A dip-and-read optical aptasensor for detection of tau protein

被引:35
|
作者
Ziu, Iva [1 ]
Laryea, Erving T. [1 ]
Alashkar, Fayza [1 ]
Wu, Colin G. [1 ]
Martic, Sanela [2 ]
机构
[1] Oakland Univ, Dept Chem, Rochester, MI 48309 USA
[2] Trent Univ, Dept Forens Sci Environm & Life Sci, Peterborough, ON K9L 0G2, Canada
关键词
Aptamer; Biolayer interferometry; Optical spectroscopy; Neurodegeneration; Tau protein; SURFACE-PLASMON RESONANCE; HIGHLY SENSITIVE DETECTION; BIOLAYER INTERFEROMETRY; IN-VITRO; CAPILLARY-ELECTROPHORESIS; HUMAN SERUM; ASSAY; ANTIBODIES; PHOSPHORYLATION; PROPAGATION;
D O I
10.1007/s00216-019-02350-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Neurodegeneration currently remains without a differential diagnosis or cure. Tau protein is one of the biomarkers of neurodegenerative diseases commonly known as tauopathies. Tau protein plays an integral role in stabilizing microtubules and cell structure; however, due to post-translational modifications, tau protein undergoes self-assembly into cytotoxic structures and is co-localized intra- and extracellularly. Hence, tau protein is a viable biomarker associated with protein pathogenesis and neurodegeneration. The novel optical biosensor for tau441 protein is based on the aptamer recognition probe and the biolayer interferometry (BLI) method for detection. The current biotin-aptasensor in combination with the streptavidin surface provides real-time monitoring of tau441 protein in the nanomolar range, with the limit of detection at 6.7 nM in vitro. The tau441 detection is achieved with high selectivity over other neurodegeneration biomarkers which include amyloid-beta and alpha-synuclein. The aptasensor also allows for tau441 protein detection in a complex matrix such as fetal bovine serum, indicating its utility in other biological fluids for diagnostic applications. The optical method is simple, rapid and highly selective for point-of-care application which is critical for achieving the early and differential diagnosis of neurodegenerative diseases and identifying their treatments. Graphical abstract
引用
收藏
页码:1193 / 1201
页数:9
相关论文
共 50 条
  • [1] A dip-and-read optical aptasensor for detection of tau protein
    Iva Ziu
    Erving T. Laryea
    Fayza Alashkar
    Colin G. Wu
    Sanela Martic
    Analytical and Bioanalytical Chemistry, 2020, 412 : 1193 - 1201
  • [2] A NEW DIP-AND-READ TEST FOR LEUKOCYTES IN URINE
    SKJOLD, AC
    STOVER, L
    PENDERGRASS, J
    COREY, P
    CATTELL, J
    BURKHARDT, A
    FARINELLI, M
    TYHACH, R
    ALBARELLA, J
    WARD, F
    YIP, T
    HUGL, H
    CLINICAL CHEMISTRY, 1985, 31 (06) : 993 - 993
  • [3] NEW DIP-AND-READ TEST FOR DETERMINING LEUKOCYTES IN URINE
    SKJOLD, AC
    STOVER, LR
    PENDERGRASS, JH
    COREY, PF
    CATTELL, JA
    BURKHARDT, AE
    FARINELLI, MP
    TYHACH, RJ
    ALBARELLA, JP
    TRIMMER, RW
    WARD, FE
    YIP, MT
    HUGL, H
    CLINICAL CHEMISTRY, 1987, 33 (07) : 1242 - 1245
  • [5] INDOXYL SULFATE INTERFERES WITH DIP-AND-READ URINARY BILIRUBIN ESTIMATE
    SKJOLD, AC
    FREITAG, JF
    STOVER, LR
    BERRY, HK
    CLINICAL CHEMISTRY, 1980, 26 (09) : 1368 - 1369
  • [6] The value of dip-and-read urinalysis strips for identifying urinary infection.
    Renfrew, GR
    CLINICAL CHEMISTRY, 2003, 49 (06) : A56 - A57
  • [7] Dip-and-read test strips for the determination of trinitrotoluene (TNT) in drinking water
    Heiss, C
    Weller, MG
    Niessner, R
    ANALYTICA CHIMICA ACTA, 1999, 396 (2-3) : 309 - 316
  • [8] "Dip-and-read" paper-based analytical devices using distance-based detection with color screening
    Yamada, Kentaro
    Citterio, Daniel
    Henry, Charles S.
    LAB ON A CHIP, 2018, 18 (10) : 1485 - 1493
  • [9] URINE PH AND SPECIFIC-GRAVITY MONITORING WITH COLORIMETRIC DIP-AND-READ TESTS
    FREE, AH
    CLINICAL CHEMISTRY, 1982, 28 (07) : 1570 - 1571
  • [10] A dip-and-read test strip for the determination of nitrite in food samples for the field screening
    Fang, YJ
    Gao, ZX
    Yan, SL
    Wang, HY
    Zhou, HY
    ANALYTICAL LETTERS, 2005, 38 (11) : 1803 - 1811