Assessment of Accelerometers for Measuring Upper-Extremity Physical Activity

被引:0
|
作者
Lawinger, Elizabeth [1 ]
Uhl, Tim L. [1 ]
Abel, Mark [2 ]
Kamineni, Srinath [3 ]
机构
[1] Univ Kentucky, Div Athlet Training, Lexington, KY 40506 USA
[2] Univ Kentucky, Dept Kinesiol & Hlth Promot, Lexington, KY USA
[3] Univ Kentucky, Coll Med, Lexington, KY USA
关键词
rehabilitation; patient compliance; exercise compliance; ROTATOR CUFF REPAIR; WRIST-WORN ACCELEROMETER; TOTAL SHOULDER ARTHROPLASTY; REHABILITATION; ADULTS; HIP; ARM; REPLACEMENT; RELIABILITY; STEPS/DAY;
D O I
10.1123/jsr.2013-0140
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: The overarching goal of this study was to examine the use of triaxial accelerometers in measuring upper-extremity motions to monitor upper-extremity-exercise compliance. There were multiple questions investigated, but the primary objective was to investigate the correlation between visually observed arm motions and triaxial accelerometer activity counts to establish fundamental activity counts for the upper extremity. Study Design: Cross-sectional, basic research. Setting: Clinical laboratory. Participants: Thirty healthy individuals age 26 +/- 6 y, body mass 24 +/- 3 kg, and height 1.68 +/- 0.09 m volunteered. Intervention: Participants performed 3 series of tasks: activities of daily living (ADLs), rehabilitation exercises, and passive shoulder range of motion at 5 specific velocities on an isokinetic dynamometer while wearing an accelerometer on each wrist. Participants performed exercises with their dominant arm to examine differences between sides. A researcher visually counted all arm motions to correlate counts with physical activity counts provided by the accelerometer. Main Outcome Measure: Physical activity counts derived from the accelerometer and visually observed activity counts recorded from a single investigator. Results: There was a strong positive correlation (r = .93, P < .01) between accelerometer physical activity counts and visual activity counts for all ADLs. Accelerometers activity counts demonstrated side-to-side difference for all ADLs (P < .001) and 5 of the 7 rehabilitation activities (P < .003). All velocities tested on the isokinetic dynamometer were shown to be significantly different from each other (P < .001). Conclusion: There is a linear relationship between arm motions counted visually and the physical activity counts generated by an accelerometer, indicating that arm motions could be potentially accounted for if monitoring arm usage. The accelerometers can detect differences in relatively slow arm-movement velocities, which is critical if attempting to evaluate exercise compliance during early phases of shoulder rehabilitation. These results provide fundamental information that indicates that triaxial accelerometers have the potential to objectively monitor and measure arm activities during rehabilitation and ADLs.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 50 条
  • [1] Measuring Outcome in Upper-Extremity Transplantation
    McCabe S.
    McClelland B.
    [J]. Current Transplantation Reports, 2014, 1 (3) : 211 - 214
  • [2] Measuring Upper-Extremity Use with One IMU
    Wang, Hang
    Refai, Mohamed Irfan Mohamed
    van Beijnum, Bert-Jan F.
    [J]. BIOSIGNALS: PROCEEDINGS OF THE 12TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 4: BIOSIGNALS, 2019, : 93 - 100
  • [3] Accelerometry as an objective measure of upper-extremity activity
    Samuel Larrivée
    Emma Avery
    Jeff Leiter
    Jason Old
    [J]. Medical & Biological Engineering & Computing, 2021, 59 : 187 - 194
  • [4] Accelerometry as an objective measure of upper-extremity activity
    Larrivee, Samuel
    Avery, Emma
    Leiter, Jeff
    Old, Jason
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (01) : 187 - 194
  • [5] Predictors of Upper-Extremity Physical Function in Older Adults
    Hermanussen, Hugo H.
    Menendez, Mariano E.
    Chen, Neal C.
    Ring, David
    Vranceanu, Ana-Maria
    [J]. ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2016, 4 (04): : 359 - 365
  • [6] Upper-extremity thrombosis
    Jawad, ASM
    [J]. JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 2004, 97 (03) : 156 - 157
  • [7] A framework for the definition of standardized protocols for measuring upper-extremity kinematics
    Kontaxis, A.
    Cutti, A. G.
    Johnson, G. R.
    Veeger, H. E. J.
    [J]. CLINICAL BIOMECHANICS, 2009, 24 (03) : 246 - 253
  • [8] Physical activity assessment with accelerometers
    KR Westerterp
    [J]. International Journal of Obesity, 1999, 23 : S45 - S49
  • [9] Physical activity assessment with accelerometers
    Westerterp, KR
    [J]. INTERNATIONAL JOURNAL OF OBESITY, 1999, 23 (Suppl 3) : S45 - S49
  • [10] Upper-Extremity Physical-Performance Tests in College Athletes
    Taylor, Jeffrey B.
    Wright, Alexis A.
    Smoliga, James M.
    Depew, J. Tyler
    Hegedus, Eric J.
    [J]. JOURNAL OF SPORT REHABILITATION, 2016, 25 (02) : 146 - 154