Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region

被引:12
|
作者
Haji, Sara [1 ]
Alla, Aicha Ait [1 ]
Noureddine, Slimani [1 ]
Ben Haddad, Mohamed [1 ]
Moukrim, Abdellatif [2 ]
机构
[1] Ibn Zohr Univ, Fac Sci, Lab Aquat Syst Marine & Continental Ecosyst, Agadir, Morocco
[2] Abdelamalek Essadi Univ, Fac Sci, Tetouan, Morocco
来源
JOURNAL OF ECOLOGICAL ENGINEERING | 2021年 / 22卷 / 06期
关键词
wastewater; Morocco; physicochemical parameters; activated sludge; Aourir; bacteriological param-eters; treatment plants; REUSE; FILTRATION; RESISTANCE; BACTERIA; SEWAGE; LAGOON; SOIL;
D O I
10.12911/22998993/137360
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30 degrees C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 mu S/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
引用
收藏
页码:83 / 98
页数:16
相关论文
共 9 条
  • [1] Antibiotic resistance and survival of faecal coliforms in activated sludge system in a semi-arid region (Beni Mellal, Morocco)
    S. Fars
    K. Oufdou
    A. Nejmeddine
    L. Hassani
    A. Ait. Melloul
    K. Bousselhaj
    O. Amahmid
    K. Bouhoum
    H. Lakmichi
    N. Mezrioui
    World Journal of Microbiology and Biotechnology, 2005, 21 : 493 - 500
  • [2] Antibiotic resistance and survival of faecal coliforms in activated sludge system in a semi-arid region (Beni Mellal, Morocco)
    Fars, S
    Oufdou, K
    Nejmeddine, A
    Hassani, L
    Melloul, AA
    Bousselhaj, K
    Amahmid, O
    Bouhoum, K
    Lakmichi, H
    Mezrioui, N
    WORLD JOURNAL OF MICROBIOLOGY & BIOTECHNOLOGY, 2005, 21 (04): : 493 - 500
  • [3] Hydroponic wheat production using fresh water and treated wastewater under the semi-arid region
    Al Hamedi, Fatima Hasan Abdulla Ahmed
    Karthishwaran, Kandhan
    Alyafei, Mohammed Abdul Mohsen
    EMIRATES JOURNAL OF FOOD AND AGRICULTURE, 2021, 33 (02): : 178 - 186
  • [4] Study of Seasonal variation and Index Based Assessment of Water Quality and Pollution in Semi-Arid Region of Morocco
    El Morabet, Rachida
    Barhazi, Larbi
    Khan, Roohul Abad
    Hejjaj, Abdessamad
    Harrara, Rachid
    Bouhafa, Soufian
    Khan, Amadur Rahman
    Khan, Nadeem A.
    Yeremenko, Sergiy
    ECOLOGICAL QUESTIONS, 2021, 32 (04)
  • [5] Mapping soil suitability using phenological information derived from MODIS time series data in a semi-arid region: A case study of Khouribga, Morocco
    Ismaili, Maryem
    Krimissa, Samira
    Namous, Mustapha
    Abdelrahman, Kamal
    Boudhar, Abdelghani
    Edahbi, Mohamed
    Lebrini, Youssef
    Htitiou, Abdelaziz
    Maimouni, Soufiane
    Benabdelouhab, Tarik
    HELIYON, 2024, 10 (02)
  • [6] Mapping the impact of quarrying on karst groundwater resources in a semi-arid region using GIS and remote sensing: A case study of the agourai aquifer, Middle atlas, Morocco
    Mouloudi, Abdelmoula
    Mili, El Mostafa
    El Faleh, El Mati
    Said, Brahim Ait
    Mehdaoui, Radouan
    JOURNAL OF AFRICAN EARTH SCIENCES, 2025, 227
  • [7] Study of the weekly irrigation cycle of a cultivated field in a semi-arid area (Marrakech region, Morocco) by using CR-39 and LR-115 II track detectors and radon as a natural tracer
    Misdaq, M. A.
    Essaouif, Z.
    RADIATION MEASUREMENTS, 2007, 42 (03) : 431 - 440
  • [8] Cytotoxic and genotoxic evaluation and chemical characterization of sewage treated using activated sludge and a floating emergent-macrophyte filter in a municipal wastewater treatment plant: a case study in Southern Brazil
    Angélica Goldoni
    Camila Golfeto
    Jane B. Teixeira
    Gislaine Blumm
    Camila M. Wilhelm
    Franko Telöken
    Eloisa Bianchi
    Jairo L. Schmitt
    Günther Gehlen
    Marco Antonio S. Rodrigues
    Luciano Basso da Silva
    Environmental Earth Sciences, 2014, 72 : 1503 - 1509
  • [9] Cytotoxic and genotoxic evaluation and chemical characterization of sewage treated using activated sludge and a floating emergent-macrophyte filter in a municipal wastewater treatment plant: a case study in Southern Brazil
    Goldoni, Angelica
    Golfeto, Camila
    Teixeira, Jane B.
    Blumm, Gislaine
    Wilhelm, Camila M.
    Teloeken, Franko
    Bianchi, Eloisa
    Schmitt, Jairo L.
    Gehlen, Guenther
    Rodrigues, Marco Antonio S.
    da Silva, Luciano Basso
    ENVIRONMENTAL EARTH SCIENCES, 2014, 72 (05) : 1503 - 1509