A Systematic Review of Image Quality, Diagnostic Value and Radiation Dose of Coronary CT Angiography Using Iterative Reconstruction Compared to Filtered Back Projection in the Diagnosis of Coronary Artery Disease

被引:3
|
作者
Al Shammakhi, Ahmed [1 ,2 ]
Sun, Zhonghua [1 ]
机构
[1] Curtin Univ, Dept Imaging & Appl Phys, Discipline Med Imaging, Perth, WA 6845, Australia
[2] Armed Forces Hosp, Dept Radiol, Muscat, Oman
关键词
Coronary CT Angiography; Iterative Reconstruction; Filtered Back-Projection; Image Quality; Radiation Dose; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; REDUCTION; IMPACT; NOISE; ASIR;
D O I
10.1166/jmihi.2015.1364
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study was to perform a systematic review of the image quality, diagnostic value and radiation dose of coronary CT angiography performed with iterative reconstruction (IR) when compared to the standard filtered back-projection (FBP) techniques. A search of Pubmed/Medline and Science direct databases for English literature was performed to identify studies comparing IR and FBP techniques used in coronary CT angiography in the diagnosis of patients with suspected coronary artery disease. Qualitative and quantitative assessment of image quality and effective radiation dose associated with coronary CT angiography were analyzed and compared between the two reconstruction algorithms to determine if there are any significant differences. Twenty-nine studies met selection criteria and were included in the analysis. In comparison with FBP; coronary CT angiography with IR showed improvement in image quality in terms of qualitative and quantitative image analysis. Furthermore, the IR technique results in higher segment assessability (89.5% vs. 85.8%) and high sensitivity, specificity and diagnostic accuracy (95.2%, 96.5% and 96.3% and 94.2%, and 94.3%) (although no significant difference between IR and FBP reconstructions) but with significantly lower radiation dose than that with use of FBP (3.1 mSv vs. 5.8 mSv). Iterative reconstruction technique leads to noise reduction and subsequently improvement in image quality in coronary CT angiography with significantly lower radiation dose. It could be used as a feasible alternative to the standard filtered back projection in coronary CT angiography, although further studies are needed to confirm its diagnostic value.
引用
收藏
页码:96 / 102
页数:7
相关论文
共 50 条
  • [1] Coronary CT Angiography with Use of Iterative Reconstruction Algorithm in Coronary Stenting: A Systematic Review of Image Quality, Diagnostic Value and Radiation Dose
    Al Shammakhi, Ahmed
    Sun, Zhonghua
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (01) : 103 - 109
  • [2] Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review
    Abdullah, Kamarul Amin
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 459 - 468
  • [3] CT coronary angiography: Image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection
    Wang, R.
    Schoepf, U. J.
    Wu, R.
    Gibbs, K. P.
    Yu, W.
    Li, M.
    Zhang, Z.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (03) : 272 - 278
  • [4] Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique—comparison with traditional filtered back projection
    Antonio Moscariello
    Richard A. P. Takx
    U. Joseph Schoepf
    Matthias Renker
    Peter L. Zwerner
    Terrence X. O’Brien
    Thomas Allmendinger
    Sebastian Vogt
    Bernhard Schmidt
    Giancarlo Savino
    Christian Fink
    Lorenzo Bonomo
    Thomas Henzler
    [J]. European Radiology, 2011, 21
  • [5] Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection
    Wang, Rui
    Schoepf, U. Joseph
    Wu, Runze
    Reddy, Ryan P.
    Zhang, Chuanchen
    Yu, Wei
    Liu, Yi
    Zhang, Zhaoqi
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3141 - 3145
  • [6] Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection
    Moscariello, Antonio
    Takx, Richard A. P.
    Schoepf, U. Joseph
    Renker, Matthias
    Zwerner, Peter L.
    O'Brien, Terrence X.
    Allmendinger, Thomas
    Vogt, Sebastian
    Schmidt, Bernhard
    Savino, Giancarlo
    Fink, Christian
    Bonomo, Lorenzo
    Henzler, Thomas
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (10) : 2130 - 2138
  • [7] Comparisons of Image Quality and Radiation Dose Between Iterative Reconstruction and Filtered Back Projection Reconstruction Algorithms in 256-MDCT Coronary Angiography
    Hou, Yang
    Liu, Xin
    Xv, Shu
    Guo, Wenli
    Guo, Qiyong
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) : 588 - 594
  • [8] Diagnostic Accuracy of Coronary CT Angiography: Comparison of Filtered Back Projection and Iterative Reconstruction With Different Strengths
    Wang, Rui
    Schoepf, U. Joseph
    Wu, Runze
    Nance, John W., Jr.
    Lv, Biao
    Yang, Hua
    Li, Fang
    Lu, Dongxu
    Zhang, Zhaoqi
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (02) : 179 - 184
  • [9] Coronary CT Angiography in Obese Patients: Comparison of Iterative Reconstruction and Filtered Back Projection for Their Effect on Image Noise and Potential for Radiation Dose Reduction
    Joshi, G.
    Schoepf, U.
    Spears, Reid J.
    Mills, J.
    Vliegenthart, R.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [10] Evaluation of Heavily Calcified Vessels with Coronary CT Angiography: Comparison of Iterative and Filtered Back Projection Image Reconstruction
    Renker, Matthias
    Nance, John W., Jr.
    Schoepf, U. Joseph
    O'Brien, Terrence X.
    Zwerner, Peter L.
    Meyer, Mathias
    Kerl, J. Matthias
    Bauer, Ralf W.
    Fink, Christian
    Vogl, Thomas J.
    Henzler, Thomas
    [J]. RADIOLOGY, 2011, 260 (02) : 390 - 399