    M. Brandstetter
    F. K. Tittel
    B. Lendl
    Applied Physics B, 2014, 117 : 113 - 120
  • [4] Detection of hydrogen peroxide based on long-path absorption spectroscopy using a CW EC-QCL
    Sanchez, N. P.
    Yu, Y.
    Dong, L.
    Griffin, R.
    Tittel, F. K.
    QUANTUM SENSING AND NANO ELECTRONICS AND PHOTONICS XIII, 2016, 9755
  • [5] Sensitive Detection of CO and N2O using a High Power CW 4.61 μm DFB-QCL Based QEPAS Sensor
    Ma, Yufei
    Lewicki, Rafal
    Razeghi, Manijeh
    Yu, Xin
    Tittel, Frank K.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [6] Multi-pass absorption spectroscopy for H2O2 detection using a CW DFB-QCL
    Cao, Yingchun
    Sanchez, Nancy P.
    Jiang, Wenzhe
    Ren, Wei
    Lewicki, Rafal
    Jiang, Dongfang
    Griffin, Robert J.
    Tittel, Frank K.
    ADVANCED OPTICAL TECHNOLOGIES, 2014, 3 (5-6) : 549 - 558
  • [7] Sensitive detection of NO using a compact portable CW DFB-QCL-based WMS sensor
    Cui, Haibin
    Wang, Fei
    Huang, Qunxing
    Yan, Jianhua
    Cen, Kefa
    APPLIED OPTICS, 2020, 59 (30) : 9491 - 9498
  • [8] QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL
    Ma, Yufei
    Lewicki, Rafal
    Razeghi, Manijeh
    Tittel, Frank K.
    OPTICS EXPRESS, 2013, 21 (01): : 1008 - 1019
  • [9] Towards the Realization of a MEMS-based Photoacoustic Chemical Sensor Using Ultracompact EC-QCL (SpriteIR)
    Holthoff, Ellen L.
    Marcus, Logan S.
    Pellegrino, Paul M.
    2013 IEEE SENSORS, 2013, : 1518 - 1521
  • [10] CW EC-QCL Based Sensor for Simultaneous HOD/H2O, N2O and CH4 Detection by Multi-pass Absorption Spectroscopy
    Yu, Yajun
    Sanchez, Nancy P.
    Griffin, Robert J.
    Tittel, Frank K.
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,