Metrological Properties Evaluation Of A Chest Wall Simulator During Simulated Quiet Breathing

被引:0
|
作者
Massaroni, Carlo [1 ]
De Leo, Francesca [1 ]
Schena, Emiliano [1 ]
Saccomandi, Paola [1 ]
Silvestri, Sergio [1 ]
机构
[1] Univ Campus Biomedico Roma, Res Unit Measurements & Biomed Instrumentat, Rome, Italy
关键词
Chest Wall Kinematic; Chest Wall Simulator; Metrological assessment; Motion Analysis; Opto-electronic Plethysmography; Quiet Breathing; respiratory volumes; OPTOELECTRONIC PLETHYSMOGRAPHY; KINEMATICS; DISEASE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Opto-electronic Plethysmography (OEP) is a motion analysis system used to measure chest wall kinematics and to indirectly evaluate respiratory volumes during breathing. Its working principle is based on the time-per-time computation of marker displacements placed on the thorax. This work aims at evaluating the metrological properties of a custom made chest wall simulator (CWS) developed to reproduce human chest wall kinematic. The CWS metrological properties were estimated by the comparison of two different motion control strategies of the CWS: the first one is based on the script writing into each motion controller, the second one on macro command sent to the CWS. Three sets of experiments were carried out with the aim to: (i) evaluate precision and accuracy in performing target displacements (i.e., ranging from 2 mm to 8 mm), (ii) evaluate the differences between set and simulated breathing period (i.e., from 10 to 30 breathing per minute), and (iii) assess the movement reproducibility. The precision error, expressed as the ratio between measurement uncertainty and the measured displacement, is always lower than 0.32% (27 mu m) with script-based motion control and 0.25% (6 mu m) with the macro one, for all the target displacements. The difference between the simulated breathing period and the set one is always lower than 0.30 s in both strategies of motion control (percentage error always lower than 15%). Standard deviation between measure, assumed as reproducibility index, showed values always lower than 37 mu m. These performances allows considering both the strategies of control adoptable to be employed for CWS motion control during the OEP performance in further works.
引用
收藏
页码:600 / 605
页数:6
相关论文
共 50 条
  • [1] MOVEMENTS OF CHEST WALL DURING BREATHING
    GODFREY, S
    KAGLE, LE
    PRIDE, NB
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1969, 202 (01): : P11 - &
  • [2] MECHANICAL-PROPERTIES OF LUNGS AND CHEST WALL DURING SPONTANEOUS BREATHING
    NAGELS, J
    LANDSER, FJ
    VANDERLINDEN, L
    CLEMENT, J
    VANDEWOESTIJNE, KP
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1980, 49 (03) : 408 - 416
  • [3] Chest wall motion during tidal breathing
    DeGroote, A
    Wantier, M
    Cheron, G
    Estenne, M
    Paiva, M
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) : 1531 - 1537
  • [4] DEFORMATION OF CHEST WALL DURING BREATHING EFFORTS
    AGOSTONI, E
    MOGNONI, P
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (06) : 1827 - &
  • [5] HUMAN CHEST-WALL FUNCTION WHILE AWAKE AND DURING HALOTHANE ANESTHESIA .1. QUIET BREATHING
    WARNER, DO
    WARNER, MA
    RITMAN, EL
    [J]. ANESTHESIOLOGY, 1995, 82 (01) : 6 - 19
  • [6] CHEST WALL MOVEMENTS DURING FETAL BREATHING IN THE SHEEP
    POORE, ER
    WALKER, DW
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1980, 301 (APR): : 307 - 315
  • [7] Bronchogenic carcinoma invasion of the chest wall: Evaluation with dynamic cine MRI during breathing
    Sakai, S
    Murayama, S
    Murakami, J
    Hashiguchi, N
    Masuda, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) : 595 - 600
  • [8] Chest wall volume changes during inspiratory loaded breathing
    Hostettler, Stefanie
    Illi, Sabine K.
    Mohler, Evelyn
    Aliverti, Andrea
    Spengler, Christina M.
    [J]. RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2011, 175 (01) : 130 - 139
  • [9] Chest Wall Kinematics During Speech Breathing in Tracheoesophageal Speakers
    Bohnenkamp, Todd A.
    Forrest, Karen
    Klaben, Bernice K.
    Stager, Joel
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2012, 121 (01): : 28 - 37
  • [10] Effect of chest wall vibration on the canine diaphragm during breathing
    Leduc, D
    De Troyer, A
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2002, 19 (03) : 429 - 433