Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial

被引:11
|
作者
van Os, S. [1 ]
Cheung, P-Y [1 ,2 ]
Kushniruk, K. [1 ]
O'Reilly, M. [1 ,2 ]
Aziz, K. [1 ,2 ]
Schmolzer, G. M. [1 ,2 ]
机构
[1] Royal Alexandra Hosp, Alberta Hlth Serv, Ctr Study Asphyxia & Resuscitat, Edmonton, AB T5H 3V9, Canada
[2] Univ Alberta, Dept Pediat, Div Neonatol, Edmonton, AB, Canada
关键词
BIRTH-WEIGHT INFANTS; EXHALED CARBON-DIOXIDE; NEONATAL RESUSCITATION; DELIVERY ROOM; ESOPHAGEAL INTUBATION; INTENSIVE-CARE; POSITION; INSERTION; DURATION; SUCCESS;
D O I
10.1038/jp.2015.208
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: International resuscitation guidelines recommend clinical assessment and exhaled CO2 to confirm tube placement immediately after intubation. However, exhaled CO2 devices can display false negative results. In comparison, any respiratory function monitor can be used to measure and display gas flow in and out of an endotracheal tube. However, neither method has been examined in detail. We hypothesized that a flow sensor would improve the assessment of tracheal vs esophageal tube placement in neonates with a higher success rate and a shorter time to tube placement confirmation when compared with the use of a quantitative end-tidal CO2 (ETCO2) detector. STUDY DESIGN: Between December 2013 and September 2014, preterm and term infants requiring endotracheal intubation were eligible for inclusion and randomly allocated to either ETCO2 ('ETCO2 group') or flow sensor ('flow sensor group'). All infants were analyzed according to their group at randomization (that is, analysis was by intention-to-treat). RESULT: During the study period, a total of 110 infants (n=55 for each group) were randomized. Successful endotracheal tube placements were correctly identified in 100% of cases by the flow sensor compared with 72% of cases with the ETCO2 detector within 10 inflations (P < 0.05). The median (interquartile range) number of inflations needed to identify successful tube placement was significantly lower in the flow sensor group with 2 (1 to 3) inflations vs 8 (6 to 10) inflations with the ETCO2 detector (P < 0.001). CONCLUSION: A flow sensor would improve the assessment of successful endotracheal tube placement with a higher success rate and a shorter time compared with an ETCO2 detector.
引用
收藏
页码:370 / 375
页数:6
相关论文
共 50 条
  • [1] Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial
    S van Os
    P-Y Cheung
    K Kushniruk
    M O'Reilly
    K Aziz
    G M Schmölzer
    [J]. Journal of Perinatology, 2016, 36 : 370 - 375
  • [2] Erratum: Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial
    S van Os
    P-Y Cheung
    K Kushniruk
    M O'Reilly
    K Aziz
    G M Schmölzer
    [J]. Journal of Perinatology, 2016, 36 : 796 - 796
  • [3] Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial (vol 36, pg 370, 2016)
    van Os, S.
    Cheung, P. -Y
    Kushniruk, K.
    O'Reilly, M.
    Aziz, K.
    Schmolzer, G. M.
    [J]. JOURNAL OF PERINATOLOGY, 2016, 36 (09) : 796 - 796
  • [4] ENDOTRACHEAL-TUBE PLACEMENT IN INFANTS
    GOLDENRING, JM
    [J]. PEDIATRICS, 1986, 77 (01) : 131 - 132
  • [5] Early Endotracheal Tube Insertion with the GlideScope: A Randomized Controlled Trial
    Turkstra, Timothy P.
    Cusano, Fiorenzo
    Fridfinnson, Jason A.
    Batohi, Pravin
    Rachinsky, Maxim
    [J]. ANESTHESIA AND ANALGESIA, 2016, 122 (03): : 753 - 757
  • [6] ENDOTRACHEAL-TUBE PLACEMENT IN INFANTS - REPLY
    HELLER, RM
    COTTON, RB
    [J]. PEDIATRICS, 1986, 77 (01) : 132 - 132
  • [7] A Randomized Controlled Trial of Capnography in the Correction of Simulated Endotracheal Tube Dislodgement
    Langhan, Melissa L.
    Ching, Kevin
    Northrup, Veronika
    Alletag, Michelle
    Kadia, Payal
    Santucci, Karen
    Chen, Lei
    [J]. ACADEMIC EMERGENCY MEDICINE, 2011, 18 (06) : 590 - 596
  • [8] Comparison of supraglottic airway device and endotracheal tube in former preterm infants receiving general anesthesia: a randomized controlled trial
    Hu, Pin-Yang
    Chang, Yu-Tang
    Yang, Shu-Ting
    Wu, Ching-Shu
    Cheng, Kuang-, I
    Su, Miao-Pei
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [9] RAPID MANEUVERS TO DETERMINE LOCATION OF ENDOTRACHEAL TUBE IN NEWBORN INFANTS
    SCANLON, JW
    [J]. JOURNAL OF PEDIATRICS, 1973, 82 (06): : 1091 - 1092
  • [10] TRANSCUTANEOUS, NONRADIOGRAPHIC DETERMINATION OF ENDOTRACHEAL-TUBE (ET) PLACEMENT - A RANDOMIZED CONTROLLED-STUDY
    TE, M
    MENDOZA, G
    KHALIFEH, M
    DWECK, HS
    [J]. PEDIATRIC RESEARCH, 1990, 27 (04) : A36 - A36