Continuous-flow, on-line monitoring of biospecific interactions using electrospray mass spectrometry

被引:29
|
作者
Hogenboom, AC [1 ]
de Boer, AR [1 ]
Derks, RJE [1 ]
Irth, H [1 ]
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, Div Chem, Fac Sci, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1021/ac010026o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A continuous-flow analytical screening system is presented using electrospray mass spectrometry to measure the interaction of biologically active compounds with soluble affinity proteins. The biochemical detection system is based on a solution-phase, homogeneous assay. In a first step, compounds to be screened (e.g., biotinylated compounds, concentration range 10-1000 nmol/L) are injected into a continuous-flow reaction system and allowed to react with the affinity protein (e.g., streptavidin, concentration range 3-48 nmol/L). Subsequently, a reporter ligand (fluorescein-labeled biotin 96 nmol/L) is added to saturate the remaining free binding sites of the affinity protein and the concentration of unbound reporter ligand is measured using electrospray MS in the selected-ion monitoring mode. The presence of active compounds in the sample results in an increase of the concentration of unbound reporter ligands. The feasibility of a homogeneous MS-based biochemical assay is demonstrated using streptavidin/biotin and anti-digoidgenin/digoxin as model systems. Compared to radioactive or fluorescence-based biochemical assays, the present assay format does not require the synthesis and purification of labels. Various analytical conditions were investigated to determine the ability of MS to measure the biochemical interactions. The availability of a single ligand that can be detected at 10-50 nmol/L concentrations by electrospray MS is sufficient to set up the biochemical assay. For the biospecific interactions studies, detection limits of 10-100 nmol/L were obtained.
引用
收藏
页码:3816 / 3823
页数:8
相关论文
共 50 条
  • [1] On-line monitoring of trihalomethanes in drinking water using continuous-flow purge and cryofocusing gas chromatography-mass spectrometry
    Chen, TC
    Her, GR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) : 229 - 235
  • [2] On-line coupling of high-performance liquid chromatography to a continuous-flow enzyme assay based on electrospray ionization mass spectrometry
    de Boer, AR
    Letzel, T
    van Elswijk, DA
    Lingeman, H
    Niessen, WMA
    Irth, H
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (11) : 3155 - 3161
  • [3] On-line monitoring of Brookhart polymerization by electrospray ionization mass spectrometry
    Santos, Leonardo Silva
    Metzger, Juergen O.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (06) : 898 - 904
  • [4] On-line continuous-flow, multi-protein biochemical assays for the characterization of bioaffinity compounds using electrospray quadrupole time-of-flight mass spectrometry
    Derks, RJE
    Hogenboom, AC
    van der Zwan, G
    Irth, H
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (14) : 3376 - 3384
  • [5] Automatic calibration for on-line process monitoring in continuous-flow systems
    Agudo, M.
    Rios, A.
    Valcarcel, M.
    Danet, A.
    [J]. 1600, (17):
  • [6] Continuous flow reaction monitoring using an on-line miniature mass spectrometer
    Browne, Duncan L.
    Wright, Steven
    Deadman, Benjamin J.
    Dunnage, Samantha
    Baxendale, Ian R.
    Turner, Richard M.
    Ley, Steven V.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (17) : 1999 - 2010
  • [7] On-line monitoring of photolysis reactions using electrospray ionization mass spectrometry coupled with pressurized photoreactor
    Zhang, Hong
    Li, Xiaodi
    Yu, Kai
    Li, Na
    He, Jing
    You, Hong
    Jiang, Jie
    [J]. ANALYTICA CHIMICA ACTA, 2018, 1013 : 36 - 42
  • [8] Membrane permeation continuous-flow isotope ratio mass spectrometry for on-line carbon isotope ratio determination
    Tremblay, Patrice
    Savard, Martine M.
    Smirnoff, Anna
    Paquin, Real
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (14) : 2213 - 2220
  • [9] Reaction screening and optimization of continuous-flow atropine synthesis by preparative electrospray mass spectrometry
    Falcone, Caitlin E.
    Jaman, Zinia
    Wleklinski, Michael
    Koswara, Andy
    Thompson, David H.
    Cooks, R. Graham
    [J]. ANALYST, 2017, 142 (15) : 2836 - 2845
  • [10] On-line monitoring of vacuum dryers using mass spectrometry
    Ende, DJA
    Preigh, MJ
    Hettenbach, K
    Ahlijanian, P
    Ward, HW
    [J]. ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2000, 4 (06) : 587 - 593