A comparison of active power filter control methods in unbalanced and nonsinusoidal conditions

被引:0
|
作者
Marques, GD [1 ]
机构
[1] Univ Tecn Lisboa, Seccao Maquinas Elect & Electron Potencia, Inst Super Tecn, P-1096 Lisbon, Portugal
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Active power filters are used to eliminate current harmonics near nonlinear loads, This paper evaluates four different methods of determining the compensating current for a shunt active filter that is working under nonsymmetrical conditions, The methods compared are the Instantaneous Reactive Power Theory, the Modified Instantaneous Reactive Power Theory, the Synchronous Reference Frame Theory and the Modified Synchronous Reference Frame Theory. The comparison is based on simulation results. In balanced sinusoidal source voltages, the difference between the results obtained by the four methods are of minimum importance, For unbalanced and nonsinusoidal source voltage conditions, the results obtained by the methods referenced are quite different. The synchronous reference frame method had shown the best choice for all situations studied in this paper.
引用
收藏
页码:444 / 449
页数:6
相关论文
共 50 条
  • [1] A shunt active power filter control for unbalanced conditions
    Hosseini, SH
    Haque, MT
    Shahmohammadi, S
    [J]. ICECS 2003: PROCEEDINGS OF THE 2003 10TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-3, 2003, : 830 - 833
  • [2] A Modified IRPT Control Method for a Shunt Active Power Filter for Unbalanced Conditions
    Al-Gahtani, Saad
    Nelms, R. M.
    [J]. 2019 IEEE 28TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2019, : 720 - 727
  • [3] A DSP-Based control algorithm for series active filter for optimized compensation under nonsinusoidal and unbalanced voltage conditions
    George, Sincy
    Agarwal, Vivek
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 302 - 310
  • [4] Adaptive Notch Filter Applied to Hybrid Active Var Compensator under Nonsinusoidal and Unbalanced Conditions
    Ferreira, S. C.
    Gonzatti, R. B.
    Silva, C. H.
    Silva, L. E. B.
    Lambert-Torres, G.
    Silva, L. G. F.
    [J]. 2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 2264 - 2269
  • [5] Comparison of Different Methods of Reference Current Generation for Shunt Active Power Filter Under Balanced And Unbalanced Load Conditions
    Karvekar, Sushil
    Kumbhojkar, Aditi
    [J]. PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 430 - 434
  • [6] A New Voltage Sensorless Control Method for a Shunt Active Power Filter for Unbalanced Conditions
    Al-Gahtani, Saad
    Nelms, R. M.
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2019 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2019,
  • [7] A DSP based optimal algorithm for shunt active filter under nonsinusoidal supply and unbalanced load conditions
    George, Sincy
    Agarwal, Vivek
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) : 593 - 601
  • [8] Control Methods of Active Power Filter
    Ma, Youjie
    Zhao, Jian
    Zhou, Xuesong
    [J]. EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 2342 - +
  • [9] Direct power control of shunt active filter using high selectivity filter (HSF) under distorted or unbalanced conditions
    Mesbahi, Nadhir
    Ouari, Ahmed
    Abdeslam, Djaffar Ould
    Djamah, Tounsia
    Omeiri, Amar
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2014, 108 : 113 - 123
  • [10] Comparison of Active Power Filter Reference Current Detection Methods under Distorted and Unbalanced PCC Voltages
    Popa, D. L.
    Nicolae, P. M.
    [J]. 2014 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE), 2014,