Radioluminescence of silica optical fibre scintillators for real-time industrial radiation dosimetry

被引:6
|
作者
Oresegun, Adebiyi [1 ]
Basaif, A. [1 ]
Tarif, Zubair H. [1 ,2 ]
Abdul-Rashid, H. A. [1 ]
Hashim, Siti Aiasah [3 ]
Bradley, D. A. [4 ,5 ]
机构
[1] Multimedia Univ, Fac Engn, Fibre Opt Res Ctr, Jalan Multimedia, Cyberjaya 63100, Malaysia
[2] Lumisysns Technol Sdn Bhd, Cyberjaya 63100, Selangor, Malaysia
[3] Agensi Nuklear Malaysia, Alurtron Electron Beam Irradiat Ctr, Kajang 43000, Selangor, Malaysia
[4] Sunway Univ, Sch Engn & Technol, Ctr Appl Phys & Radiat Technol, Pj 46150, Malaysia
[5] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
关键词
Radioluminescence; Real-time dosimetry; Optical fibre scintillator; Industrial radiation; SI NANOCRYSTALS; LUMINESCENCE; PHOTOLUMINESCENCE; DEFECTS; CENTERS; DICHROMATE; GLASSES; BAND;
D O I
10.1016/j.radphyschem.2021.109684
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dosimetry systems are important in any radiation facility to ensure quality, safety, validation, qualification and quality control of established and new processes, including at industrial radiation facilities. We present a study of silica optical fibre as scintillators for industrial radiation dosimetry using Radioluminescence (RL). The RL technique provides for a remote and real-time dosimetry measurement in such a high dose environment. This study establishes the dosimetric characteristics of two variants of pure silica optical fibre, low and high hydroxyl (OH) when exposed to industrial radiation levels. The samples were exposed to a linear accelerator, with doses in the order of tens of kGy (from 10 kGy through to 70 kGy in individual exposures). The performance parameters observed during the study include the RL emission spectrum, emission intensity and emission linearity with exposure dose. The RL spectrum demonstrated a central wavelength of 650 nm and 550 nm for the high and low OH scintillators, respectively. RL intensity was observed to increase with exposed dose, a result of recombination of ionizing radiation generated electron-hole pairs. The RL intensity relation with exposed dose indicated a linear response, with the higher OH sample showing the greater slope, indicating greater sensitivity. The overall results indicate the potential use of pure silica optical fibre as scintillators for remote and real-time industrial radiation dosimetry.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Radioluminescence of cylindrical and flat Ge-doped silica optical fibers for real-time dosimetry applications
    Oresegun, Adebiyi
    Tarif, Zubair H.
    Ghassan, Louay
    Zin, Hafiz
    Abdul-Rashid, Hairul Azhar
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2021, 176 (176)
  • [2] Time-Resolved Radioluminescence Dosimetry Applications and the Influence of Ge Dopants In Silica Optical Fiber Scintillators
    Tarif, Zubair H.
    Oresegun, Adebiyi
    Abubakar, Auwal
    Basaif, Azmi
    Zin, Hafiz M.
    Choo, Kan Yeep
    Ibrahim, Siti A.
    Abdul-Rashid, Hairul Azhar
    Bradley, David A.
    QUANTUM BEAM SCIENCE, 2022, 6 (02)
  • [3] Real-time radiation dosimetry using P-doped silica optical fiber
    Zubair, H. T.
    Oresegun, A.
    Rahman, A. K. M. Mizanur
    Ung, N. M.
    Sharif, K. A. Mat
    Zulkifli, M. I.
    Yassin, S. Z. Muhd
    Maah, M. J.
    Yusoff, Z.
    Abdul-Rashid, H. A.
    Bradley, D. A.
    Omar, Nasr Y. M.
    MEASUREMENT, 2019, 146 : 119 - 124
  • [4] Ge-doped silica optical fibre for Time Resolved Radiation Dosimetry
    Basaif, A.
    Oresegun, Adebiyi
    Tarif, Zubair H.
    Zin, Hafiz
    Choo, K. Y.
    Ibrahim, S. A.
    Abdul-Rashid, H. A.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [5] Optical Fibre Luminescence Sensor for Real-time LDR Brachytherapy Dosimetry
    Woulfe, P.
    O'Keeffe, S.
    Sullivan, F. J.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XVIII, 2018, 10488
  • [6] Optical Fibre Luminescence Sensor for Real-time LDR Brachytherapy Dosimetry
    Woulfe, P.
    O'Keeffe, S.
    Sullivan, F. J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S988 - S989
  • [7] Optical Fibre Luminescence Sensor for Real-time LDR Brachytherapy Dosimetry
    Woulfe, P.
    Sullivan, F. J.
    O'Keeffe, S.
    SIXTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2016, 9916
  • [8] Real-time dosimetry with Yb-doped silica optical fibres
    Veronese, Ivan
    Chiodini, Norberto
    Cialdi, Simone
    d'Ippolito, Eduardo
    Fasoli, Mauro
    Gallo, Salvatore
    La Torre, Stefano
    Mones, Eleonora
    Vedda, Anna
    Loi, Gianfranco
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (10): : 4218 - 4236
  • [9] Germanium-doped optical fiber for real-time radiation dosimetry
    Rahman, A. K. M. Mizanur
    Zubair, H. T.
    Begum, Mahfuza
    Abdul-Rashid, H. A.
    Yusoff, Z.
    Ung, N. M.
    Mat-Sharif, K. A.
    Abdullah, W. S. Wan
    Mahdiraji, Ghafour Amouzad
    Amin, Y. M.
    Maah, M. J.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 170 - 175
  • [10] A competitive radioluminescence material - LiF:Mg,Cu,P for real-time dosimetry
    Zhang, Siyuan
    Tang, Kaiyong
    Fan, Haijun
    Fu, Li
    RADIATION MEASUREMENTS, 2022, 151