CO2 Plume Management in Saline Reservoir Sequestration

被引:5
|
作者
Frailey, Scott M. [1 ]
Finley, Robert J. [1 ]
机构
[1] Univ Illinois, Illinois State Geol Survey, Urbana, IL USA
关键词
geologic sequestration; plume distribution; storage engineering;
D O I
10.1016/j.egypro.2011.02.372
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A significant difference between injecting CO2 into saline aquifers for sequestration and injecting fluids into oil reservoirs or natural gas into aquifer storage reservoirs is the availability and use of other production and injection wells surrounding the primary injection well(s). Of major concern for CO2 sequestration using a single well is the distribution of pressure and CO2 saturation within the injection zone. Pressure is of concern with regards to caprock integrity and potential migration of brine or CO2 outside of the injection zone, while CO2 saturation is of interest for storage rights and displacement efficiency. For oil reservoirs, the presence of additional wells is intended to maximize oil recovery by injecting CO2 into the same hydraulic flow units from which the producing wells are withdrawing fluids. Completing injectors and producers in the same flow unit increases CO2 throughput, maximizes oil displacement efficiency, and controls pressure buildup. Additional injectors may surround the CO2 injection well and oil production wells in order to provide external pressure to these wells to prevent the injected CO2 from migrating from the pattern between two of the producing wells. Natural gas storage practices are similar in that to reduce the amount of "cushion" gas and increase the amount of cycled or working gas, edge wells may be used for withdrawal of gas and center wells used for gas injection. This reduces loss of gas to the formation via residual trapping far from the injection well. Moreover, this maximizes the natural gas storage efficiency between the injection and production wells and reduces the areal extent of the natural gas plume. Proposed U. S. EPA regulations include monitoring pressure and suggest the "plume" may be defined by pressure in addition to the CO2 saturated area. For pressure monitoring, it seems that this can only be accomplished by injection zone monitoring wells. For pressure, these wells would not need to be very close to the injection well, compared to monitoring wells intended to measure CO2 saturation via fluid sampling or cased-hole well logs. If pressure monitoring wells become mandated, these wells could be used for managing the CO2 saturation and aquifer pressure distribution. To understand the relevance and effectiveness of producing and injecting brine to improve storage efficiency, direct the plume to specific pore space, and redistribute the pressure, numerical models of CO2 injection into aquifers are used. Simulated cases include various aquifer properties at a single well site and varying the number and location of surrounding wells for plume management. Strategies in terms of completion intervals can be developed to effectively contact more vertical pore space in relatively thicker geologic formations. Inter-site plume management (or cooperative) wells for the purpose of pressure monitoring and plume management may become the responsibility of a consortium of operators or a government entity, not individual sequestration site operators. (C) 2010 Published by Elsevier Ltd.
引用
收藏
页码:4238 / 4245
页数:8
相关论文
共 50 条
  • [1] CO2 Sequestration in Saline Formation
    Soong, Yee
    Howard, Bret H.
    Hedges, Sheila W.
    Haljasmaa, Igor
    Warzinski, Robert P.
    Irdi, Gino
    McLendon, Thomas R.
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2014, 14 (02) : 522 - 532
  • [2] The Application of an Integrated Earth Model in Reservoir Management of a CO2 Plume
    Leetaru, Hannes E.
    Smith, Valerie
    Will, Robert
    Freiburg, Jared
    Brown, Alan L.
    [J]. 12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 2903 - 2910
  • [3] CO2 Sequestration in Saline Water: An Integral Part of CO2 Sequestration in a Geologic Formation
    Hosein, R.
    Alshakh, S.
    [J]. PETROLEUM SCIENCE AND TECHNOLOGY, 2013, 31 (23) : 2534 - 2540
  • [4] Sequestering CO2 as CO2 hydrate in an offshore saline aquifer by reservoir pressure management
    Zhang, Kai
    Lau, Hon Chung
    [J]. ENERGY, 2022, 239
  • [5] Characteristics of CO2 sequestration in saline aquifers
    Shari Dunn-Norman
    David Wronkiewicz
    [J]. Petroleum Science, 2010, (01) : 83 - 92
  • [6] Characteristics of CO2 sequestration in saline aquifers
    Yang Fang
    Bai Baojun
    Tang Dazhen
    Dunn-Norman, Shari
    Wronkiewicz, David
    [J]. PETROLEUM SCIENCE, 2010, 7 (01) : 83 - 92
  • [7] Analysis of the Storage Capacity for CO2 Sequestration of a Depleted Gas Condensate Reservoir and a Saline Aquifer
    Barrufet, M. A.
    Bacquet, A.
    Falcone, G.
    [J]. JOURNAL OF CANADIAN PETROLEUM TECHNOLOGY, 2010, 49 (08): : 23 - 31
  • [8] Reservoir characteristics of the Bass Islands dolomite in Otsego County, Michigan: Results for a saline reservoir CO2 sequestration demonstration
    Harrison III, William B.
    Grammer, G. Michael
    Barnes, David A.
    [J]. Environmental Geosciences, 2009, 16 (03) : 139 - 151
  • [9] Subsurface CO2 Sequestration using Saline Aquifiers
    不详
    [J]. CHEMICAL ENGINEERING PROGRESS, 2010, 106 (06) : 15 - 15
  • [10] Continental Saline Aquifers Suitable for CO2 Sequestration
    SONG Jianlan
    [J]. Bulletin of the Chinese Academy of Sciences, 2013, 27 (01) : 26 - 27