Pulse-mode x-ray beam position monitor prototype for a synchrotron radiation beam line

被引:1
|
作者
Aoyagi, Hideki [1 ]
Furukawa, Yukito [1 ]
Takahashi, Sunao [1 ]
Watanabe, Atsuo [1 ]
机构
[1] Japan Synchrotron Radiat Res Inst JASRI, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
来源
基金
日本学术振兴会;
关键词
D O I
10.1103/PhysRevAccelBeams.24.032803
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
An x-ray beam position monitor (XBPM) prototype that can be operated in pulse mode has been designed and demonstrated. The monitor has a microstripline structure for signal transmission lines and a titanium electrode sputtered on a diamond heat sink as a photocathode. The detection elements of this monitor generate unipolar single pulses with a full width at half maximum of less than 1 ns, allowing a pulse-by-pulse measurement of the synchrotron radiation beam. By synthesizing these pulses, a directly readable position sensitive signal is provided from pulse to pulse. This monitor can be used in the direct current mode in which it exhibits a stability and resolution as good as those of conventional XBPMs. Results of the performance tests of the monitor at the SPring-8 synchrotron radiation beam line are also presented.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A NEW BEAM POSITION MONITOR FOR X-RAY SYNCHROTRON RADIATION FACILITIES
    STEFAN, PM
    SIDDONS, DP
    HASTINGS, JB
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (03): : 598 - 602
  • [2] A SIMPLE PHOTOELECTRON X-RAY-BEAM POSITION MONITOR FOR SYNCHROTRON RADIATION
    HEALD, SM
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 411 - 412
  • [3] New X-ray scattering-based beam position monitor for high power synchrotron radiation
    Revesz, Peter
    Temnykh, Alexander B.
    Pauling, Alan K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 656 - 661
  • [4] IMPLEMENTATION AND TEST OF A SYNCHROTRON RADIATION POSITION MONITOR AT A USER BEAM LINE
    BRODSKY, EL
    KLEMAN, KJ
    ROGERS, G
    RIOUX, D
    PATEL, R
    HOCHST, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 519 - 522
  • [5] A high-precision X-ray beam-position and profile monitor for synchrotron beamlines
    van Silfhout, RG
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 1071 - 1075
  • [6] Parametric X-ray radiation as a beam size monitor
    Takabayashi, Y.
    [J]. PHYSICS LETTERS A, 2012, 376 (35) : 2408 - 2412
  • [7] Beam position measurements of Indus-2 using X-Ray beam position monitor
    Dhamgaye, V. P.
    Lodha, G. S.
    Kane, S. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 659 (01): : 525 - 527
  • [8] X-RAY, SOFT-X-RAY, AND VUV BEAM POSITION MONITOR
    KARLIN, BA
    COWAN, PL
    WOICIK, JC
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 526 - 529
  • [9] A beam position monitor and slit combination for synchrotron radiation
    Xie, YN
    Hu, TD
    Liu, T
    Xian, DC
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 256 - 259
  • [10] Characterization of beryllium and CVD diamond for synchrotron radiation beamline windows and x-ray beam monitor
    Goto, S.
    Takahashi, S.
    Kudo, T.
    Yabashi, M.
    Tamasaku, K.
    Nishino, Y.
    Ishikawa, T.
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS II, 2007, 6705