Aortic valve neocuspidization using autologous pericardium compared to surgical aortic valve replacement

被引:4
|
作者
Boehm, Johannes [1 ,2 ]
Vitanova, Keti [1 ,2 ]
Prinzing, Anatol [1 ,2 ]
Krane, Markus [3 ,4 ]
Lange, Ruediger [1 ,2 ,3 ]
机构
[1] Tech Univ Munich, Dept Cardiovasc Surg, German Heart Ctr Munich, Munich, Germany
[2] Tech Univ Munich, Insure Inst Translat Cardiac Surg, Dept Cardiovasc Surg, German Heart Ctr, Munich, Germany
[3] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart, Alliance, OH, Germany
[4] Yale Sch Med, Div Cardiac Surg, New Haven, CT USA
关键词
cardiovascular research; valve repair; replacement; PROSTHESIS-PATIENT MISMATCH; LONG-TERM SURVIVAL; HEMODYNAMIC PERFORMANCE; RECONSTRUCTION; EXPERIENCE; OUTCOMES; DURABILITY; TRIFECTA; IMPACT;
D O I
10.1111/jocs.16800
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Aortic valve neocuspidization (AVNeo) for trileaflet aortic valve reconstruction using autologous pericardium (Ozaki procedure) depicts an encouraging new technique for the surgical treatment of aortic valve pathologies. The current study analyzes the early hemodynamic outcome of AVneo compared with surgical aortic valve replacement (SAVR) using the Abbott/St. Jude Trifecta aortic valve biological prostheses. Methods All patients who underwent either AVNeo or SAVR between March 2017 and April 2020 were included. Exclusion criteria were emergency cases, endocarditis, redo- or additional root procedures. Main endpoints were differences between the two groups in terms of the effective orifice area (EOA) and the effective orifice area index (EOAI) at discharge. Results During the study period, 105 AVNeo patients and 458 SAVR patients met the inclusion criteria. EOA was significantly higher in the AVNeo group (2.4 cm(2) +/- 0.8 vs. 2.1 cm(2)/m(2 )+/- 0.6 in the SAVR group, respectively; p < .001). Multiple regression analysis, including AVNeo, annulus size, bicuspid valve, preoperative stenosis, left ventricular ejection fraction (LVEF), and diastolic diameter (LVEDD) found two factors, which favor larger EOA: Annulus size (p < .0001) and AVneo (p = .005). EOAI was significantly higher in the AVNeo group (1.23 +/- 0.4 vs. 1.02 cm(2)/m(2) +/- 0.3, respectively; p < .001). Multiple regression analysis for EOAI showed effects for AVneo (p = .005) and bicuspid valve (p = .029). Mean pressure gradients (MPG) were lower in the AVNeo group than in the SAVR group (AVNeo: MPG = 8.0 mmHg +/- 3.6 vs. SAVR: MPG = 8.3 mmHg +/- 3.6), but this finding did not reach statistical significance (p = .091). Conclusions AVNeo shows significantly larger EOA and EOAI compared to SAVR using the Abbott/St. Jude Trifecta aortic valve biological prostheses.
引用
下载
收藏
页码:3110 / 3116
页数:7
相关论文
共 50 条
  • [1] Aortic Valve Neocuspidization Using Autologous Pericardium (Ozaki Procedure): an Alternative to Aortic Valve Replacement in Adult Cardiac Surgery?
    Luca Koechlin
    Friedrich S. Eckstein
    Current Anesthesiology Reports, 2021, 11 : 318 - 325
  • [2] Aortic Valve Neocuspidization Using Autologous Pericardium (Ozaki Procedure): an Alternative to Aortic Valve Replacement in Adult Cardiac Surgery?
    Koechlin, Luca
    Eckstein, Friedrich S.
    CURRENT ANESTHESIOLOGY REPORTS, 2021, 11 (03) : 318 - 325
  • [3] Aortic Valve Neocuspidization Using Xenologous Pericardium Versus Bioprosthetic Valve Replacement
    Mitrev, Zan
    Risteski, Petar
    Todorovska, Marija
    Pavlovikj, Monika
    Pompeu, Michel
    Rosalia, Rodney
    ANNALS OF THORACIC SURGERY, 2022, 113 (04): : 1192 - 1199
  • [4] Transcatheter aortic valve implantation after aortic valve neocuspidization using autologous pericardium: a case report
    Tada, Norio
    Tanaka, Naoyuki
    Abe, Kazuo
    Hata, Masaki
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2019, 3 (03)
  • [5] Short-term outcomes of aortic valve neocuspidization using autologous fixed pericardium versus aortic valve replacement using mechanical prosthesis in patients with aortic valve disease
    El Barbary, Moustafa Gamal-Eldin
    Seddik, Amr Ahmed Mohamed
    Hussein, Mohamed Attia
    Omar, Ahmed Helmy
    EGYPTIAN JOURNAL OF SURGERY, 2023, 42 (03): : 774 - 780
  • [6] AORTIC-VALVE REPLACEMENT WITH AUTOLOGOUS PERICARDIUM - SURGICAL TECHNIQUE
    DURAN, CMG
    GALLO, R
    KUMAR, N
    JOURNAL OF CARDIAC SURGERY, 1995, 10 (01) : 1 - 9
  • [7] Excellent Hemodynamic Performance After Aortic Valve Neocuspidization Using Autologous Pericardium
    Krane, Markus
    Boehm, Johannes
    Prinzing, Anatol
    Ziegelmueller, Johannes
    Holfeld, Johannes
    Lange, Ruediger
    ANNALS OF THORACIC SURGERY, 2021, 111 (01): : 126 - 133
  • [8] A Case of Severe Aortic Stenosis after Aortic Valve Neocuspidization Using Autologous Pericardium (Ozaki Procedure)
    Mikami, Takuma
    Uchiyama, Hiroki
    Maeda, Toshiyuki
    Nakashima, Shinji
    Satoshi, Muraki
    Taku, Sakurada
    Araki, Eiji
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 29 (05) : 261 - 265
  • [9] Aortic Valve Neocuspidization Using Glutaraldehyde-Treated Autologous Pericardium: A Literature Review
    Chan, J.
    Basu, A.
    Discenza, G.
    Bartlett, J.
    Fan, K. S.
    Oo, S.
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [10] Aortic valve neocuspidization using autologous versus bovine pericardium: Ozaki versus Batista
    Jubouri, Matti
    Tan, Sven Z. C. P.
    Mohammed, Idhrees
    Bashir, Mohamad
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 5207 - 5209