Measurements of indoor gamma radiation dose in At-Taif City, Saudi Arabia using CaSO4:Dy (TLD-900)

被引:5
|
作者
Al-Ghorabie, FHH [1 ]
机构
[1] Umm Al Qura Univ, Dept Phys, Fac Sci Appl, Mecca 21955, Saudi Arabia
关键词
D O I
10.1093/rpd/nch437
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes measurements of indoor gamma radiation dose in At-Taif city, Kingdom of Saudi Arabia. CaSO4:Dy thermoluminescence dosemeters were used for the detection of gamma radiation in 250 houses within the city. The values of indoor gamma radiation dose rate measured ranged between 90 and 221 nGy h(-1) for the time interval from September 2002 to September 2003. The measured dose varied with the type of house and season of the year. The highest average value 192 ± 7 nGy h(-1) was measured inside apartments made of cement and brick (157-221 nGy h(-1)), and the lowest average value 92 ± 6 nGy h(-1) in mud houses (58-117 nGy h(-1)). Intermediate values 154 ± 5 nGy h(-1) (128-177 nGy h(-1)) and 167 ± 9 nGy h(-1) (144-185 nGy h(-1)) were observed in large halls and villas, respectively. The average indoor gamma radiation dose rate received by the population of At-Taif city is 138 nGy h(-1) and its corresponding annual dose is 1211 μ Gy y(-1). The calculated mean effective dose to At-Taif city population, assuming an indoor occupancy factor of 80%, is 970 μ Sv y(-1).
引用
收藏
页码:178 / 184
页数:7
相关论文
共 16 条
  • [1] The effect of heating rate on the dose dependence and thermoluminescence characteristics of CaSO4: Dy (TLD-900)
    Kafadar, V. Emir
    Majeed, Karwan F.
    THERMOCHIMICA ACTA, 2014, 590 : 266 - 269
  • [2] KINETICS AND THERMOLUMINESCENT PARAMETERS OF CASO4 - DY RIBBON, TLD-900, AT LOW-DOSE LEVELS
    FURETTA, C
    GENNAI, P
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1981, 55 (1-2): : 23 - 25
  • [3] Intensity variation study of the radiation field in a mammographic system using thermoluminescent dosimeters TLD-900 (CaSO4:DY)
    Correa, E. L.
    Silva, J. O.
    Vivolo, V.
    Potiens, M. P. A.
    Daros, K. A. C.
    Medeiros, R. B.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 116 - 118
  • [4] AN EXTENSIVE STUDY ON THE DOSIMETRIC PROPERTIES OF CASO4 - DY RIBBON, TLD-900, IN LOW-DOSE REGION
    FURETTA, C
    GENNAI, P
    HEALTH PHYSICS, 1981, 41 (04): : 674 - 677
  • [5] THE USE OF CASO4 - DY (TLD-900) FOR MEASUREMENT OF DIAGNOSTIC-X-RAY EXPOSURES
    NIROOMANDRAD, A
    DEWERD, LA
    MEDICAL PHYSICS, 1982, 9 (04) : 624 - 624
  • [6] GAMMA-RADIATION INDUCED SENSITIZATION IN CASO4 - DY TLD PHOSPHOR
    LAKSHMANAN, AR
    CHANDRA, B
    BHATT, RC
    NUCLEAR INSTRUMENTS & METHODS, 1978, 153 (2-3): : 581 - 588
  • [7] DOSIMETRY OF FAST-NEUTRON BEAMS USING CASO4-DY (TLD-900) PELLETS
    PRADHAN, AS
    RASSOW, J
    MEISSNER, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 236 (02): : 396 - 399
  • [8] ENVIRONMENTAL RADIATION MEASUREMENTS USING TLD-900 AT THE KING-SAUD-UNIVERSITY CAMPUS, RIYADH, SAUDI-ARABIA
    ALMOHAWES, NA
    KADACHI, A
    WAHEED, A
    HEALTH PHYSICS, 1991, 61 (06): : 821 - 824
  • [9] High dose measurements using thermoluminescence of CaSO4:Dy
    Mathur, VK
    Lewandowski, AC
    Guardala, NA
    Price, JL
    RADIATION MEASUREMENTS, 1999, 30 (06) : 735 - 738
  • [10] High dose measurements using thermoluminescence of CaSO4:Dy
    Naval Surface Warfare Center, Carderock Division, 9500 MacArthur Blvd, West Bethesda, MD 20817-5700, United States
    Radiat Meas, 6 (735-738):