Impact of Inadequate Bowel Cleansing on Colonoscopic Findings in Routine Screening Practice

被引:1
|
作者
Niedermaier, Tobias [1 ]
Amitay, Efrat L. [1 ]
Gies, Anton [2 ,3 ]
Weigl, Korbinian [1 ,4 ]
Hoffmeister, Michael [1 ]
Brenner, Hermann [1 ,2 ,3 ,4 ]
机构
[1] German Canc Res Ctr, Div Clin Epidemiol & Aging Res, Heidelberg, Germany
[2] German Canc Res Ctr, Div Prevent Oncol, Heidelberg, Germany
[3] Natl Ctr Tumor Dis NCT, Heidelberg, Germany
[4] German Canc Res Ctr, German Canc Consortium DKTK, Heidelberg, Germany
关键词
FECAL IMMUNOCHEMICAL TESTS; COLORECTAL-CANCER; MISS RATE; DIAGNOSTIC PERFORMANCE; PREPARATION QUALITY; RISK-FACTORS; BLOOD-TEST; ADENOMA; TEMPERATURE; PREVALENCE;
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
INTRODUCTION: Colonoscopy is an imperfect gold standard for detecting colorectal neoplasms because some proportion of adenomas may be missed, mainly small lesions. This proportion is expected to be higher in case of inadequate bowel cleansing, which is frequently seen in routine practice. We estimated the proportions of neoplasms that are in principle detectable by colonoscopy but might be missed in case of incomplete bowel preparation. METHODS: For 8,193 participants of screening colonoscopy in South-Western Germany, recruited between 2005 and 2016, the prevalence and numbers of different findings were extracted from colonoscopy reports and compared according to the reported bowel preparation quality. RESULTS: Bowel preparation quality was reported as good, poor, or was unspecified in 30.3%, 11.1%, and 58.6% of colonoscopy records. Reported prevalences of nonadvanced adenomas (NAAs) were similar among participants with poor and unspecified bowel preparation quality but substantially lower than among participants with good bowel preparation (adjusted prevalence rate ratio [RR] 0.86, 95% confidence interval [CI]: 0.77-0.96). The differences were observed for proximal but not for distal NAAs (RRs 0.82, 95% CI: 0.71-0.95 and 0.95, 95% CI: 0.82-1.10). DISCUSSION: Our study suggests that a significant proportion of NAAs located in the proximal colon might be missed during colonoscopy if bowel cleansing is not adequate. Major efforts should be made to further facilitate and enhance high-quality bowel preparation in routine screening practice.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Impact of inadequate bowel cleansing in sigmoidoscopy screening
    Randel, Kristin Ranheim
    Schult, Anna Lisa
    Botteri, Edoardo
    Nawaz, Mobina
    Nguyen, Dung Hong
    Holme, Oyvind
    Bretthauer, Michael
    Hoff, Geir
    de Lange, Thomas
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2024, 59 (08) : 1002 - 1009
  • [2] A randomized trial comparing colonoscopic enema with additional oral preparation as a salvage for inadequate bowel cleansing before colonoscopy
    Yang, Hyo-Joon
    Park, Dong Il
    Park, Soo-Kyung
    Kim, Sunyong
    Lee, Taeheon
    Jung, Yunho
    Eun, Chang Soo
    Han, Dong Soo
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 : 258 - 259
  • [3] A Randomized Controlled Trial Comparing Colonoscopic Enema With Additional Oral Preparation as a Salvage for Inadequate Bowel Cleansing Before Colonoscopy
    Yang, Hyo-Joon
    Park, Dong Il
    Park, Soo-Kyung
    Kim, Sunyong
    Lee, Taeheon
    Jung, Yunho
    Fun, Chang Soo
    Han, Dong Soo
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2019, 53 (08) : E308 - E315
  • [4] Eight Years of Colonoscopic Bowel Cancer Screening in Germany Initial Findings and Projections
    Brenner, Hermann
    Altenhofen, Lutz
    Hoffmeister, Michael
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2010, 107 (43): : 753 - 759
  • [5] THE BOWEL CLEANSING NATIONAL INITIATIVE (BCLEAN): PREDICTORS OF INADEQUATE BOWEL PREPARATION
    Barkun, Alan N.
    Martel, Myriam
    Epstein, Ian L.
    Halle, Pierre
    Hilsden, Robert
    James, Paul D.
    Rostom, Alaa
    Sey, Michael
    Singh, Harminder
    Sultanian, Richard
    Telford, Jennifer J.
    von Renteln, Daniel
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB474 - AB474
  • [6] Predictive factors for inadequate bowel cleansing in colon capsule endoscopy
    Gimeno-Garcia, Antonio Z.
    Gonzalez-Suarez, Begona
    Adrian de Ganzo, Zaida
    Alarcon Fernandez, Onofre
    Ramos, Laura
    Giordano, Antonio
    Carretero, Cristina
    Jimenez, Alejandro
    Nicolas, David
    Hernandez Guerra, Manuel
    Quintero, Enrique
    GASTROENTEROLOGIA Y HEPATOLOGIA, 2022, 45 (08): : 605 - 613
  • [7] The impact on clinical practice of routine screening for macroprolactin
    Gibney, J
    Smith, TP
    McKenna, TJ
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (07): : 3927 - 3932
  • [8] FRACTIONAL CLEANSING OF THE LARGE-BOWEL WITH GOLYTELY FOR COLONOSCOPIC PREPARATION - A CONTROLLED TRIAL
    ROSCH, T
    CLASSEN, M
    ENDOSCOPY, 1987, 19 (05) : 198 - 200
  • [9] A SECOND STRATEGY COLON CLEANSING FOR COLONOSCOPY AFTER AN INADEQUATE BOWEL PREPARATION
    Dal Pont, E.
    Cavallaro, L. G.
    Galliani, E.
    Lecis, P.
    Losso, E.
    Germana, B.
    DIGESTIVE AND LIVER DISEASE, 2019, 51 : E150 - E150
  • [10] LARGE BOWEL POLYPS IN SOUTHWESTERN SKANE - COLONOSCOPIC FINDINGS
    CRONSTEDT, J
    WILLEN, R
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1984, 19 : 23 - 23