Side effects of antiscalants on biofouling of reverse osmosis membranes in brackish water desalination

被引:74
|
作者
Sweity, Amer [1 ]
Zere, Tesfalem Rezene [1 ]
David, Inbal [2 ]
Bason, Sarit [2 ]
Oren, Yoram [1 ]
Ronen, Zeev [1 ]
Herzberg, Moshe [1 ]
机构
[1] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Albert Katz Int Sch Desert Studies, Zuckerberg Inst Water Res, IL-84990 Sede Boqer, Israel
[2] Mekorot Water Co Ltd, Tel Aviv, Israel
关键词
Biofouling; Antiscalants; Reverse osmosis; Desalination; Brackish water; AGRICULTURAL DRAINAGE WATER; POLYMERIC SUBSTANCES EPS; RO MEMBRANES; SEAWATER DESALINATION; WASTE-WATER; PRESSURE; SYSTEMS; REUSE; PLANT; NF;
D O I
10.1016/j.memsci.2015.02.003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, we investigated the contribution of antiscalants to biofouling of reverse osmosis (RO) membranes in brackish water desalination process. Both the physico-chemical effects of the antiscalants on the initial attachment of bacterial cells to RO membrane surfaces, as well as their nutritional contribution to biofilm growth were analyzed. A bacterial deposition experiment on ESPA-2 RD membrane was conducted using Pseudomonas fluorescens, and the two polyphosphonate- and polyacrylate-based antiscalants. Both the model bacterium and the ESPA-2 RD membranes were treated with feed brackish water with and without antiscalants. The nutritional contribution of these antiscalants to biofilm growth was investigated by growing biofilms in packed bed biofilm reactors in the presence and absence of the antiscalants. In the presence of both antiscalants, biofilm development was enhanced in comparison to the control. Eventually, the impact of the antiscalant-induced biofilm growth on the performance of RD membranes was investigated in a crossflow RD filtration unit under typical brackish water desalination conditions. Significant membrane biofouling was detected in the presence of the antiscalants compared to the case where no antiscalant was used, accompanied by higher flux decline and salt passage. RD membrane modules were also utilized in an industrial and pilot desalination plants to test the effect of the polyacrylate-based antiscalant. Similar behavior was observed on both scales of membrane operation, with polyacrylate inducing biofilm growth. We assert that the two types of antiscalant induce biofilm formation on RD membrane surfaces through two different mechanisms: while polyacrylates increase bacterial initial attachment by altering membrane physicochemical properties, mainly increasing membrane hydrophobicity, polyphosphonates increase biofilm growth under phosphorous limiting conditions by providing the cells with the phosphorous they lack. Thus, the selection of the type and dosage of antiscalant should take into account the associated contribution to membrane biofouling propensity. (C) 2015 Elsevier By. All rights reserved.
引用
收藏
页码:172 / 187
页数:16
相关论文
共 50 条
  • [1] Desalination: Antiscalants keep the water flowing in reverse osmosis
    Cartmell, David
    Holmes, Mark
    [J]. FILTRATION + SEPARATION, 2012, 49 (05) : 22 - 24
  • [2] High-flux reverse osmosis membranes for brackish water desalination
    Ho, W. S. Winston
    Zhao, L.
    Chang, C. Y.
    [J]. EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 13 - 13
  • [3] Desalination of brackish water by nanofiltration and reverse osmosis
    Mohsen, MS
    Jaber, JO
    Afonso, MD
    [J]. DESALINATION, 2003, 157 (1-3) : 167 - 167
  • [4] Biofouling in reverse osmosis membranes for seawater desalination: Phenomena and prevention
    Matin, Asif
    Khan, Z.
    Zaidi, S. M. J.
    Boyce, M. C.
    [J]. DESALINATION, 2011, 281 : 1 - 16
  • [5] Preliminary evaluation of new green antiscalants for reverse osmosis water desalination
    Pervov, Alexey G.
    Andrianov, Alexey P.
    Danilycheva, Maria N.
    [J]. WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2018, 18 (01): : 167 - 174
  • [6] The influence of antiscalants on biofouling of RO membranes in seawater desalination
    Sweity, Amer
    Oren, Yoram
    Ronen, Zeeu
    Herzberg, Moshe
    [J]. WATER RESEARCH, 2013, 47 (10) : 3389 - 3398
  • [7] Biofouling characteristics of reverse osmosis membranes during dyeing wastewater desalination
    Shi, Jianhong
    Su, Yinglong
    Du, Chongxin
    Xie, Bing
    [J]. DESALINATION AND WATER TREATMENT, 2019, 147 : 31 - 37
  • [8] Optimization of Multitrain Brackish Water Reverse Osmosis (BWRO) Desalination
    Li, Mingheng
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (09) : 3732 - 3739
  • [9] An innovative hybridization of electrodialysis with reverse osmosis for brackish water desalination
    Generous, Muhammad M.
    Qasem, Naef A. A.
    Zubair, Syed M.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2021, 245
  • [10] Reverse osmosis membrane performance for desalination of Algerian brackish water
    Bouchareb, Abderrezak
    Metaiche, Mehdi
    Lounici, Hakim
    Khoudja, Hakim Djafer
    Lefkir, Abdelwahab
    Drouiche, Nadjib
    [J]. DESALINATION AND WATER TREATMENT, 2019, 151 : 9 - 19