Characterization of neonatal seizures by conventional EEG and single-channel EEG

被引:116
|
作者
Shellhaas, Renee A.
Clancy, Robert R.
机构
[1] Childrens Hosp Philadelphia, Div Neurol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Neurol, Dept Pediat, Philadelphia, PA USA
关键词
neonatal seizures; neonatal EEG; amplitude-integrated EEG; cerebral function monitor;
D O I
10.1016/j.clinph.2007.06.061
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To perform a detailed, contemporary temporal-spatial characterization of neonatal seizures (NS) and to compare conventional EEG (CEEG) to single-channel EEG for NS detection. Methods: Digitally recorded CEEGs were reviewed for NS characteristics (quantity, duration, location of onset, peak-to-peak amplitude). The presence and characteristics of each NS were simultaneously noted in a single, derived EEG channel (C-3 -> C-4). Results: Eight hundred fifty-one seizures from 125 CEEGs recorded were analyzed. Mean seizure rate was 7.0 NS/h (range: 0.5-21). Mean seizure burden (percent time CEEG showed NS at any location) was 24.8% (range: 0.7-86.9). Seizure rate was only moderately correlated with seizure burden (Spearman coefficient = 0.58). Eighty-one percent of NS originated from central-temporal or midline vertex electrodes. Seventy-eight percent of NS appeared in the C-3 -> C-4 channel. Conclusions: Accurate measurement of NS burden requires detailed temporal-spatial characterization. The theoretical ceiling of sensitivity for NS detection in the single EEG channel C-3 -> C-4 is high. However, further processing the raw EEG in limited electrode arrays may reduce the sensitivity of NS detection. Significance: CEEG is the gold standard for NS detection. However, reduced montage EEG techniques are increasingly available. This detailed contemporary temporal-spatial characterization of NS evaluates the potential limitations of reduced montage techniques. (C) 2007 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:2156 / 2161
页数:6
相关论文
共 50 条
  • [1] Use of single-channel EEG for neonatal seizure detection
    Shellhaas, Renee A.
    Venkatasubramanian, Anuradha
    Clancy, Robert R.
    [J]. EPILEPSIA, 2006, 47 : 17 - 17
  • [2] Limitations of single-channel EEG on the forehead for neonatal seizure detection
    Quigg, M.
    Leiner, D.
    [J]. JOURNAL OF PERINATOLOGY, 2009, 29 (08) : 588 - 588
  • [3] Limitations of single-channel EEG on the forehead for neonatal seizure detection
    Wusthoff, Courtney
    Shellhaas, R. A.
    Clancy, R. R.
    [J]. EPILEPSIA, 2007, 48 : 184 - 184
  • [4] Limitations of single-channel EEG on the forehead for neonatal seizure detection
    Wusthoff, C. J.
    Shellhaas, R. A.
    Clancy, R. R.
    [J]. JOURNAL OF PERINATOLOGY, 2009, 29 (03) : 237 - 242
  • [5] Limitations of single-channel EEG on the forehead for neonatal seizure detection
    M Quigg
    D Leiner
    [J]. Journal of Perinatology, 2009, 29 : 588 - 588
  • [6] Limitations of single-channel EEG on the forehead for neonatal seizure detection
    C J Wusthoff
    R A Shellhaas
    R R Clancy
    [J]. Journal of Perinatology, 2009, 29 : 237 - 242
  • [7] Intracranial EEG Validation of Single-Channel Subgaleal EEG for Seizure Identification
    Pacia, Steven, V
    Doyle, Werner K.
    Friedman, Daniel
    Bacher, Daniel H.
    Kuzniecky, Ruben, I
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2022, 39 (04) : 283 - 288
  • [8] Novel ML-Based Algorithm for Detecting Seizures from Single-Channel EEG
    Dweiri, Yazan M.
    Al-Omary, Taqwa K.
    [J]. NEUROSCI, 2024, 5 (01): : 59 - 70
  • [9] Classification of single-channel EEG signals for epileptic seizures detection based on hybrid features
    Lu, Yanan
    Ma, Yu
    Chen, Chen
    Wang, Yuanyuan
    [J]. TECHNOLOGY AND HEALTH CARE, 2018, 26 : S337 - S346
  • [10] Study on Single-Channel EEG Pattern Induced by Acupuncture
    Zhang, Tinglin
    Li, Guang
    Liljenstrom, Hans
    [J]. ADVANCES IN COGNITIVE NEURODYNAMICS (V), 2016, : 485 - 491