Comparison of analyses of urinary 8-hydroxy-2′-deoxyguanosine by isotope-dilution liquid chromatography with electrospray tandem mass spectrometry and by enzyme-linked immunosorbent assay

被引:110
|
作者
Hu, CW
Wu, MT
Chao, MR
Pan, CH
Wang, CJ
Swenberg, JA
Wu, KY
机构
[1] Natl Hlth Res Inst, Div Environm Hlth & Occupat Med, Kaohsiung, Taiwan
[2] Chun Shan Med Univ, Dept Publ Hlth, Taichung, Taiwan
[3] Kaohsiung Med Univ, Grad Inst Occupat Safety & Hlth, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Dept Occupat Med, Kaohsiung, Taiwan
[5] Chung Shan Med Univ, Dept Occupat Safety & Hlth, Taichung, Taiwan
[6] Council Labor, Inst Occupat Safety & Hlth, Taipei, Taiwan
[7] Univ N Carolina, Dept Environm Sci & Engn, Chapel Hill, NC 27599 USA
[8] Univ N Carolina, Curriculum Toxicol, Chapel Hill, NC 27599 USA
关键词
D O I
10.1002/rcm.1367
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive and selective method, using isotope-dilution liquid chromatography with tandem mass spectrometry (LC/MS/MS), for quantification of urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG), an important biomarker of oxidative stress, was developed and compared with a method using an enzyme-linked immunosorbent assay (ELISA). The synthesis of N-15(5)-8-OHdG is described. In this study, 140 urine samples were collected from workers in a coke oven plant, including samples from 49 control workers and 91 workers who had been occupationally exposed to polyaromatic hydrocarbons (PAHs). The major urinary metabolite of PAHs, 1-hydroxypyrene (1-OHP), was measured for the exposed workers. Results from the present study showed a significant correlation between these two measurements for determination of 8-OHdG (p < 0.05, r(2) = 0.70). However, only the LC/MS/MS measurements of urinary levels of 8-OHdG showed a significant difference between the exposed and the control subjects (p < 0.05). The ELISA method failed to demonstrate this difference. Furthermore, only by using the LC/MS/MS method was a significant correlation observed between the urinary levels of 1-OHP and 8-OHdG. These findings suggest that a highly specific and sensitive analytical method such as isotope-dilution LC/MS/MS is extremely important and necessary for accurate measurement and a comprehensive study of oxidative stress in human subjects. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 50 条
  • [1] Comparison between high-performance liquid chromatography and enzyme-linked Immunosorbent assay for the determination of 8-hydroxy-2′-deoxyguanosine in human urine
    Shimoi, K
    Kasai, H
    Yokota, N
    Toyokuni, S
    Kinae, N
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2002, 11 (08) : 767 - 770
  • [2] Determination of 8-Hydroxy-2′-deoxyguanosine in Urine by Liquid Chromatography–Electrospray Ionization–Mass Spectrometry
    Hiroshi Moriwaki
    [J]. Analytical Sciences, 2000, 16 : 105 - 106
  • [3] A method to determine 8-hydroxy-2′-deoxyguanosine by using nano liquid chromatography-electrospray tandem mass spectrometry
    Harri, M
    Peltonen, K
    Tornaeus, J
    Hesso, A
    Savela, K
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 2004, 36 : S82 - S82
  • [4] Simultaneous determination of urinary parabens, bisphenol A, triclosan, and 8-hydroxy-2′-deoxyguanosine by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Lu Ren
    Jianzhang Fang
    Guihua Liu
    Jianqing Zhang
    Zhou Zhu
    Honghe Liu
    Kai Lin
    Huimin Zhang
    Shaoyou Lu
    [J]. Analytical and Bioanalytical Chemistry, 2016, 408 : 2621 - 2629
  • [5] Simultaneous determination of urinary parabens, bisphenol A, triclosan, and 8-hydroxy-2'-deoxyguanosine by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Ren, Lu
    Fang, Jianzhang
    Liu, Guihua
    Zhang, Jianqing
    Zhu, Zhou
    Liu, Honghe
    Lin, Kai
    Zhang, Huimin
    Lu, Shaoyou
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (10) : 2621 - 2629
  • [6] Comparing the Relative Oxidative DNA Damage Caused by Various Arsenic Species by Quantifying Urinary Levels of 8-Hydroxy-2'-Deoxyguanosine with Isotope-Dilution Liquid Chromatography/Mass Spectrometry
    Wu, Jin-Zhu
    Ho, Paul C.
    [J]. PHARMACEUTICAL RESEARCH, 2009, 26 (06) : 1525 - 1533
  • [7] Comparing the Relative Oxidative DNA Damage Caused by Various Arsenic Species by Quantifying Urinary Levels of 8-Hydroxy-2′-Deoxyguanosine with Isotope-Dilution Liquid Chromatography/Mass Spectrometry
    Jin-Zhu Wu
    Paul C. Ho
    [J]. Pharmaceutical Research, 2009, 26 : 1525 - 1533
  • [8] Measuring asymmetric dimethylarginine (ADMA) in CKD: a comparison between enzyme-linked immunosorbent assay and liquid chromatography-electrospray tandem mass spectrometry
    Pecchini, Paola
    Malberti, Fabio
    Mieth, Maren
    Quinn, Robert
    Tripepi, Giovanni
    Mallamaci, Francesca
    Maas, Renke
    Zoccali, Carmine
    Ravani, Pietro
    [J]. JOURNAL OF NEPHROLOGY, 2012, 25 (06) : 1016 - 1022
  • [9] Analysis of 8-hydroxy-2′-deoxyguanosine in urine using high-performance liquid chromatography-electrospray tandem mass spectrometry
    Harri, Minna
    Kasai, Hiroshi
    Mori, Toshiaki
    Tornaeus, Jarkko
    Savela, Kirsti
    Peltonen, Kimmo
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 242 - 246
  • [10] Determination of 8-hydroxy-2′-deoxyguanosine in urine by liquid chromatography-electrospray ionization-mass spectrometry
    Moriwaki, H
    [J]. ANALYTICAL SCIENCES, 2000, 16 (02) : 105 - 106