A new proposal on the operational quantity Hp(3): Monte Carlo and experimental results

被引:4
|
作者
Mariotti, F. [1 ]
Gualdrini, G. [1 ]
Fantuzzi, E. [1 ]
Ferrari, P. [1 ]
Monteventi, F. [1 ]
机构
[1] ENEA Radiat Protect Inst, I-40135 Bologna, Italy
关键词
Hp(3); Eye-lens dosimetry; HT(eye-lens); Monte Carlo method; Air kerma backscatter factors;
D O I
10.1016/j.radmeas.2011.01.014
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The European Union is funding the ORAMED Contract (Optimization of RAdiation protection for MEDical staff) project that aims at developing methodologies for better assessing and reducing exposures to medical staff for procedures resulting in potentially large doses or complex radiation fields, such as interventional radiology, nuclear medicine and new developments. One of the ORAMED Working Tasks is addressed to the discussion and implementation in the radiation protection practice of the eye lens equivalent dose. The aim of this task group is to develop a personal dosemeter characterized in term of H-p(3). Until now H-p(3) conversion coefficients were not reported in the official recommendations and the available data were calculated for a 30 x 30 x 15 cm(3) slab phantom that is far away to represent the head. A reduced slab phantom, for both calculating the quantities and type testing personal dosemeter in terms of the operational quantity, was previously proposed by ENEA Bologna team. The study demonstrated that a reduced slab phantom is better representative of a real situation, but the angular dependence of H-p(3,alpha ) due to the edges of the slab reduces its applicability. Therefore a better-suited phantom is proposed here. The dosimetric assessment in terms of this quantity is seldom performed in the various workplaces (e.g. hospitals) and therefore a question rises about its usefulness and practical implementation. The present work tries to introduce new elements in the discussion on the quantity H-p(3) and to propose a more suitable theoretical cylindrical phantom (and a corresponding experimental one for the calibration procedures) to better approximate the head in which the eyes are placed. Published by Elsevier Ltd.
引用
收藏
页码:375 / 380
页数:6
相关论文
共 50 条
  • [1] Response of a TLD badge to the new operational quantity Hp(θ): Monte Carlo approach
    Polo, Ivon Oramas
    Santos, William Souza
    de Moraes, Cassiana Viccari
    Nicolucci, Patricia
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 191
  • [2] Personal dosimetry in terms of HP(3):: Monte Carlo and experimental studies
    Ferrari, P.
    Gualdrini, G.
    Bedogni, R.
    Fantuzzi, E.
    Monteventi, F.
    Morelli, B.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 145 - 148
  • [3] On the operational quantity Hp(3) for eye lens dosimetry
    Behrens, R.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (04) : 455 - 464
  • [4] Results of the regional intercomparison exercise for the determination of operational quantity HP(10) in Latin America
    Saravi, M.
    Zaretzky, A.
    Lindner, C.
    Diaz, J.
    Walwyn, G.
    Amorim, R.
    De Souza, D.
    Gregori, B.
    Papadopulos, S.
    Meghzifene, A.
    Ferruz, P.
    Suarez, R. Cruz
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 84 - 87
  • [5] PROPOSAL OF A NEW UPGRADING PROCEDURE FOR MONTE-CARLO EXPERIMENTS
    MEYERORTMANNS, H
    [J]. ZEITSCHRIFT FUR PHYSIK C-PARTICLES AND FIELDS, 1985, 27 (04): : 553 - 558
  • [6] A NEW PROPOSAL FOR MONTE-CARLO SIMULATION OF FERMIONS ON A LATTICE
    ANTHONY, SJ
    SMITH, CHL
    WHEATER, JF
    [J]. PHYSICS LETTERS B, 1982, 116 (04) : 287 - 290
  • [7] DEVELOPMENT OF A NEW IONISATION CHAMBER, FOR HP(10) MEASUREMENT, USING MONTE-CARLO SIMULATION AND EXPERIMENTAL METHODS
    Silva, H.
    Cardoso, J.
    Oliveira, C.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 168 - 172
  • [8] Monte Carlo calculations and experimental results of Bonner spheres systems with a new cylindrical Helium-3 proportional counter
    Muller, H
    Fernández, F
    Van Ryckeghem, L
    Alexandre, P
    Bouassoule, T
    Pochat, JL
    Tomas, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 411 - 415
  • [9] Proposal for a new operational quantity to assess the effective dose in the event of external exposure to photons
    Bouzegzi, K.
    Frahi-Amroun, A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 185
  • [10] QUANTUM MONTE-CARLO VERSUS EXPERIMENTAL RESULTS FOR XXZ CHAINS
    MARCU, M
    MULLER, J
    [J]. PHYSICS LETTERS A, 1987, 119 (09) : 469 - 472