Calibrant-loaded paper-based analytical devices for standard addition quantitative assays

被引:14
|
作者
Kappi, Foteini A. [1 ]
Tsogas, George Z. [1 ]
Christodouleas, Dionysios C. [2 ]
Giokas, Dimosthenis L. [1 ]
机构
[1] Univ Ioannina, Dept Chem, Ioannina 45110, Greece
[2] Univ Massachusetts, Dept Chem, Lowell, MA 01854 USA
关键词
Paper-based devices; Standard addition; Calibrant-loaded devices; Nonlinear calibration; MICROFLUIDIC DEVICES; PATTERNED-PAPER; COLORIMETRIC DETECTION; NONLINEAR CALIBRATION; ANALYTICAL-CHEMISTRY; SELF-CALIBRATION; PROBES; GOLD; TIME; NANOPARTICLES;
D O I
10.1016/j.snb.2017.07.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes a new approach for performing analytical assays on paper-based analytical devices that relies on the principles of multiple standard additions calibration, and uses calibrant-loaded paper devices. Calibrant-loaded devices have multiple sensing areas pre-loaded with an excess amount of the necessary colorimetric reagents and known amounts (standard solutions) of the tested analyte; thus, a colored product is developed before analysis in each sensing area. After sample addition, the analytical signal from each sensing area corresponds to the total concentration of the analyte, which is the sum of the concentration of the analyte in the tested sample plus the known amount of the analyte pre-stored in the device. The combined signal retrieved from each sensing zone is plotted to form a standard addition calibration curve that is used to calculate the concentration of the analyte in the sample using linear or non-linear models (i.e., first or higher order polynomials). This new approach could reduce the influence of matrix effects, paper inhomogeneity and environmental conditions on the results, and it could simplify the analysis as it may eliminate the steps associated with on-spot calibration that should ideally be performed using standard solutions that are prepared or transported in-situ. The utility and applicability of this approach is demonstrated as proof-of-concept on five assays (i.e., for the determination of iron, protein, hydrogen peroxide, acetic acid and carbonate ions) that use different reactions (i.e. complexation, oxidation and neutralization). This work provides a demonstration of a multiple standard addition methodology applied on calibrant-loaded paper-based analytical devices and illustrate its use as a sample-in result-out tool for point-of-use applications. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:860 / 867
页数:8
相关论文
共 50 条
  • [1] Single-point calibration and standard addition assays on calibrant-loaded paper-based analytical devices
    Giannoulas, George
    Tsogas, George Z.
    Giokas, Dimosthenis L.
    TALANTA, 2019, 201 : 149 - 155
  • [2] Paper-based standard addition assays
    Chaplan, Cory A.
    Mitchell, Haydn T.
    Martinez, Andres W.
    ANALYTICAL METHODS, 2014, 6 (05) : 1296 - 1300
  • [3] Environmental effects on assays in microfluidic paper-based analytical devices
    Allan, Zachary C.
    Fisher, Matthew A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [4] "Paper-based Analytical Devices"
    不详
    Analytical Sciences, 2017, 33 (3) : 259 - 259
  • [5] Paper-based Analytical Devices
    Hisamoto, Hideaki
    ANALYTICAL SCIENCES, 2017, 33 (07) : 753 - 753
  • [6] Paper-based analytical devices
    Citterio, Daniel
    Kaneta, Takashi
    Analytical Sciences, 2018, 34 (01) : 5 - 6
  • [7] Paper-based Analytical Devices
    Hideaki Hisamoto
    Analytical Sciences, 2017, 33 : 753 - 753
  • [8] Laminated paper-based analytical devices (LPAD): fabrication, characterization, and assays
    Cassano, Christopher L.
    Fan, Z. Hugh
    MICROFLUIDICS AND NANOFLUIDICS, 2013, 15 (02) : 173 - 181
  • [9] Laminated paper-based analytical devices (LPAD): fabrication, characterization, and assays
    Christopher L. Cassano
    Z. Hugh Fan
    Microfluidics and Nanofluidics, 2013, 15 : 173 - 181
  • [10] Quantitative biomarker assay with microfluidic paper-based analytical devices
    Xu Li
    Junfei Tian
    Wei Shen
    Analytical and Bioanalytical Chemistry, 2010, 396 : 495 - 501